Background: Tooth extraction is one of the most commonly performed procedures in dentistry. It is usually a traumatic process often resulting in immediate destruction and loss of alveolar bone and surrounding soft tissues. Various instruments have been described to perform atraumatic extractions which can prevent damage to the paradental structures. The physics forceps is one of those innovations in dental extraction technologies that claim to provide an efficient means for atraumatic dental extractions. Materials and method: A randomized clinical trial was conducted to compare the physics forceps with the conventional forceps for the removal of 28 mandibular single rooted teeth under the following parameters: incidence of crown, root, buccal alveolar bone fracture, the incidence of gingival tear and time needed for extraction. The samples were assigned randomly into two groups according to the computer based randomization software, into a control group (A) and study group (B). The control group was subjected to the surgical extraction procedure using the conventional forceps while the study group was subjected to the surgical extraction procedure using the physics forceps. Results: results showed that the time required for extraction using the physics forceps was (mean 0.385 min.), which was significantly lesser as compared with that of conventional forceps (mean 3.971 min.) (P=0.011), buccal bone fracture occurred in 4 out of 14 cases (28.57%) using the conventional forceps while it did not occur with the use of the physics forceps (0.00%), crown fracture occurred in 3 cases using the conventional forceps (21.43%), while it did not occur with the use of the physics forceps (0.00%), root fracture occurred in 1 case using the physics forceps (3.57%), while it did not occur with the use of the conventional forceps (0.00%). As for the gingival tear, it occurred in 7 cases using the conventional forceps (50.00%), while it did not occur with the use of the physics forceps (0.00%) which was highly significant (P=0.006). Conclusions: the use of physics forceps maintains the integrity of gingiva and surrounding periodontium. So extractions using physics forceps are less invasive over conventional forceps and can be considered as a reliable method for extraction requiring significantly less comparative intraoperative time.
The research aims to measure, assess and evaluate the efficiency of the directorates of Anbar Municipalities by using the Data Envelopment Analysis method (DEA). This is because the municipality sector is consider an important sector and has a direct contact with the citizen’s life. Provides essential services to citizens. The researcher used a case study method, and the sources of information collection based on data were monthly reports, the research population is represented by the Directorate of Anbar Municipalities, and the research sample consists of 7 municipalities which are different in terms of category and size of different types. The most important conclusion reached by the research i
... Show MoreThe industrial production sector has an important role in the national economy of the advanced countries as well as the developing ones to get higher levels for their economy . We in Iraq , just like most of the develpoing countries , our economy still suffers of great shortage in this active sector in spite of the repeated statements about the desire of activating the contribution of this sector in the national economy . The industrial sector in Iraq suffers in general of many problems , especially the public industrial sector (manufacturing) . These problems have been existed because of the unnatural conditions that Iraq has passed during the previous decades especially in the political and security sides . which reflecte
... Show MoreBackground: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16
... Show MoreBackground: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s
... Show MoreTigris River is the lifeline that supplies a great part of Iraq with water from north to south. Throughout its entire length, the river is battered by various types of pollutants such as wastewater effluents from municipal, industrial, agricultural activities, and others. Hence, the water quality assessment of the Tigris River is crucial in ensuring that appropriate and adequate measures are taken to save the river from as much pollution as possible. In this study, six water treatment plants (WTPs) situated on the two-banks of the Tigris within Baghdad City were Al Karkh; Sharq Dijla; Al Wathba; Al Karama; Al Doura, and Al Wahda from northern Baghdad to its south, that selected to determine the removal efficiency of turbidity and
... Show MoreArtificial roughness on the absorber plate of a Solar Air Heater (SAH) is a popular technique for increasing its effective efficiency. The study investigated the effect of geometrical parameters of discrete multi-arc ribs (DMAR) installed below the SAH absorber plate on the effective efficiency. The effects of major roughness factors, such as number of gaps (Ng = 1-4), rib pitch (p/e = 4-16), rib height (e/D = 0.018-0.045), gab width (wg/e = 0.5-2), angle of attack ( = 30-75), and Reynolds number (Re= 2000-20000) on the performance of a SAH are studied. The performance of the SAH is evaluated using a top-down iterative technique. The results show that as Re rises, SAH-effective DMAR's efficiency first ascends to a specified value o
... Show MoreBackground: Bimaxillary protrusion is considered as one of the most important causes to seek the orthodontic treatment to get better esthetics. This study aimed to test the effect of orthodontic treatment in improvement the facial esthetics. Materials and Methods: Ten Iraqi Arab females having bimaxillary protrusion based on Class I malocclusions treated with fixed orthodontic appliance and extraction of the maxillary and mandibular 1st permanent premolars. Pre and post-treatment facial profile photographs were taken for each patients and the effect of treatment was tested in comparison with the pre-treatment photographs by using seven angular measurements. Results: After treatment, the upper and lower lip projections were decreased signifi
... Show More