Background: Tooth extraction is one of the most commonly performed procedures in dentistry. It is usually a traumatic process often resulting in immediate destruction and loss of alveolar bone and surrounding soft tissues. Various instruments have been described to perform atraumatic extractions which can prevent damage to the paradental structures. The physics forceps is one of those innovations in dental extraction technologies that claim to provide an efficient means for atraumatic dental extractions. Materials and method: A randomized clinical trial was conducted to compare the physics forceps with the conventional forceps for the removal of 28 mandibular single rooted teeth under the following parameters: incidence of crown, root, buccal alveolar bone fracture, the incidence of gingival tear and time needed for extraction. The samples were assigned randomly into two groups according to the computer based randomization software, into a control group (A) and study group (B). The control group was subjected to the surgical extraction procedure using the conventional forceps while the study group was subjected to the surgical extraction procedure using the physics forceps. Results: results showed that the time required for extraction using the physics forceps was (mean 0.385 min.), which was significantly lesser as compared with that of conventional forceps (mean 3.971 min.) (P=0.011), buccal bone fracture occurred in 4 out of 14 cases (28.57%) using the conventional forceps while it did not occur with the use of the physics forceps (0.00%), crown fracture occurred in 3 cases using the conventional forceps (21.43%), while it did not occur with the use of the physics forceps (0.00%), root fracture occurred in 1 case using the physics forceps (3.57%), while it did not occur with the use of the conventional forceps (0.00%). As for the gingival tear, it occurred in 7 cases using the conventional forceps (50.00%), while it did not occur with the use of the physics forceps (0.00%) which was highly significant (P=0.006). Conclusions: the use of physics forceps maintains the integrity of gingiva and surrounding periodontium. So extractions using physics forceps are less invasive over conventional forceps and can be considered as a reliable method for extraction requiring significantly less comparative intraoperative time.
Goal of research is to investigate the impact of the use of effective learning model in the collection of the fourth grade students/Department of physics in the material educational methods and the development of critical thinking .to teach this goal has been formulated hypothesis cefereeten zero subsidiary of the second hypothesis .To investigate the research hypothesis were selected sample of fourth-grade students of the department of physics at the univers
... Show MoreThe current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we
... Show MoreThe current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % were
... Show MoreThere many methods for estimation of permeability. In this Paper, permeability has been estimated by two methods. The conventional and modified methods are used to calculate flow zone indicator (FZI). The hydraulic flow unit (HU) was identified by FZI technique. This technique is effective in predicting the permeability in un-cored intervals/wells. HU is related with FZI and rock quality index (RQI). All available cores from 7 wells (Su -4, Su -5, Su -7, Su -8, Su -9, Su -12, and Su -14) were used to be database for HU classification. The plot of probability cumulative of FZI is used. The plot of core-derived probability FZI for both modified and conventional method which indicates 4 Hu (A, B, C and D) for Nahr Umr forma
... Show MoreBackground : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome. Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ultrasonogr
... Show MoreBackground: The purpose of this study is to compare the color changes between the bonded middle third and the unbonded gingival and incisal thirds, fallowing fixed orthodontic treatment Material and method: The color parameter l, a, b has been recorded for each thirds in upper anterior teeth by mean of easy shad device. The has been calculated for gingival, middle and incisal thirds for the upper anterior teeth in 34 patient, 17 males and 17femals, those subject undergone fixed orthodontic treatment Results: The in middle bonded third is highly significant higher than that in incise and gingival thirds p<0.01 because the middle third isn’t expose to oral fluid and dental brushing since it covered by the bracket. Also there
... Show MoreMany behavioral researchers pointed out the importance of relaxation techniques in the treatment of different psychological disorders where find the importance of these techniques in reducing anxiety and stress and the resulted of behaviors and habits, with the development of these techniques are being used to gain public health, whether mental health or physical or mentality, and one of these techniques is music therapy that reduces tension and anxiety and operates a state of relaxation, which is used in the treatment of patients of dental clinic.
Re
... Show MoreBackground: Primary healthcare in Egypt has undergone significant reforms since the 1990s, including the pioneering Family Health Program (FHP). However, limited evaluation exists regarding the FHP's impact on enhancing the delivery of primary healthcare services. The primary objective of this study was to analyze and understand the efficiency and effectiveness of the FHP in altering the delivery of primary healthcare in Egypt. We aimed to outline the fundamental characteristics of the primary healthcare system, compare them between the conventional and the newly reformed FHP centers, and gauge the awareness level of these variances among key decision-makers, focusing specifically on Cairo, Egypt. Methods: This cross-sectional study employe
... Show MoreChoosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show More
