Background: Restoration of the gingival margin of Class II cavities with composite resin continues to be problematic, especially where no enamel exists for bonding to the gingival margin. The aim of study is to evaluate the marginal leakage at enamel and cementum margin of class II MOD cavities using amalgam restoration and modern composite restorations Filtek™ P90, Filtek™ Z250 XT (Nano Hybrid Universal Restorative) and SDR bulk fill with different restoratives techniques. Materials and method: Eighty sound maxillary first premolar teeth were collected and divided into two main groups, enamel group and cementum group (40 teeth) for each group. The enamel group was prepared with standardized Class II MOD cavity with gingival margin (1 mm above C.E.J) on both box sides. While the cementum group with the gingival margin (1 mm below C.E.J) on both sides. The enamel and cementum groups were then subdivided into eight subgroups for each (five teeth) with 10 boxes for each group. Subgroups within the main group named according to materials and techniques that were used with it as following: Amalgam subgroup (Permite, SDI), SDR subgroup (DENTSPLY) with bulk technique, Filtek™ P90 subgroup (3M ESPE) with three incremental techniques (Oblique, Horizontal and Centripetal technique), and Filtek™ Z250XT subgroup (3M ESPE) with three incremental techniques (Oblique, Horizontal and Centripetal technique).After specimens were stored in distilled water at 37°C for 7 days. All specimens were subjected to thermocycling at (5° to 55 °C). Microleakage was evaluated by stereomicroscope (20 X). Data were analyzed statistically by Kruskal-Wallis test and Mann-Whitney U-test. Result: All experimental groups showed leakage at cementum more than enamel groups. SDR bulk fill subgroup showed the highest marginal leakage among all experimental groups followed by Filtek™ Z250 XT subgroup with horizontal technique at both enamel and cementum groups. Silorane and Filtek™ Z250 XT subgroups with oblique technique showed the least marginal leakage followed by centripetal technique at both enamel and cementum groups. Amalgam restoration subgroup shows lesser leakage than SDR bulk fills subgroup significantly at both enamel and cementum groups. While it show higher leakage than Silorane subgroup with oblique technique significantly at enamel margin only. Conclusion: The limiting factors for marginal leakage are technique and material dependent.
Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreBackground: Dental caries is one of the most significant problems in world health care. Restoring carious primary teeth is one of the major treatment goals for Children, and the light activated resin restoration materials like composite, resin-modified glass ionomer and polyacid-modified which was introduced in dentistry in 1970, widely used in clinical dentistry but its application increased dramatically in recent years because of its biocompatibility, color matching, good adhesive properties of its resemblance in physical and mechanical aspects to tooth. The aim of this study: To evaluate the microleakage of Polyacid-Modified Composite resin Compared to Flowable Hybrid Composite and Resin-Modified Glass ionomer cement. Materials and me
... Show MoreBackground: This study was conducted to assess the effects of various beverages on the shear bond strength of light-cured orthodontic composite used to bond stainless steel orthodontic brackets on human teeth and to determine the site of bonding failure of this material. Materials and Methods: Fifty extracted human premolars were selected and randomly divided into five equal groups each with 10 teeth according to the beverage type (Control, One Tiger, Milk, Green tea and Coffee). After bonding, the teeth were immersed in specific beverages for 5 minutes twice daily with equal intervening intervals then washed and stored in distilled water at 37º C for the reminder of the day. The process was carried out for 30 days. The samples were then
... Show MoreIn this research design was treated gap laser mathematically and practically Bashaddam model Raasi simple and new and we have found that there is a good match in the practical and theoretical results
To evaluate the Interaction of Mn(II), Fe(II), Co(II), Ni(II),Cu(II), Zn(II) And Cd(II) Mixed- Ligand Complexes of cephalexin mono hydrate (antibiotics) And Furan-2-Carboxylic Acid To The Different DNA Sources. All the metal complexes were observed to cleave the DNA. A difference in the bands of complexes .The cleavage efficiency of the complexes compared with that of the control is due to their efficient DNA-binding ability and the other factors like solubility and bond length between the metal and ligand may also increase the DNA-binding ability. The ligands (Cephalexin mono hydrate (antibiotics) and Furan-2- Carboxylic acid and there newly synthesized metal complexes shows good antimicrobial activities and Binding DNA , thus, can be used
... Show MoreIn the name of Allah, the Beneficent, the Merciful.
Praise be to Allah, Lord of the Worlds and peace and blessings on the honest and trustworthy (Muhammad) and his family and his divine good companions.
The Islamic clothing is one of the requirements of the common and original innateness to humans; the innateness that is created by God to all people, Allah says, (So set thou thy face steadily and truly to the Faith: [establish] Allah's handiwork according to the pattern on which He has made mankind: no change [let there be] in the work [wrought] by Allah: that is the standard Religion: but most among mankind understand not) (1). Islam as a natural religion has ordered the Muslims to wear decently, Allah says, ( O Children of Adam!
Effects of Ozonated Water on Micro Leakage between Enamel and Fissure Sealants Prepared by Different Etching Technique (An in vitro Study), Baraa M Jabar*, Muna S Khalaf
ABSTRACT Background: This study aimed to study the effect of some acidic drinks (Vinegars and fresh Orange juice) and energy drinks (Red bull) on surface roughness of three types of bulkfill composite materials: Filtek posterior bulkfill (3M), Sonicfill (Kerr) and Filtek p60 (3M). Materials and Methods: Total number of 120 samples are prepared by using a mold of (12mm diameter and 3mm height), which were divided into three groups forty samples for each group: Group A: Filtek bulkfill posterior composite (3M), Group B: Sonicfill composite (Kerr), Group C: Filtek P60 (3 M) which then divided into four sub- groups (n=10) (1) samples were kept in distilled water as a control group (2) samples were immersed in Redbull (3) samples were immersed
... Show MoreA new Schiff base ligand Bis-1,4-di[N-3-(2-hydroxy-1-amino)- acetophenonylidene] benzylidene [L] and its complexes with (Mn(II) ,Co(II) ,Ni(II and Cu(II)) were synthesized . The ligand was prepared in two steps. In the first step a solution of (terphthalaldehyde) in methanol reacts under reflux with (p-aminoacetophenone) to give an intermediate compound [1-[3-({4-[(3-Acetyl-phenylimino)-methyl]-benzylidene}-amino)-phenyl]- ethanone which reacts in the second step with (2-Amino-phenol) giving the mentioned ligand. The complexes were synthesized by addition the corresponding metal salt solution to the solution of the ligand in methanol under reflux in (1:1) metal to ligand ratio. On the basis of, molar conductance, I.R., UV-Vis, HPLC, chlorid
... Show More