Preferred Language
Articles
/
jbcd-259
Clinical evaluations for the masticatory efficiency of heat cure resin and flexible types of denture base materials
...Show More Authors

Background: The aim of this study was for estimation and comparism of masticatory efficiency in patient wearing heat cured acrylic and flexible base partial denture, finding out the role of peanuts and carrots on the measurement of chewing efficiency, and to find out whether the types of P.D. (being single or two opposing each other) has any effect on the masticatory performance. Materials and methods: Twenty partially edentulous patients were selected. Five of these patients were selected having Kennedy class I with no modification against natural dentition, other 5patients having Cl.I against Cl.I . The other 5 patients having Cl.III against natural dentition and the last 5 patients were with Cl.III against Cl.III. several ways were used for measuring masticatory efficiency including: number of chewing strokes, number of swallows, the mastication time, and measure the masticatory performance by sieving method. Differences between the means of the four groups were analyzed with t-test. Results: The differences between the two denture base types in total number of strokes was significant at (p<0.001) in study group (2,3,4), the study group (4)have the highest mean value of the total number of strokes for acrylic denture during chewing carrots food types(47.6)strokes. The highest mean value of the total chewing time is for the fourth group with the acrylic denture during chewing carrots (35.2 sec.), and the highest masticatory performance index was for the flexible denture in all study groups during chewing the two tested food. Conclusion: The flexible partial denture provide better chewing efficiency than heat cure acrylic partial denture, the masticatory performance was higher for flexible partial denture than heat cure acrylic partial denture, there was significant differences between carrots and peanuts in both flexible and heat cure acrylic partial denture, and patient with single denture show better chewing efficiency than patient with paired denture.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 13 2018
Journal Name
Mustansiria Dental Journal
Dimensional stability of heat-activated acrylic resin at different time intervals by different flask cooling methods
...Show More Authors

This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an

... Show More
Preview PDF
Publication Date
Fri Jun 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
A Study the Effect of Addition of Silanized Zirconium Oxide Nanoparticles on Some Properties of High-Impact Heat-Cured Acrylic Resin
...Show More Authors

Background: The incorporation of rubber has not been entirely successful because it can have detrimental effects on the transverse Strength and hence the rigidity of the denture base. Materials and methods: Zirconium oxide nanoparticales were coated with a layer of trimethoxysilylpropylmethacrylate (TMSPM) before sonication in monomer (MMA) with the percentages 3% by weight then mixed with powder using conventional procedure.(100) samples were prepared and divided into five groups according to the test performed ,Each group consisted of 20 specimens and these were subdivided into 2 groupsGroup (A): control group (10 specimens of high impact acrylic resin without zirconium oxide) and Group (B):zirconium oxide group(10 specimens of high impac

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
International Journal Of Mechanical Engineering And Technology (ijmet)
MANUFACTURING AND ANALYSIS CUSTOM FOOT ORTHOTIC FOR FLEXIBLE FLATFOOT
...Show More Authors

This paper presents two main parts: The first part involves manufacturing the specimens form composite material for mechanical testing (tensile, flexural and fatigue tests), then design a custom foot orthesis (CFO) and manufacturing from composite lamination (3nylglass 2carbon fiber 3nylglass) for patient suffer from flexible flat foot since birth and over-pronation. The second part of this research involves a design a model of custom foot orthesis in (solid work 2018) and then analysis of custom foot orthosis in engineering analysis program (ANSYS V.18.2).The applied pressure in boundary condition adopted from Force Sensor Resistance (FSR 402 ) in various regions in foot after wearing composite CFO. Used a composite materials in engineerin

... Show More
View Publication
Scopus (2)
Scopus
Publication Date
Fri Jun 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [part II]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [Part I]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation the effect of nano-fillers (TiO2, AL2O3, SiO2) addition on glass transition temperature, E-Moudulus and coefficient of thermal expansion of acrylic denture base material
...Show More Authors

Background: The PMMA polymer denture base materials are low in thermal and strength properties. The aim of the study was to investigate the change in glass transition temperature, E-Moudulus and coefficient of thermal expansion of acrylic denture base material by addition of Al2O3, TiO2 and SiO2nano-fillers in 5% by weight. Materials and methods: The type of polymerization is free radical bulk polymerization. one hundred twenty (120) specimens were prepared , the specimens were divided into four groups according to the material had been added (one control and three for Al2O3, TiO2 and SiO2nanocomposite) each group was subdivided in to three groups according to the test had been done on it, the degree of transition (Tg) was measured by The d

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 03 2025
Journal Name
Journal Of Molecular Structure
Synergistic design of carbazole-bearing (D–π)₂-D–π–A architectures for dye-sensitized solar cells: Experimental and theoretical evaluations
...Show More Authors

Publication Date
Thu Apr 30 2026
Journal Name
International Journal Of Engineering Pedagogy (ijep)
The Impact of Intelligent Adaptive Learning on Flexible Thinking and Academic Achievement for Undergraduate Students
...Show More Authors

In the knowledge society, artificial intelligence (AI) forms a cornerstone of global education. This quasi-experimental study examines the impact of an Intelligent Adaptive Learning Strategy (IALS) on flexible thinking (FT) and academic achievement among 60 3rd-year undergraduate students at the College of Education/University of Baghdad (experimental n = 30; control n = 30). The IALS was implemented via an AI-supported educational platform, while the control group received conventional instruction. Post-test intervention assessments included an FT test (10 items, content validity = 0.89, Cronbach’s α = 0.87) and an achievement test (10 objective items, α = 0.85). Results revealed statistically significant superiority of the exp

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Nov 01 2011
Journal Name
Iraqi Journal Of Applied Physics
Calculation of the Buildup Factors for Ceramic Materials
...Show More Authors

Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
STUDY OF TEMPERATURE EFFECT ON THE HARDNESS FOR EPOXY RESIN AND UNSATURATED POLYESTER
...Show More Authors

This search aim to measure Hardness for Epoxy resin and for unsaturated Polyester resin as base materials for composite Hybrid and the materials used is Hybrid fiber Carbon-Kevlar. The Hand Lay-up method was used to manufacture plates of Epoxy resin (EP) and unsaturated Polyester EP,UPE backed by Hybrid fiber (Carbon-Kevlar) and with small volume fraction 5,10 and 15 for every there are Layer of fibers (1,2 and 3). The hardness test was count for material EP, UPE resin and there composites and that we notice that the Hardness (HB) decreased with increase of temperatures.

View Publication Preview PDF
Crossref