Background: with the advent of new postmaterial in dentistry, it has become important to measure fitness of post restoration along the horizontal plane of the root space.This study aimed to measure and compare, the cement film thickness of conventional zinc phosphate cement in micrometer between the post and root dentin along horizontal plane at different post space regions (coronal, middle and apical) of four types of posts, by using stereomicroscopy. Material and methods: Thirty-two extracted human maxillary canines, mandibular canines and maxillary central incisors (n=32) were instrumented with ProTaper system files (hand use) and obturated with gutta-percha for ProTaper and AH26® root canal sealer. After 24hrs of incubation at 37ºC, post space was prepared using FRC Postec® plus drills no.3 and ER Cera reamer size 70, creating 10 mm deep post space. The prepared samples were then randomly divided into four main groups (8 samples each) according to the type of post used (Group A: fabricated cast metal post), (Group B: fabricated zirconia post), (Group C: prefabricated glass fiber reinforced composite post), (Group D: prefabricated zirconia post). After cementation and incubation period of 24hrs, each root was sectioned horizontally into 3 discs (2mm in thickness) at the coronal, middle and apical regions of the root space. The cement thickness between post and root dentine was measured (in µm) by using a stereomicroscope. Results: The results of this study showed that the lowest mean of cement thickness was in group C (35.28?m), followed by group A (78.12?m) and group D (81.9?m), and all three groups demonstrated acceptable cement thickness, while group B produced unacceptable cement thickness (127.34?m). One way ANOVA test revealed a statistically highly significant difference for the cement thickness among four post types used within each region of the root. Conclusions: the root region and type of post system have an effect on cement thickness along post space.
Abstract:
The aim of the present research is to evaluate the child’s nutritional
method (2-5 years old) which is based on his resistance of the food highly rich
with nutritional elements and his acceptance of the food of a low nutritional
value in addition to his having forbidden food with other mates and making
use of all mates when having food, in establishing the sound social values and
affection since child hood. The required statistical equation have been used
by the researcher namely (Z test).
The sample of the present study consists of (26) children who were selected
intentionally and randomly from the kindergartens of Al-Bayaa region and the
college of Education for women. The questionnaires were d
To study the site of placentae and the umbilical artery blood flow of different age groupsand relate that to the newborn baby and the mother. 117 placentae samples were investigatedusing ultrasound and 30 placentae samples were studied using Doppler ultrasound during theperiod from August 2007 to August 2008 for full term placentae of mothers aged 15- > 45 yearsold. By ultrasound; there was detection of good pe rcentage of the placental site to be on theposterior wall of the uterus in case of male babies, while it was anterior in case of female babiesand it was previa and fundal in females more than in the males. The Doppler ultrasound revealedthat the mother in any age group can conceive and have a healthy placenta because the readings ina
... Show MoreBackground: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for th
... Show MoreThis paper presents theoretical parametric study of the curvature ductility capacity for reinforced concrete column sections. The study considers the behavior of concrete and reinforcing steel under different strain rates. A computer program has been written to compute the curvature ductility taking into account the spalling in concrete cover. Strain rate sensitive constitutive models of steel and concrete were used for predicting the moment-curvature relationship of reinforced concrete columns at different rate of straining. The study parameters are the yield strength of main reinforcement, yield strength of transverse reinforcement, compressive strength of concrete, spacing of ties and the axial load. The results indicated that hi
... Show MoreThe adult worms of the Microphallidae family are mainly found as intestinal parasites of birds and mammals, while metacercariae is most commonly found in decapodal crustaceans. The Microphallidaeare family is spread throughout the world. It includes approximately 47 genera. Mature worms usually enter the digestive system of vertebrates, especially birds and mammals. Microphallidae contain eight subfamilies: Androcotylinae - Basantisiinae - Endocotylinae - Gynaecotylinae - Levinseniellinae - MaritrematinaeMicrophallinae - Sphairiotrematinae. Therefore, due to the lack of studies on the Microphallidae family in Iraq, we began to develop a database on this important family.
Background: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. The aim of the present in vitro study was to evaluate and compare the static frictional forces produced by two passive self-ligating brackets stainless-steel and hybrid and two conventional brackets stainless-steel and monocrystal ligated with stainless-steel ligature wire at two degrees of torque(zero and twenty) under dry condition. Materials and method: One hundred and sixty brackets were used in this study divided into four groups each group consisted of forty brackets these are: Two self-li
... Show MoreA total of 41 patients with gastro duodenal symptoms (show signs of inflammation with or without duodenal ulcer) . 21 males (51.2%) and 20 female (48.8%) with an average age 0f (20 – 80) years old under going gastrointestinal endoscopy at Baghdad teaching hospital in internal disease clinical laboratory , between (February – June) 2009 . Biopsies specimen of antrum , gastric fundus ,& duodenal bulb were examined by the following methods (rapid urease test , Giemsa stain section to detect bacteria , & Haematoxilin and Eosin stained section for pathological study which are considered the gold standard methods , sera or plasma from these patients were tested by immunochromotography (ICM),serological m
... Show MoreIn this study, 191 specimens of insects that infect species of the Fabaceae family, including: