Back ground: Microbial penetration inside the implant's internal hole creates a bacterial reservoir that is related with an area of inflamed connective tissue opposite the fixture-abutment junction and this can affect the health of the peri-implant tissue. Aims of the study: Evaluate the types aerobic and anaerobic bacterial count-percentage and difference between Aerobic and Anaerobic microflora in the implant screw hole three months after implant placement. Monitor the periodontal health status of all patients, throughout the study. Material and methods: Study methodology; Eight partially edentulous patients received 20 dental implants and these implants done with flapless surgical procedure. All patients examined clinically to determined their oral health status by examination of their plaque index, Gingival index and Bleeding on probing, each two weeks for 90 days (8visits) throughout the study period. Three months after that, the plaque sample collected from the internal hole of fixture and transfer to bacterial investigation and assessment the amount of anaerobic and aerobic bacteria. Results: Although the anaerobic viable count is higher than that of aerobic, but with statistically not significant difference between those counts (P>0.05). Keywords: screw hole, flapless surgical implant placement, bacterial count, Aerobic and Anaerobic bacteria
Objectives: The study aims at:
1- Measuring the level of lead in workers’ saliva and blood in the factory.
2- Studying the correlation between the saliva lead level and the infection that caused by microorganisms, isolation and
identification.
3-Studying the influence of high blood lead level on the total white blood cells.
Methodology: This study has been conducted for the period from March 15th, 2010 to May, 20th
, 2010. A total of (60)
saliva and blood samples were collected from workers in batteries industry factory in Baghdad and another (20) samples
were collected as a control group. Lead level had been measured in blood and saliva samples, then microorganisms were
isolated the from the saliva samples.
The main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a
... Show MoreTo evaluate the toxicity of benzalkonium chloride in aquaculture, the hemato-serological indices of Nile tilapia Oreochromis niloticus are used as biomarkers. Following exposure to three concentrations of benzalkonium chloride BAC 0.1, 0.25, 0.50, and 1 mg/l (BAC1,2,3 and 4) in aquaria for two durations 21 and 42 days, the microbiological assay in fish aquaria, in addition to blood parameters were assessed. Except for the mean difference between BAC2 and BAC3 (P > 0.05) at 42 days, the mean values of the bacterial counts revealed a significant difference between all compared groups (0.05 ≥ P ≤ 0.01). Following exposure to the lower concentrations of BAC (1, 2 and 3), the main blood parameters of Oreochromis niloticus namely red bl
... Show MoreCarpal tunnel syndrome is a neurological disease that presented with paresthesias, pain, and numbness in the hand's median nerve compression. Vitamin D was assumed to affect both electrophysiological &clinical gradings, the study aims to assess the correlation between the deficiency of vitamin D and both electrophysiological and clinical gradings. This study was conducted in Ghazi Alhariri Hospital during the period from the first of November/2020 to the twenty-eighth of February/2021, fifty five individuals were referred to as Carpal tunnel syndrome patients, and compared to (55) control individuals, blood samples were withdrawn from the patients (3ml), centrifuged and kept in the freezer (-20°C) until the time of analysis of
... Show MoreOBJECTIVE: Synthetic vertebral body replacement has been widely used recently to treat different spinal conditions affecting the anterior column. They arrange from trauma, infections, and even tumor conditions. In this study, we assess the functional outcome of this modality in different spinal conditions. PATIENTS AND METHODS: Thirty-six cases operated from October 2010 to December 2017. Twelve patients had spinal type A3 fractures, 11 cases with spinal tuberculosis (TB), and 13 cases with spinal tumors. They were followed clinically for a mean period of 2.4 years. RESULTS: All the cases were approached anteriorly. Seven cases had a post-operative infection. No neurological worsening reported. We had dramatic neurologic
... Show MoreTo investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.
Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflec
Based on the streamer growth model, the streamer discharge propagation was simulated in aid of finite element technique. That was done within two non- mixed dielectric liquids (Normal-Hexane and Acetone) located between two electrodes in pin - plane configuration. The output results show that, the path of the streamer was affected by the interface between the two liquids; the streamer path crosses this interface under some conditions such as the permittivity of the liquids and the distance between this interface and the tip of the pin. Under other conditions, the streamer path grows along the interface. The results were assisted by the development of the potential and the electric field distributions with the growth of the streamer propa
... Show MoreThe Tigris River is a major source of Iraq’s drinking and agricultural water supply. An increase in pollution by heavy metals can be a great threat to human and aquatic life. In this study, the pollution index (PI) and metal index (MI) were used to evaluate the status of the Tigris River in Baghdad City. Five stations were chosen to conduct the study. Five heavy metals were analyzed: iron (Fe), lead (Pb), nickel (Ni), zinc (Zn), and chromium (Cr). The result of PI was ranked between “No effect to moderately affected for Fe; Slightly Affected to Seriously Affected for Pb; no effect to moderately affected for Ni, and no effect to strongly affected for Cr; only Zn was in the No effec
The main source of water supply in Iraq is the surface water, especially Tigris and Euphrates Rivers and their tributaries. In the recent years there was a great drop in the water levels of Tigris River within Baghdad City which had affected the operation of twelve water supply projects located on the banks of Tigris River in Baghdad City, due to significant climate changes, and the expansion of hydraulic construction (dams) and implementation of new irrigation projects in Turkey, these factors have greatly reduced the water flowrates of river by about 46%. In the present study the flow characteristics of Tigris River within Baghdad City was studied, the reach involved was about 49km in which it represents the urban zone
... Show More