Background: This study was done to assist X-ray diffraction and biocompatability of glass ionomer cement reinforced by different ratios of Hydroxyapatite. Materials and Methods: The powder of glass ionomer cement reinforced by different ratios of Hydroxyapatite were used to get X-ray diffraction pattern by X-ray diffraction machine, While for biocompatibility test, A polyethylene tubes containing glass ionomer cement reinforced by different ratios of Hydroxyapatite were implanted on the dorsal submucosal site of Rabbit's tissues and histological slide were prepared for histopathological study. Results: X-ray diffraction test showed that all elements of glass ionomer cement reinforced by different ratios of Hydroxyapatite were react with each other and all the final products none crystalline in nature with small amount of Hydroxyapatite present unreacted may be act as cores for final reacted elements. The histological test showed mild irritation to Rabbit's tissues by glass ionomer cement reinforced by different ratios of Hydroxyapatite, this irritation subsided with time. Conclusions: there is chemical reaction of all elements of glass ionomer cement reinforced by different ratios of Hydroxyapatite and new final products were results .Also glass ionomer cements reinforced by different ratios of Hydroxyapatite were biocompatible with Rabbit’s tissues.
Practically, torsion is normally combined with flexure and shear actions. Even though, the behavior of reinforced concrete continuous beams under pure torsion is investigated in this study. It was performed on four RC continuous beams under pure torsion. In order to produce torsional moment on the external supports, an eccentric load was applied at various distances from the longitudinal axis of the RC beams until failure.
Variables considered in this study are absolute vertical displacement of the external supports, torsional moment’s capacity, angle of twist and first cracks occurrences. According to experimental results; when load eccentricity increased from 30cm to 60cm, the absolute vertical displacement i
... Show MoreThe study focused on examining the behavior of six concrete beams that were reinforced with glass fiber-reinforced polymer (GFRP) bars to evaluate their performance in terms of their load-carrying capacity, deflection, and other mechanical properties. The experimental investigation would provide insights into the feasibility and effectiveness of GFRP bars as an alternative to traditional reinforcement materials like steel bars in concrete structures. The GFRP bars were used in both the longitudinal and transverse directions. Each beam in the study shared the following specifications: an overall length of 2,400 mm, a clear span of 2,100 mm, and a rectangular cross-section measuring
Hand-lay up method was used to prepare the samples made of epoxy (EP) as a matrix reinforced with chopped carbon fibers (CCF). The fatigue behavior of epoxy resin /chopped carbon fiber composites was studied with different weight percentage of chopped carbon fibers (2.5%,5%,7.5%,10%,12.5%). The fatigue test was carried out under alternate bending method, which was made by applying sinusoidal wave with constant displacement (15mm), stress ratio R=-1,and loading frequency 10Hz, which is believed to give a negligible temperature rise during the test. The results of the maximum stress, fatigue strength, fatigue limit and fatigue life of the tested composites are calculated from stress(S)-number of cycles(N) (S-N) curves.
It was shown that
Overlapped have been prepared from epoxy resin material added to carbon Nanotube and percentages weight (0.1, 0.05, 0.01) % Studied the mechanical properties of the composite (bending, tensile an d hardness) has been found that the Flexural and tensile modulus of the composites were higher than the pure epoxy resin this may be due to the high mechanical strength of carbon nano tube (CNT). The hardness of the epoxy carbon Nanotube composites increased and the reason is due to increased overlap and stacking between the additives and material basis, which reduces the movement of polymer molecules leading to increased resistance to scratching material and cutting, will become more resistance to plastic deformation.
Objective. Glass-ionomer and resin-modified glass-ionomer cements are versatile materials with the ability to form a direct bond with tooth tissues. The aim of this study was to formulate a novel class of dental bio-interactive restorative material (pRMGIC) based on resin-modified glass-ionomer cements via the inclusion of an organophosphorus monomer, ethylene glycol methacrylate phosphate, with a potential to improve the mechanical properties and also function as a reparative restorative material. Methods. pRMGIC was formulated with modification of the resin phase by forming mixes of ethylene glycol methacrylate phosphate (EGMP; 0–40%wt) and 2-hydroxyethyl methacrylate monomer into the liquid phase of a RMGIC (Fuji II LC, GC Corp.).
... Show MoreMixed ligand complexes of bivalent metal ions, viz; M= Fe(II),Co(II),Ni(II),Cu(II), Zn(II), Cd (II), and Hg(II) of the composition Na2[M (Amox)(Sac)3] in 1:1:3 molar ratio, (where Amox = Amoxicillin tryhydrate (C16H19N3O5S.H2O) and Sac = Saccharine(C7H5NO3S) have been synthesized and characterized by repeated melting point determination, Solubility, Molar conductivity, determination the percentage of the metal in the complexes by flame(AAS), FT-IR, magnetic susceptibility measurements and electronic spectral data. The ligands and their metal complexes have been screened for their biological activity against selected microbial strains (gram +ve) and (gram -ve).
Mixed ligand complexes of bivalent metal ions, viz; M= Fe(II),Co(II),Ni(II),Cu(II), Zn(II), Cd (II), and Hg(II) of the composition Na2[M (Amox)(Sac)3] in 1:1:3 molar ratio, (where Amox = Amoxicillin tryhydrate (C16H19N3O5S.H2O) and Sac = Saccharine(C7H5NO3S) have been synthesized and characterized by repeated melting point determination, Solubility, Molar conductivity, determination the percentage of the metal in the complexes by flame(AAS), FT-IR, magnetic susceptibility measurements and electronic spectral data. The ligands and their metal complexes have been screened for their biological activity against selected microbial strains (gram +ve) and (gram -ve).