Background: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for the need of anesthesia. Duration of the procedure was calculated in each case and post-operative pain was assessed by Visual analogue scale at day 1 and day 7. Results: Statistically significant difference in the need of anesthesia was found. A non-significant difference in the duration of the operation was found between the two methods. Non-significant difference was found between the two methods regarding post-operative pain at day 1, with the day 7 scores "no pain or zero pain score" in all the cases by the two methods. A directional significant correlation was found between depth of the gingival tissue over the implants and duration of the procedures regardless of the method used. Conclusion: diode laser can be used effectively for uncovering implants, providing both the dentist and the patient with additional advantages over the conventional methods. Although there was insignificant difference in pain scoring, however implant exposure by laser was more preferred by the patients.
4-amino-3-(4-(((4-hydroxy-3, 5dimethoxybenzyl) oxy) methyl) phenyl)-1, 2, 4-triazole-5-thione was synthesized by to method the first one from melt reaction of 4-(((4-hydroxy-3, 5-dimethoxybenzyl) oxy) methyl) benzoic acid with Thiocarbonyldihydrazide, the second method from convert the corresponded acid hydrazide to potassium 2-(4-(((4-hydroxy-3, 5-dimethoxybenzyl) oxy) methyl) benzoyl) hydrazinecarbodithioate salt then react with hydrazine hydrate. Newly Schiff base (7a-7f) were synthesized from reaction the 4-amino-1, 2, 4-triazol with substituted hydroxybenzaldehyde. The resulting compounds were characterized by IR, 1H-NMR, 13C-NMR, and HRMS data. 2, 2-Diphenyl-1-picrylhydrazide (DPPH) and ferric reducing antioxidant power (FRAP) assays
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri
... Show MoreBackground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm dept
... Show MorePurpose – determine the impact of the promotional mix in achieving competitive advantage in industrial organizations.
Problem- indicated a clear deficiency in employing the dimensions of the marketing mix in ensuring a competitive advantage for the researched organization.
Design/methodology/approach – Al-Dora Refinery was selected as a field of application. The sample was chosen by an intentional sample of (143) individuals in the Human Resources departments. The questionnaire was adopted as a data acquisition tool that was prepared based on a set of ready-made standards after being subjected to a number of v
... Show MoreThe adult worms of the Microphallidae family are mainly found as intestinal parasites of birds and mammals, while metacercariae is most commonly found in decapodal crustaceans. The Microphallidaeare family is spread throughout the world. It includes approximately 47 genera. Mature worms usually enter the digestive system of vertebrates, especially birds and mammals. Microphallidae contain eight subfamilies: Androcotylinae - Basantisiinae - Endocotylinae - Gynaecotylinae - Levinseniellinae - MaritrematinaeMicrophallinae - Sphairiotrematinae. Therefore, due to the lack of studies on the Microphallidae family in Iraq, we began to develop a database on this important family.
Purpose: To validate a UV-visible spectrophotometric technique for evaluating niclosamide (NIC) concentration in different media across various values of pH. Methods: NIC was investigated using a UV-visible spectrophotometer in acidic buffer solution (ABS) of pH 1.2, deionized water (DW), and phosphate buffer solution (PBS), pH 7.4. The characterization of NIC was done with differential scanning calorimeter (DSC), powder X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The UV analysis was validated for accuracy, precision, linearity, and robustness. Results: The DSC spectra showed a single endothermic peak at 228.43 °C (corresponding to the melting point of NIC), while XRD and FTIR analysis confirmed the identit
... Show More