Background: The symptoms of Parkinson's disease (PD) can lead to problems in movement and coordination that lead to difficulty in maintaining well oral cleaning which can then negatively affect dental status of those Patients. The aim of present study: To evaluate prosthetic status in relation to weight status and occupation by age and gender among Parkinson's disease Patients in Baghdad-Iraq. Methods: The sample consisted of 104 patients with Parkinson disease attended to the Neurosciences Hospital in Baghdad city / Iraq, aged 60-79 years Prosthetic Status was recorded according to WHO(1997). Weight status was recorded according to Trowbridge 1988 and occupation was recorded according to Erikson and Goldthorpe (1992) and Ganzeboom et al (1989). Results: The subjects without prosthesis tend to be more from any prosthesis type followed by partial denture and bridge, all types of prosthesis found to be decreased with increasing of age in both arches except combination of bridge and partial denture and complete denture were found to be increased with increasing of age with statistically highly significant association between age and prosthesis in upper arch. Males were found to have more prosthesis than females but with statistically no significant association. The subjects without any prosthesis, both bridge and partial denture types in upper arch found more in normal weight than the over and obese ones, while the combination of bridge and partial denture with complete denture tend to have slightly more in over weight with highly significant association. In lower arch other two prosthesis categories tend to be more in overweight subjects than other their counterparts with equally distributed of partial denture between normal and obese ones whose this prosthesis tend to be more than the overweight ones with statistically significant association. The with+ without+ self-employees category tends to have no prosthesis, partial denture and bridge prostheses more than other their counterparts with approximately equally distributed of other prosthesis categories but with statistically no significant association in upper arch while in lower arch the percentage of subjects with free prosthesis was found in with+ without+ self-employees category, while the partial denture and bridge found to be more in with+ without+ self-employees and upper grade professional but these findings tend to be statistically no significant association. Conclusion: Age, gender, occupation and weight have an effect on prevalent of prosthetic status of Parkinson’s disease patients. This may be due to difference in previous oral hygiene, health awareness, severity of Parkinson’s disease and difference in income status between them.
The study involved preparing a new compound by combining between 2- hydroxybenzaldehyde and (Z)-3-hydrazineylideneindolin-2-one resulting in Schiff bases and metal ions: Mn(II), Co(II), Ni(II), Cu(II), and Zn(II) forming stable minerals-based-Schiff complexes. The formation of resulting Schiff bases is detected spectrally using LC-Mss which gave corresponding results with theoretical results, 1H-NMR proves the founding of N=CH signal, FT-IR indicates the occurrence of imine band and UV-VIs mean is proved the ligand formation. On the other hand, minerals-based-Schiff was characterized using the same spectral means that relied with ligand (Schiff bases). Those means gave satisfactory results and proved the suggested distinguishable geometries
... Show MoreAbstract Rasha Hameid Jehad Baghdad University Background: The high reactivity of hydrogen peroxide used in bleaching agents have raised important questions on their potential adverse effects on physical properties of restorative materials. The purpose of this in vitro study was to evaluate the effect of in-office bleaching agents on the microhardness of a new Silorane-based restorative material in comparison to methacrylate-based restorative material. Materials and method: Forty specimens of Filtek™ P90 (3M ESPE,USA) and Filtek™ Supreme XT (3M ESPE, USA) of (8mm diameter and 3m height) were prepared. All specimens were polished with Sof-Lex disks (3M ESPE, USA). All samples were rinsed and stored in incubator 37˚C for 24 ho
... Show MoreHouse 21 fungal isolates fungus to the analyst Albroca output of manufactured blood clot from the Blama human blood showed positive fungi to test analyzes blood clot variation in times where decomposition recorded fungi
Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri
... Show MoreAbstract
The study aims to clarify the impact of the adoption of the International Financial Reporting Standard (IFRS16) on lease contracts in the General Iraqi Insurance Company on the financial statements, and thus the impact on financial ratios and indicators, Since the financial reporting standard considers lease contracts as an asset called the right to use the asset and is offset by a liability, this changes the way the financial statements are presented, with an addition to both the asset and liability sides. In order to show the extent to which the adoption of the standard reflects on the financial performance
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri
... Show MoreThis research aims to identify the relationship between occupational hypocrisy and organizational strategic success, It was done by analyzing the correlations and influence between variables, applied to a random sample of university professors at the University of Kufa faculty of administration and economic.
The main tool for data collection is the survey were questionnaires were distributed randomly to the professors , and (43) questionnaires were returned, and test its validity by using (SEM) (Structural Equation Modeling), Hypothesis has been tested by using Statistical Package for Social Sciences (SPSS v. 18), The research found a set of conclusions:(The occupational hypocrisy has
... Show MoreBackground: Polymethylmethacrylate (PMMA) has relatively unsatisfactory mechanical properties such as low flexural strength and impact strength also dimensional instability. Material and method: Zirconium silicate nanoparticles were coated with a layer of trimethoxysilylpropylmethacrylate (TMSPM) before sonication in monomer (MMA) with the percentages 1% and 1.5% by weight then mixed with powder using conventional procedure, (150) samples were prepared and divided into three groups, each group consisted of (50) samples, the first group prepared from PMMA without addition (control), another group with the addition of 1% wt Zrsio4 nanoparticles (experimental) and the third one with 1.5% wt Zrsio4 nanoparticles (experimental). Each group
... Show More