Preferred Language
Articles
/
jbcd-2574
The effect of 2 different techniques in second stage implant surgery
...Show More Authors

Background: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for the need of anesthesia. Duration of the procedure was calculated in each case and post-operative pain was assessed by Visual analogue scale at day 1 and day 7. Results: Statistically significant difference in the need of anesthesia was found. A non-significant difference in the duration of the operation was found between the two methods. Non-significant difference was found between the two methods regarding post-operative pain at day 1, with the day 7 scores "no pain or zero pain score" in all the cases by the two methods. A directional significant correlation was found between depth of the gingival tissue over the implants and duration of the procedures regardless of the method used. Conclusion: diode laser can be used effectively for uncovering implants, providing both the dentist and the patient with additional advantages over the conventional methods. Although there was insignificant difference in pain scoring, however implant exposure by laser was more preferred by the patients.

Scopus Crossref
View Publication
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Results and predictive factors for single level L4-5, and L5-S1 disc herniation surgery
...Show More Authors

Background: The disc prolapse is a common condition especially in young adults. Different levels are affected in the lumber region; the L4/L5 disc is more susceptible to longitudinal load and is the most common site of lumbar disc prolapse. The L5/S1 disc is protected from torsion load by strong ilio-lumbar ligaments but it is more susceptible to axial compressive forces. Many factors affect the result and outcome of surgery in these levels.Objective: The aim of this study is to correlate operative data, short-term results, complications, and prognostic factors (age, gender, mobility, hospital stay, and level of pain) for one-level lumber discectomybetween different levels (L4–L5 vs. L5–S1).Methods In this prospective study, 32 patie

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Cone Beam Computed Tomography in an Evaluation and Diagnosis of Anatomical Variations and Pathological Lesions in Maxillary Sinus Prior to Maxillary Sinus Lift Surgery
...Show More Authors

Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner re

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Heliyon
Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study)
...Show More Authors

Objectives: This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods: Sixty cylindrical specimens (5 mm diameter ×3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was tr

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Al-academy
Synthetic Sculpture Techniques in Outputs of Students of the Department of Art Education: أشراق علي خلف العزاوي
...Show More Authors

The research studies the synthetic sculpture techniques in the outputs of the students of the department of art education in terms of the shape, texture, content and technique, and employing this style by the students of the department of art education on the college of fine arts, university of Diyala. The research consists of four chapters: the first chapter: the research problem summarized by looking for the synthetic sculpture and its importance in the treatment the industrial wastes in our social life, according to modern synthetic techniques, in the American and European sculpture. This technique has been employed in more than one contemporary artistic direction and style.
This study is considered important for the students of t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Food Science And Technology
Evaluating the hydrophilic antioxidant capacity in different citrus genotypes
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Physical and Histological Evaluation of Coated Implant with Nano ZrO2 after Creation Titania Nanotubes
...Show More Authors

Background: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Aug 25 2023
Journal Name
Journal Of Composites Science
Powder Metallurgy Preparation and Characterization of Titanium-Titanium Diboride Composite Targeted for Dental Implant
...Show More Authors

Due to the advantages over other metallic materials, such as superior corrosion resistance, excellent biocompatibility, and favorable mechanical properties, titanium, its alloys and related composites, are frequently utilized in biomedical applications, particularly in orthopedics and dentistry. This work focuses on developing novel titanium-titanium diboride (TiB2; ceramic material) composites for dental implants where TiB2 additions were estimated to be 9 wt.%. In a steel mold, Ti-TiB2 composites were fabricated using a powder metallurgy technique and sintered for five hours at 1200 °C. Microstructural and chemical properties were analyzed by energy dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), and X-ra

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2017
Journal Name
Journal Of Craniofacial Surgery
Lateral Ridge Splitting (Expansion) With Immediate Placement of Endosseous Dental Implant Using Piezoelectric Device
...Show More Authors

View Publication
Crossref (18)
Crossref
Publication Date
Sun Oct 18 2020
Journal Name
Diagnostics
Diagnostic Accuracy of Oral Fluids Biomarker Profile to Determine the Current and Future Status of Periodontal and Peri-Implant Diseases
...Show More Authors

Severe periodontitis is ranked as the sixth most prevalent disease affecting humankind, with an estimated 740 million people affected worldwide. The diagnosis of periodontal diseases mainly relies upon assessment of conventional clinical parameters. However, these parameters reflect past, rather than current, clinical status or future disease progression and, likely, outcome of periodontal treatment. Specific and sensitive biomarkers for periodontal diseases have been examined widely to address these issues and some biomarkers have been translated as point-of-care (PoC) tests. The aim of this review was to provide an update on PoC tests for use in the diagnosis and management of periodontal diseases. Among the PoC tests developed so

... Show More
View Publication Preview PDF
Scopus (78)
Crossref (73)
Scopus Clarivate Crossref