Preferred Language
Articles
/
jbcd-253
Comparison of regional bond strength of post space of fiber-reinforced post luted with two types of cements at different testing times
...Show More Authors

Back ground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), Time and the mode of polymerization (dual, self-cured) of the cements used on the bond strength between translucent fiber post and root dentin by using push-out test. Materials and Methods: Forty eight extracted mandibular first premolars (single root) were instrumented with ProTaper Universal system files (for hand use) and obturated with gutta percha for ProTaper and AH26® root canal sealer following the manufacturer instructions, after 24 hours post space was prepared using FRC postec® plus drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into two main groups (24 samples each) according to the used cement (Group M, self-cure, Multilink N) and (Group R, dual cure, Relyx U100). Then each group was subdivided into three groups (each group contains 8 samples) according to the testing time after cementation. (g M1: push out test after 24 hour of cementation with Multilink N), (g M2: push out test after one week of cementation with Multilink N),(g M3: push out test after two weeks of cementation with Multilink N), (g R1: push out test after 24 hours of cementation with RelyxU100), (g R2: push-out test after one week of cementation with RelyxU100), (g R3: push out test after two weeks of cementation with RelyxU100). After cementation and incubation each root was sectioned horizontally into 3 slices (2 mm in thickness) represent the coronal, middle and apical regions of the post space. Push out bond strength test was performed and measured using a universal testing machine (Tinius-Olsen) at across head speed of 0.5 mm/min. Results: showed that regarding the root region, the bond strength values increased significantly apical to coronal region in both tested cements. For the effect of time, the bond strength values also significantly increased with time for both tested cements. For mode of polymerization, the self-cured resin cement Multilink N showed higher bond strength values. Conclusion: the retention of fiber post was affected by root region, mode of polymerization of the cements used and time elapsed after cementation of the post.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Investigation of Doppler broadening Compton scattering for aluminum element at different angles
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Tue Nov 27 2018
Journal Name
Bioscience Research
Silver nanoparticles biosynthesis and their antimicrobial activity against wild and mutant isolates of different G-ve bacterial types
...Show More Authors

Five isolates of Gram negative bacteria (Klebsiella pneumoniae, Psuedomonas auroginosa, proteus mirabilis and two strains of E.coli) were in quested for the ability of bearing silver nanoparticles by using LB medium, all the isolates of bacteria were buttered brown color just as soon as mixed the supernatant of bacterial culture with AgNO3 solution, that refered the biosynthesis of Silver nanoparticles (Ag NPs). UV–visible spectrophotometer and Fourier transform infrared (FTIR) spectroscopy were utilized for estimation of (Ag NPs). The five isolates of bacteria were tendered to produce spontaneous mutants by using different kinds of antibiotics, Ampicillin put to use for making mutant in E.coli and Proteus mirabillis, while Pseudom

... Show More
Scopus (3)
Scopus
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Estimation of cellular immune response by evaluation of some cytokines in immunopathogenesis of chronic hepatitis B and C pre- and post- treated Iraqi patients (in vivo and in vitro)
...Show More Authors

Two groups of chronic hepatitis B and C virus patients were divided into Pre-treated patients (25 CHB patients with positive HBs Ag for more than 6 months and 40 CHC patients), and post-treated patients [12 CHB patients (4, 6, and 2 were treated with lamivudine, IFN-? and combination of LMV + IFN-? respectively), and 27 patients for CHC (3, 13 and 11 patients were treated with Ribavirin, IFN-? and combination therapy (RBV+ IFN-?) respectively].These patients were followed up for 6 months. By using ELISA technique, levels of IL-6, IL-10, IFN-? and TNF-? were measured in vivo and in vitro (supernatant of PBMCs stimulated with PHA) and compared with healthy control. The mean level of IL-6, IL-10 and TNF-? in CHB patients showed significant dif

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Ions release from fixed orthodontic appliance in two different mouthwashes
...Show More Authors

Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Bioequivalence and Pharmacokinetics Comparison of Two Formulations of Extended-Release Pentoxifylline Tablets in Healthy Subjects after Fasting and Fed Conditions
...Show More Authors

The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples we

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Response of Damaged Reinforced Concrete Beams Strengthened with NSM CFRP Strips
...Show More Authors

This paper presents a study (experimentally) for strengthening reinforced concrete (RC) beams with Near-Surface-Mounted (NSM) technique. The use of this technique with CFRP strips or rebars is an efficient technology for increasing the strength for flexure and shear or for repairing damaged reinforced concrete (RC) members. The objective of this research is to study, experimentally, RC beams either repaired or strengthened with NSM CFRP strips and follow their flexural behavior and failure modes. NSM-CFRP strips were used to strengthen three RC beam specimens, one of them was initially strengthened and tested up to failure. Four beam specimens have been initially subjected to preloading to 50% and 80% of ultimate load. Two of the sp

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Wear rate of epoxy resin reinforced with multi walls carbon nanotubes
...Show More Authors

In this study, nanocomposites have been prepared by adding
multiwall carbon nanotubes (MWCNTs) with weight ratios (0, 2, 3,
4, 5) wt% to epoxy resin. The samples were prepared by hand lay-up
method. Influence of an applied load before and after immersion in
sodium hydroxide (NaOH) of normality (0.3N) for (15 days) at
laboratory temperature on wear rate of Ep/MWCNTs
nanocomposites was studied. The results showed that wear rate
increases with increasing the applied load for the as prepared and
immersed samples and after immersion. It was also found that epoxy
resin reinforced with MWCNTs has wear rate less than neat epoxy.
The sample (Ep + 5wt% of MWCNTs) has lower wear rate. The
immersion effect in base so

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Analysis of concrete beams reinforced by GFRP bars with varying parameters
...Show More Authors
Abstract<p>Structural buildings consist of concrete and steel, and these buildings have confronted many challenges from various aggressive environments against the materials manufactured from them. It contains high water levels and buildings whose concrete cover may be damaged and thus lead to the deterioration and corrosion of steel. It was important to have an alternative to steel, such as the glass fiber reinforced polymer (GFRP), which is distinguished by its great effectiveness in resisting corrosion, as well as its strong tensile resistance. Still, one of its drawbacks is that it has a low modulus of elasticity. This research article aims to conduct a numerical study using the nonlinear fi</p> ... Show More
Scopus (16)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Behaviour of Fire Exposed Reinforced Concrete Rigid Beams with Restrained Ends
...Show More Authors

This paper is devoted to investigate the effect of burning by fire flame on the behavior and load carrying capacity of rectangular reinforced concrete rigid beams. Reduced scale beam models (which are believed to resemble as much as possible field conditions) were suggested. Five end restrained beam specimens were cast and tested. The specimens were subjected to fire flame temperatures ranging from (25-750) ºC at age of 60 days, two temperature levels of 400ºC and 750ºC were chosen with exposure duration of 1.5 hour. The cast rectangular reinforced concretebeam (2250×375×375 mm) (length× width× height respectively) were subjected to fire. Results indicate remarkable reduction in the ultrasonic pulse velocity and rebound number of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Fusion Splicing for a Large Mode Area Photonic Crystal Fiber with Conventional Single Mode Fiber
...Show More Authors

In this paper the experimentally obtained conditions for the fusion splicing with photonic crystal fibers (PCF) having large mode areas were reported. The physical mechanism of the splice loss and the microhole collapse property of photonic crystal fiber (PCF) were studied. By controlling the arc-power and the arc-time of a conventional electric arc fusion splicer (FSM-60S), the minimum loss of splicing for fusion two conventional single mode fibers (SMF-28) was (0.00dB), which has similar mode field diameter. For splicing PCF (LMA-10) with a conventional single mode fiber (SMF-28), the loss was increased due to the mode field mismatch.

View Publication Preview PDF