Preferred Language
Articles
/
jbcd-2444
Waterpipe Smoking Effect on Clinical Periodontal Parameters, Salivary Flow Rate and Salivary pH in Chronic ‎Periodontitis Patient
...Show More Authors

Background: Waterpipe tobacco smoking has become common especially among young people, Waterpipe smoking misconcepted as a safer mean of smoking, so in this study we will highlight the effect of Waterpipe smoking ‎on periodontal and oral health.‎ Materials and method. The selected ‎‎‎100 male subjects of 30-40 years, ‎categorized into 4 groups (each group ‎‎25 subject): Waterpipe smoker ‎with ‎healthy periodontium, ‎Waterpipe smoker ‎‎with chronic periodontitis, Non-‎‎smoker ‎with healthy periodontium and Non-smoker ‎with chronic periodontitis. Whole ‎unstimulated ‎saliva was collected. Clinical measurements: plaque ‎index, ‎gingival index, ‎bleeding on probing, salivary flow ‎rate ‎and ‎salivary pH were recorded‎.‎ ‎ Results. In the healthy groups: plaque index and salivary pH were ‎higher in smokers than non-smokers but with no ‎significant difference (P>0.05). While gingival index and salivary flow rate were ‎higher in smoker than non-smokers and with significant ‎difference (p<0.05). In the chronic periodontitis groups: plaque index, gingival index and salivary flow rate ‎were higher in the non-smokers than smokers and with ‎significant difference (p<0.05). While salivary pH was ‎higher in the non-smokers than smokers but with no ‎significant difference (P>0.05). Correlation between ‎weekly smoking hours with pH and salivary flow rate, in the ‎smoker healthy groups, showed ‎significant negative correlation, while plaque index showed ‎significant positive correlation at (p<0.05). But in the smokers with chronic periodontitis, only gingival index ‎significantly correlated with weekly smoking hours. Conclusion. Waterpipe smoking has a detrimental effect on the periodontium and overall oral health.

Crossref
View Publication
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Study of the effect of some pregnancy parameters on Malon dialdehyde concentration in pregnant women
...Show More Authors

The present study aimed to evaluate the concentration of Malon dialdehyde (MDA) in pregnant women during different stages of pregnancy (stage of pregnancy, abortion, contraceptives and parity number).The study included (120) blood samples from normal pregnant women in age of the procreating were subdivided into three trimesters of pregnancy (40/group), and (40) samples from non-pregnant women as a control group. The results showed a significant increase in MDA in three stages of pregnancy compared with the control group. The concentration of MDA increased significantly in pregnant women with multipregnancy when compared with pregnant women for the first time, and in pregnant women whom was using contraceptions compared with p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Research on Flow-Induced Vibration in Valves
...Show More Authors

Abstract  

All central air conditioning systems contain piping system with various components, sizes, material, and layouts. If such systems in operating mode, the flow in piping system and its component such as valves can produce severe vibration due to some flow phenomenon’s. In this research, experimental measurements and numerical simulation are used to study the flow-induced vibration in valves. Computational fluid dynamics (CFD) concepts are included with one-way and two-way fluid-structure interaction concepts by using finite element software Package (ANSYS 14.57). Detection analysis is performed on flow characteristics under operation conditions and relations with structural vibration. Most of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Physics
Effect of pH on the Structural and Optical Properties of Cadmium oxide Thin Films Prepared Using the Successive Ionic Layer Adsorption and Reaction (SILAR) Method
...Show More Authors

Cadmium oxide (CdO) thin films were deposited using the sequencing ion layer adsorption and reaction (SILAR) method. In this study, the effect of the pH value of an aqueous solution of cadmium acetate at a concentration of 0.2 mol of the cadmium oxide film was determined. The solution source for the cadmium oxide film was cadmium ions and an aqueous ammonia solution. The CdO films were deposited on glass substrates at a temperature of 90 ℃. The cadmium oxide film thickness was determined by the weight difference method at pH values ​​(7.2, 8.2). X-ray diffraction (XRD) and scanning electron microscopy (SEM) showed that the size of the crystals increased with the increase in the solution (pH). While the UV-visible spectra of the fil

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Gingival recession and periodontal therapy
...Show More Authors

Background: Gingival recession is defined as the apical migration of the gingival margin below the cementoenamel junction (CEJ), resulting in exposure of the root surface and it is one of the main esthetic complaints of patients. The management of gingival recession and its sequelae is based on a thorough assessment of the etiological factors and the degree of tissue involvement.

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
The Effect of Electrospinning Parameters on Morphological and Mechanical Properties of PAN-based Nanofibers Membrane
...Show More Authors

The electrospun nanofibers membranes (ENMs) have gained great attention due to their superior performance. However, the low mechanical strength of ENMs, such as the rigidity and low strength, limits their applications in many aspects which need adequate strength, such as water filtration. This work investigates the impact of electrospinning parameters on the properties of ENMs fabricated from polyacrylonitrile (PAN) solved in N, N-Dimethylformamide (DMF). The studied electrospinning parameters were polymer concentration, solution flow rate, collector rotating speed, and the distance between the needle and collector. The fabricated ENMs were characterized using scanning electron microscopy (SEM) to understand the surface morphology and es

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
The effect of Tramadol on some blood and biochemical parameters of male rats (Rattus norvegicus)
...Show More Authors

The present study aimed to explain the dose-dependent possible deleterious effects of 30 day administration of Tramadol on some hematological and biochemical parameters of laboratory male rats (Rattus norvegicus), the study consisted of eighteen adult male rats randomly divided into three equal groups (each of six). Group 1 (control) were treated by intraperitoneal injection of normal saline solution (0.2 ml), group two (low dose) was treated by intraperitonealy (i.p) injection of Tramadol at a dose of 50 mg/kg/day, group three (high dose) was treated by intraperitonealy injection of Tramadol at a dose of 100 mg/kg/day for 30 days. At the end of experimental period, rats were sacrificed. Blood were collected by cardiac puncture to inv

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Effecting of pH Parameter on Simulated Wastewater Treatment Using Electrocoagulation Method
...Show More Authors

The aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of  2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (16)
Scopus Crossref
Publication Date
Tue Jan 03 2017
Journal Name
World Journal Of Experimental Biosciences
Effect of Soil Extracts on Ability of Clinical Isolates of Pseudomonas aeruginosa and Staphylococcus aureus to Produce Biofilm in vitro
...Show More Authors

In present study the effect of soil extracts of different types of soil on ability of two clinical isolates, Pseudomonas aeruginosa and Staphylococcus aureus to form biofilm. The extract of soil was done by using sterile phosphate buffer saline and analyzed by Fourier Transform Infrared Spectroscopic (FTIR). Spectrophotometric method was used to check ability of the studied isolated bacteria to form biofilm on polystyrene microtiter plates. The data of FTIR showed very little difference was observed among extracts of three types of soil (soil contaminated with hydrocarbons; garden soil collected from gardens of al-jadrea, Baghdad and containers soil), but the highest difference was observed in the extract obtained from peat moss clay soil.

... Show More
Publication Date
Tue Sep 04 2018
Journal Name
Al-khwarizmi Engineering Journal
Effect of Carburization Parameters on Hardness of Carburized Steel Using MOORA Approach
...Show More Authors

In this research, (MOORA) approach based– Taguchi design was used to convert the multi-performance problem into a single-performance problem for nine experiments which built (Taguchi (L9) orthogonal array) for carburization operation. The main variables that had a great effect on carburizing operation are carburization temperature (oC), carburization time (hrs.) and tempering temperature (oC). This study was also focused on calculating the amount of carbon penetration, the value of hardness and optimal values obtained during the optimization by Taguchi approach and MOORA method for multiple parameters. In this study, the carburization process was done in temperature between (850 to 950 ᵒC) for 2 to 6

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of Pb percentage on optical parameters of PbxCd1-xSe thin films
...Show More Authors

PbxCd1-xSe compound with different Pb percentage (i.e. X=0,
0.025, 0.050, 0.075, and 0.1) were prepared successfully. Thin films
were deposited by thermal evaporation on glass substrates at film
thickness (126) nm. The optical measurements indicated that
PbxCd1-xSe films have direct optical energy gap. The value of the
energy gap decreases with the increase of Pb content from 1.78 eV to
1.49 eV.

View Publication Preview PDF
Crossref