Background: The aim of this study was for estimation and comparism of masticatory efficiency in patient wearing heat cured acrylic and flexible base partial denture, finding out the role of peanuts and carrots on the measurement of chewing efficiency, and to find out whether the types of P.D. (being single or two opposing each other) has any effect on the masticatory performance. Materials and methods: Twenty partially edentulous patients were selected. Five of these patients were selected having Kennedy class I with no modification against natural dentition, other 5patients having Cl.I against Cl.I . The other 5 patients having Cl.III against natural dentition and the last 5 patients were with Cl.III against Cl.III. several ways were used for measuring masticatory efficiency including: number of chewing strokes, number of swallows, the mastication time, and measure the masticatory performance by sieving method. Differences between the means of the four groups were analyzed with t-test. Results: The differences between the two denture base types in total number of strokes was significant at (p<0.001) in study group (2,3,4), the study group (4)have the highest mean value of the total number of strokes for acrylic denture during chewing carrots food types(47.6)strokes. The highest mean value of the total chewing time is for the fourth group with the acrylic denture during chewing carrots (35.2 sec.), and the highest masticatory performance index was for the flexible denture in all study groups during chewing the two tested food. Conclusion: The flexible partial denture provide better chewing efficiency than heat cure acrylic partial denture, the masticatory performance was higher for flexible partial denture than heat cure acrylic partial denture, there was significant differences between carrots and peanuts in both flexible and heat cure acrylic partial denture, and patient with single denture show better chewing efficiency than patient with paired denture.
Objectives: To assess the performance of a novel resin-modified glass-ionomer cement (pRMGIC) bonded to various tooth tissues after two-time intervals. Methods: 192 sound human molars were randomly assigned to 3 groups (n = 64): sound enamel, demineralised enamel, sound dentine. Sixty-four teeth with natural carious lesions including caries-affected dentine (CAD) were selected. All substrates were prepared, conditioned and restored with pRMGIC (30% ethylene glycol methacrylate phosphate (EGMP, experimental), Fuji II LC (control), Fuji IX, and Filtek™ Supreme with Scotchbond ™ Universal Adhesive. Shear bond strength (SBS) was determined after 24 h and three months storage in SBF at 37C. The debonded surfaces were examined using stereomi
... Show MoreThis study has been done for testing the effectiveness and efficiency of probiotic in its ability to inhibit Aspergillus flavus , which secretes the aflatoxin B1 and compare it with materials that were approved to be effective in the inhibition of the growth of fungi and break down and reduction of mycotoxin. these are the filax substance and ozone gas. A laboratory experiment has been conducted to determine the isolates out of the fungus producing the aflatoxin B1.the isolate producing aflatoxin B1 has grown on the yellow corn seed. the probiotic was added along with the filax and they have been exposed to ozone gas and then they were stored from 30 days. A bio test was con conducted to knw the effects of biological toxin on the broiler me
... Show MoreAbstract
Antibiotic treatment of S.typhi is difficult as compared to treatment of acute infection. Antibiotic resistance carried against S.typhi by using 6 kinds of antibiotics from different classes, their results showed that all isolates were high resistance to Ampicillin (99%), Gentamicin (98%), Amikacin (79%) and less resistances Trimethoprim (55%) , Imipenem (60%) and Ceftriaxone(66%) .
The present study focused on the molecular detection of Wzx flippase, Wzy polymerase genes in some Salmonella typhi isolates, Samples were collected from typhoid patients by classical lab work. Antibiotics susceptibilit
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreExperimental tests were carried to control lost circulation in the Khabaz oil field using different types of LCMs including Nano-materials. A closed-loop circulation system was built to simulate the process of lost circulation into formations. Two dolomite plugs were used from different depths of the formation of Azkand in Khabaz oil field. The experimentations were carried out to study the effect of different types of LCMs, cross-linked copolymer (FLOSORB CE 300 S), SiO2 NP, and Fe2O3 NP, on mud volume losses as a function of time.
The rheological measurements of the nanoparticles-reference mud system showed that both of the SiO2 NP and Fe2O3 NP w
... Show MoreBackground: to evaluate the effect of different dentifrices on the surface roughness of two composite resins (nanofilled-based and nanoceramic – based composite resins). Materials and methods: Forty specimens (diameter 12 mm and height of 2mm) prepared from different composite resin materials: Z350 (nanofilled composite, and Ceram-X (nanoceramic) .they were subjected to brushing simulation equivalent to the period of 1 year. The groups assessed were a control group brushed with distilled water (G1), Opalescence whitening toothpasteR (G2), Colgate sensitive pro-relief (G3) and Biomed Charcoal Toothpaste (G4). The initial and final roughness of each group was tested by surface roughness tester. The results were statistically analyzed using
... Show MoreThe research is dealing with the absorption and fluorescence spectra for the hybrid of an Epoxy Resin doped with organic dye Rhodamine (R6G) of different concentrations (5*10-6, 5*10-5, 1*10-5, 1*10-4, 5*10-4) Mol/ℓ at room temperature. The Quantum efficiency Qfm, the rate of fluorescence emission Kfm (s-1), the non-radiative lifetime τfm (s), fluorescence lifetime τf and the Stokes shift were calculated. Also the energy gap (Eg) for each dye concentration was evaluated. The results showed that the maximum quantum effi
... Show MoreBackground: Crown preparation of vital teeth involve the removal of a sound tooth structure, and when enamel removed this lead to exposed dentin with an increase in the number of open dentinal tubules also the diameter of dentinal tubules will increase, furthermore lead to increase movement of fluids inside the tubules all that causes post preparation sensitivity. The aim of this study is to evaluate the effect of desensitizing by Er:Cr:YSGG laser on shear bond strength of prepared tooth and resin cement. Materials and methods: Thirty sound maxillary premolars, grouped into three groups(n=10). Group A is the control group, group B irradiated by Er:Cr:YSGG laser with (0.25 W, 20 Hz, 1
... Show MoreThe experiment aimed to Manufacture a device for checking the nozzles and testing its efficiency and to study the effect of research factors on the studied traits. The device was manufactured locally through using materials available in the Iraqi market. The system is Both Hydraulic and electronic (ISO 5682-1)1 relay on sensors technology and the test platform was built and designed on a movable trolly at the department of Agricultural Machines and Equipment / College of Agricultural Science / University of Baghdad. The design includes the use of mechanical water pump and electrical AC water pump. The design includes a nozzle holder that can accommodate three nozzles per test. The design also consists of spreading wings and stationa
... Show More