Preferred Language
Articles
/
jbcd-2461
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample include (60) Iraqi subjects (30 male and 30 females) aged between 20-65 years, sagittal view of Cone beam computed tomography was obtained to measure the height ,width and alveolar bone density of the mandibular anterior area, while coronal view was used to measure the height ,width and alveolar bone density assessment of the mandibular premolar and molar areas. Measurement of mandibular bony height and width was in(mm)and each of the three mandibular areas were represented by seven consecutive measurements for bony height and width and these seven stations were set using an average distance of 2 mm apart while the bone density in Hounsfield unit (HU) with point of measurement represent the mean of density to the area located between the height and buccolingual width. Results:The Statistical analysis of linear measurements of mandibular bone which include the bony height , width and density showed that the mean values of all three measurements are significantly higher in males than females also there was statistically significant difference in the mean bone density of mandibular areas which was highest in anterior area and lowest in the molar area followed by premolar area among both gender, mandibular bony height showed a statistically insignificant very weak negative linear correlation with age in all the three examined mandibular areas while the effect of age on bucolingual width was significantly higher among subjects older than 50 years compared to those younger than 50 years old. Conclusion: The mean bony height was highest in anterior area and lowest in premolar area followed by molar area, while the mean bony width was lowest in anterior area and highest in molar area followed by premolar area , finally the mean bone density was highest in anterior area and lowest in molar area followed by premolar area.

Crossref
View Publication
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Association between Allelic Variations of -174G/C Polymorphism of Interleukin-6 Gene and Chronic Kidney Disease-Mineral and Bone Disorder in Iraqi Patients
...Show More Authors

This study designed to examine association between-174G/C polymorphism of interleukin-6 gene and phosphate, calcium, vitamin D3, and parathyroid hormone levels in Iraqi patient with chronic kidney disease on maintenance hemodialysis. Seventy chronic renal failure patients (patients group) and 20 healthy subjects (control group) were genotyped for interleukin-6 polymorphism and genotyping was performed by conventional polymerase chain reaction-restriction fragment length polymorphism. No significant differences in phosphate levels were observed in patients and control with different interleukin-6 genotypes. Control had non-significant differences in calcium levels, while patients with GG and CG genotypes displayed significant e

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Feb 27 2021
Journal Name
Journal Of Engineering
Assessment of Electromagnetic Pollution in Some Hospitals and Schools in Al-Najaf City
...Show More Authors

The tremendous benefits of using cellular phones, which began to increase and unprecedented spread worldwide last decade, were accompanied by harmful effects on the environment due to the increase in electromagnetic radiation (EMR) which be emitted from mobile phone towers. This effect on humans, animals, and plants, which is considered a form of environmental pollution, was sensed by developed countries and Environmental protection organizations. These countries have established restrictions and enacted laws to reduce their negative impact on living beings. The field survey included six major hospitals and 38 schools were distributed over the central neighbourhoods in Al-Najaf city. The results showed that power density (PD) measurement

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Influence of water-absorbent polymer balls on the structural performance of reinforced concrete beam: An experimental investigation
...Show More Authors
Abstract<p>This research investigated the influence of water-absorbent polymer balls (WAPB) on reinforced concrete beams’ structural behavior experimentally. Four self-compacted reinforced concrete beams of identical geometric layouts 150 mm × 200 mm × 1,500 mm, reinforcement details, and compressive strength <inline-formula> <alternatives> <inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/j_jmbm-2022-0024_eq_001.png"></inline-graphic> <math xmlns:m="http://www.w3.org/1998/Math/MathML"> <msubsup> <mrow> </mrow></msubsup></math></alternatives></inline-formula></p> ... Show More
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Advances In Cancer Biology - Metastasis
CX3CL1 as potential immunotherapeutic tool for bone metastases in lung cancer: A preclinical study
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Assessment of Solar Photovoltaic Potential in Iraq
...Show More Authors

View Publication
Scopus (13)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
The Effect of Assessment Techniques on EFL Learners’ achievement in TOEFL Test
...Show More Authors

While many educators are highly focused on state test, it is important to consider that
over the course of a year, instructors can build in many opportunities to assess how learners
are learning. Therefore, assessment techniques are considered a good method to get benefit
for both instructors and learners in the process of teaching and learning. The sample consists
of 27 learners who participated in TOEFL training course in the Development and Continuous
Education Centre. Validity and reliability were verified.
To fulfill the aims and verify the hypothesis which reads as follows” It is hypothesized
that the TOEFL learners' scores will not be increased after TOEFL course training.” T-test
for two dependent samp

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2019
Journal Name
Annals Of Medicine And Surgery
Assessment of the difficulties in laparoscopic cholecystectomy among patients at Baghdad province
...Show More Authors

Scopus (7)
Scopus
Publication Date
Mon Mar 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between the mesiodistal crown dimensions of second primary molar with stainless steel crowns from different companies
...Show More Authors

Background: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated usin

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Mon Apr 03 2023
Journal Name
Journal Of Educational And Psychological Researches
Fitting Scoring Rubrics for Electronic Portfolio to Partial Credit Model According to the Number of Assumed Dimensions
...Show More Authors

Abstract

 

The current research aims to reveal the extent to which all scoring rubrics data for the electronic work file conform to the partial estimation model according to the number of assumed dimensions. The study sample consisted of (356) female students. The study concluded that the list with the one-dimensional assumption is more appropriate than the multi-dimensional assumption, The current research recommends preparing unified correction rules for the different methods of performance evaluation in the basic courses. It also suggests the importance of conducting studies aimed at examining the appropriateness of different evaluation methods for models of response theory to the

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref