Preferred Language
Articles
/
jbcd-259
Clinical evaluations for the masticatory efficiency of heat cure resin and flexible types of denture base materials
...Show More Authors

Background: The aim of this study was for estimation and comparism of masticatory efficiency in patient wearing heat cured acrylic and flexible base partial denture, finding out the role of peanuts and carrots on the measurement of chewing efficiency, and to find out whether the types of P.D. (being single or two opposing each other) has any effect on the masticatory performance. Materials and methods: Twenty partially edentulous patients were selected. Five of these patients were selected having Kennedy class I with no modification against natural dentition, other 5patients having Cl.I against Cl.I . The other 5 patients having Cl.III against natural dentition and the last 5 patients were with Cl.III against Cl.III. several ways were used for measuring masticatory efficiency including: number of chewing strokes, number of swallows, the mastication time, and measure the masticatory performance by sieving method. Differences between the means of the four groups were analyzed with t-test. Results: The differences between the two denture base types in total number of strokes was significant at (p<0.001) in study group (2,3,4), the study group (4)have the highest mean value of the total number of strokes for acrylic denture during chewing carrots food types(47.6)strokes. The highest mean value of the total chewing time is for the fourth group with the acrylic denture during chewing carrots (35.2 sec.), and the highest masticatory performance index was for the flexible denture in all study groups during chewing the two tested food. Conclusion: The flexible partial denture provide better chewing efficiency than heat cure acrylic partial denture, the masticatory performance was higher for flexible partial denture than heat cure acrylic partial denture, there was significant differences between carrots and peanuts in both flexible and heat cure acrylic partial denture, and patient with single denture show better chewing efficiency than patient with paired denture.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 10 2022
Journal Name
Eurasian Chemical Communications
Detection of lead and cadmium in types of chips from local markets in Baghdad
...Show More Authors

View Publication
Scopus (1)
Scopus
Publication Date
Sun Apr 28 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
COMPARISON OF TWO TYPES OF SENSORS AND THEIR EFFECT ON SPRAY QUALITY PEAR TREES
...Show More Authors

This study was aimed to reduce the amount of the sprayed solution lost during trees spraying.  At the same time, the concentration of the sprayed solution on the target (tree or bush) must be ensured and to find the best combination of treatments. Two factors controls the spraying process: (i) spraying speed (1.2 km/h, 2.4 km/h, 3.6 km/h), and (ii) the type of sensor. The test results showed a significant loss reduction percentage. It reached (6.05%, 5.39% and 2.05%) at the speed (1.2 km/h, 2.4 km/h, 3.6 km/h), respectively. It was noticed that when the speed becomes higher the loss becomes less accordingly. The interaction between the 3.6 km/h speed and the type of Ultrasonic sensor led to a decrease in the percentage of the spray

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
THE PREVALENCE AND CLINICAL SIGNIFICANCE OF PERINUCLEAR ANTINEUTROPHIL CYTOPLASMIC ANTIBODY IN PATIENTS WITH INDETERMINATE COLITIS
...Show More Authors

Background: Indeterminate colitis (IC), a term
originated by pathologists to characterize confounding
histopathlogic appearance of resected mucosa, has
become catch phrase for cases in which diagnostic
criteria at all levels elude classification as Crohn's
disease (CD) or ulcerative colitis (UC).
OBJECTIVES: evaluate the prevalence of pANCA
expression in the sera and its isotypes.
Patients and methods: PATIENTS GROUP
consisted of 60 patients (40 males and 20 females)
with indeterminate colitis and their age range was (19-
84 years). CONTROL GROUP consisted of 30 (15
males and 15 females) healthy volunteers and their
age range was (20- 66 years).
Antineutrophil cytoplasmic ( pANCA and cANCA)
te

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Soft Tissue Changes Following Orthodontic Treatment of Bimaxillary Protrusion (A Clinical and Photographical Study)
...Show More Authors

Background: Bimaxillary protrusion is considered as one of the most important causes to seek the orthodontic treatment to get better esthetics. This study aimed to test the effect of orthodontic treatment in improvement the facial esthetics. Materials and Methods: Ten Iraqi Arab females having bimaxillary protrusion based on Class I malocclusions treated with fixed orthodontic appliance and extraction of the maxillary and mandibular 1st permanent premolars. Pre and post-treatment facial profile photographs were taken for each patients and the effect of treatment was tested in comparison with the pre-treatment photographs by using seven angular measurements. Results: After treatment, the upper and lower lip projections were decreased signifi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 30 2024
Journal Name
The Scientific World Journal
Relationship Between the Level of Vitamin D3 Deficiency and Successful Osseointegration: A Prospective Clinical Study
...Show More Authors

Purpose: This study aimed to evaluate the influence of vitamin D3 levels on bone density, primary dental implant stability, and successful osseointegration.

Materials and Methods: Clinical and radiological examination with a standardized cone‐beam computed tomography (CBCT) machine and laboratory investigation for serum levels of vitamin D3 were performed for all patients. Only patients in need of single or multiple straightforward dental implant surgery in either jaw with no history of systemic disease or condition that may interfere with bone healing were included in this study to receive the dental implant by the same oral and maxillofacial surgeon, which re‐opened

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Mon Sep 30 2024
Journal Name
The Scientific World Journal
Relationship Between the Level of Vitamin D3 Deficiency and Successful Osseointegration: A Prospective Clinical Study
...Show More Authors

Purpose: This study aimed to evaluate the influence of vitamin D3 levels on bone density, primary dental implant stability, and successful osseointegration.

Materials and Methods: Clinical and radiological examination with a standardized cone‐beam computed tomography (CBCT) machine and laboratory investigation for serum levels of vitamin D3 were performed for all patients. Only patients in need of single or multiple straightforward dental implant surgery in either jaw with no history of systemic disease or condition that may interfere with bone healing were included in this study to receive the dental implant by the same oral and maxillofacial surgeon, which re‐opened

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Fri Jul 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of various endodontic irrigants on the sealing ability of Biodentine and other root perforation repair materials (In vitro study)
...Show More Authors

Background: This in vitro study was carried out to evaluate the effect of various endodontic irrigants (sodium hypochlorite, ethylene diaminetetracetic acid and normal saline) on sealing ability of (Biodentine, mineral trioxide aggregate, and amalgam) used to repair furcal perforations. Material and methods: One hundred and twenty extracted human molars with divergent roots were used in this study. A standard root canal access cavity was prepared in each tooth and furcal perforation was made and was standardized by using k file size 100 instrument to get a perforation of (1.32mm) in diameter .The teeth were randomly divided in to three groups of 40 teeth according to the type of material used to repair the perforations (Group A: The furcal

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 15 2022
Journal Name
Al-academy
The Relationship Between Using Diverse Materials to the Intellectual Context's in the Art of Contemporary Ceramic
...Show More Authors

The use of different materials in the art of ceramics is considered a new form of contemporary philosophical trends. That was introduced to art as a result of societal changes and transformations and rapid technological development. And it plays a very essential part in the beauty of the artistic structure. The contrast of using different materials in ceramics is considered a part of the old historical achievements since the art of ceramics used to follow strict standards. Which does not apply to contemporary ceramic, Because recently, it has become free from any religious and social control and created a whole new intellectual context, heading to new horizons in which it works with the newly added materials as a strategy to ensure the a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Heat Transfer of Single and Binary Systems in Pool Boiling
...Show More Authors

The present research focuses on the study of the effect of mass transfer resistance on the rate of heat transfer in pool boiling. The nucleate pool boiling heat transfer coefficients for binary mixtures (ethanol-n-butanol, acetone-n-butanol, acetone-ethanol, hexane-benzene, hexane-heptane, and methanol-water) were measured at different concentrations of the more volatile components. The systems chosen covered a wide range of mixture behaviors.

The experimental set up for the present investigation includes electric heating element submerged in the test liquid mounted vertically. Thermocouple and a digital indictor measured the temperature of the heater surface. The actual heat transfer rate being obtained by multiplying the voltme

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Entropy Generation of Shell and Double Concentric Tubes Heat Exchanger
...Show More Authors

Entropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger). Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Final

... Show More
View Publication Preview PDF