Preferred Language
Articles
/
jbcd-2580
Comparison between diode laser and scalpel for lip lengthening in patients with gummy smile
...Show More Authors

Background: lip lengthening procedure is one of the surgical options for the correction of gummy smile in patients with short upper lip. Methods: A comparative clinical study was conducted on 15 patients requiring lip lengthening procedure for the esthetic correction of excessive gingival exposure with gummy smile. Scalpel was used in seven patients and diode laser in the remaining eight patients. Under infiltration anesthesia, about one cm strip of mucosa was excised at the vestibular depth and the mucosa of the lip was sutured to the alveolar mucosa. Results: The diode laser group demonstrated less postoperative pain and swelling. Regarding postoperative ecchymosis, three patients in the scalpel group developed ecchymosis and no cases were noted in the laser group, the difference was statistically significant. No patient in the laser group developed wound dehiscence and only one patient in the scalpel group had wound dehiscence at third postoperative day. Observed at one month postoperatively, the laser treated groups had less obvious scar than the scalpel group. Conclusion: Diode laser is a valuable tool in performing lip lengthening for gummy smile.

Scopus Crossref
View Publication
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Gamma Irradiation Effects on Energy Transfer Parameters for Acrvlaven – Rhodamine19 Binary Laser Dye Mixtures
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed Jul 20 2022
Journal Name
Journal Of Materials Engineering And Performance
High Speed Shock Peening by Fiber Laser for Al Alloy 6061-T6 Thin Sheets
...Show More Authors

Under cyclic loading, aluminum alloys exhibit less fatigue life than steel alloys of similar strength and this is considered as Achilles's heel of such alloys. A nanosecond fiber laser was used to apply high speed laser shock peening process on thin aluminum plates in order to enhance the fatigue life by introducing compressive residual stresses. The effect of three working parameters namely the pulse repetition rate (PRR), spot size (ω) and scanning speed (v) on limiting the fatigue failure was investigated. The optimum results, represented by the longer fatigue life, were at PRR of 22.5 kHz, ω of 0.04 mm and at both v's of 200 and 500 mm/sec. The research yielded significant results represented by a maximum percentage increase in the fa

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Synthesis of gold nanoparticles by laser ablation on porous silicon for sensing CO2 gas
...Show More Authors

In this research, porous silicon (PS) prepared by anodization etching on surface of single crystalline p-type Si wafer, then Gold nanoparticle (AuNPs) prepared by pulsed laser ablation in liquid. NPs deposited on PS layer by drop casting. The morphology of PS, AuNPs and AuNPs/PS samples were examined by AFM. The crystallization of this sample was characterized by X-ray diffraction (XRD). The electrical properties and sensitivity to CO2 gas were investigated to Al/AuNPs/PS/c-Si/Al, we found that AuNPs plays crucial role to enhance this properties.

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Comparison study of CC and CH vibration frequencies and eelectronic properties for mono, Di, Tri, and tetra-rings layer of arm chair (SWCNTs)
...Show More Authors

Semi-empirical methods were applied for calculating the vibration frequencies and IR absorption intensities for normal coordinates of the {mono (C56H28), di (C84H28), tri (C112H28) and tetra (C140H28)} -rings layer for (7,7) armchair single wall carbon nanotube at their equilibrium geometries which were all found to have D7d symmetry point group.

Assignment of the modes of vibration (3N-6) was done depending on the pictures of their modes by applying (Gaussian 03) program. Comparison of the vibration frequencies of (mono, di, tri and tetra) rings layer which are active in IR, and inactive in Ramman spectra. For C-H stretching vibrat

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Ridge regression method with some classical methods to estimate the parameters of Lomax distribution by simulation
...Show More Authors

Abstract

In this research provide theoretical aspects of one of the most important statistical distributions which it is Lomax, which has many applications in several areas, set of estimation methods was used(MLE,LSE,GWPM) and compare with (RRE) estimation method ,in order to find out best estimation method set of simulation experiment (36) with many replications  in order  to get mean square error and used it to make compare , simulation experiment  contrast with (estimation method, sample size ,value of location and shape parameter) results show that estimation method effected by simulation experiment factors and ability of using other estimation methods such as(Shrinkage, jackknif

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 10 2022
Journal Name
European Scholar Journal (esj)
MODELING AND COMPARISON OF CLOSED-LOOP AND OPENLOOP ADAPTIVE OPTICS SYSTEMS
...Show More Authors

Astronomers have known since the invention of the telescope that atmospheric turbulence affects celestial images. So, in order to compensate for the atmospheric aberrations of the observed wavefront, an Adaptive Optics (AO) system has been introduced. The AO can be arranged into two systems: closedloop and open-loop systems. The aim of this paper is to model and compare the performance of both AO loop systems by using one of the most recent Adaptive Optics simulation tools, the Objected-Oriented Matlab Adaptive Optics (OOMAO). Then assess the performance of closed and open loop systems by their capabilities to compensate for wavefront aberrations and improve image quality, also their effect by the observed optical bands (near-infrared band

... Show More
View Publication
Publication Date
Thu Oct 01 2009
Journal Name
Journal
Perniosis: clinical and epidemiological study in Iraqi patients
...Show More Authors

AN Adil A, F Basman M, 2009

View Publication
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Physiological and Immunological Disturbance in Rheumatoid Arthritis Patients
...Show More Authors

            Rheumatoid arthritis (RA) is a systematic autoimmune disorder with chronic inflammation changes of unknown etiology. Various synovial inflammatory and proliferative alterations may contribute to the cartilaginous tissues and invasive bony tissues, leading to destructive joints and malformed bones. This disease is mostly due to infective microorganisms or genetic susceptibility causing immune system disturbances through triggering both T-cells and B-cells. Furthermore, different immune cells may secret cytokines, which are responsible for some RA pathogenesis activity. From ninety individuals, serum sample was collected; thirty of them were normal and sixty cases were patients with RA attended a privet medical clin

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Automatic Co-registration of UAV-Based Photogrammetry and Terrestrial Laser Scanning in Urban Areas
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Evaluation the Effects of CO2 Laser on Soft and Hard Tissues (in vitro study)
...Show More Authors

CO2 laser (10.6 μm) is the most often used laser in the oral surgery due to its high absorption by water of the oral tissues. Several benefits of the use of CO2 laser have been reported for oral surgical procedures. This study aims to evaluate the effect of CO2 laser on soft and hard oral tissues (in vitro study). This study was done on fresh tissues from sheep’s head. CO2Surgical Laser with different operation modes was used; 0.2 mm spot size using different laser parameters on the tongue, and bone making holes, incisions and cutting. The depths and widths of holes and incisions were measured using endodontic file under magnification. The speed of incisions was calculated and the required time for cutting was measured using sport clo

... Show More
View Publication Preview PDF