Preferred Language
Articles
/
jbcd-2383
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Clinical And Experimental Dentistry
Comparison of the accuracy of intraoral digital impression system and conventional impression techniques for multiple implants in the full-arch edentulous mandible
...Show More Authors

View Publication
Scopus (7)
Crossref (10)
Scopus Crossref
Publication Date
Sat Jun 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of The Microleakage of Polyacid Modified Composite Compared to Hybrid Composite and Resin Modified Glass Ionomer Cement in Primary and Permanent Teeth Restoration (An in vitro study)
...Show More Authors

Background: Dental caries is one of the most significant problems in world health care. Restoring carious primary teeth is one of the major treatment goals for Children, and the light activated resin restoration materials like composite, resin-modified glass ionomer and polyacid-modified which was introduced in dentistry in 1970, widely used in clinical dentistry but its application increased dramatically in recent years because of its biocompatibility, color matching, good adhesive properties of its resemblance in physical and mechanical aspects to tooth. The aim of this study: To evaluate the microleakage of Polyacid-Modified Composite resin Compared to Flowable Hybrid Composite and Resin-Modified Glass ionomer cement. Materials and me

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Fri Oct 02 2020
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Extraction and Determination of Amygdaline in Iraqi Plant Seeds Using the Combined Simple Extraction Procedure and High-Performance Liquid Chromatography
...Show More Authors

Abstract :In this study, amygdaline in Iraqi plant seeds was extracted and isolated from their seeds matrix using reflux procedure and subsequently identified and determined by high performance liquid chromatography (HPLC) on reversed phase column of LC-18 (150mm x 4.6mm, 5?m )with actonitrile :water ( 50 : 50 ) as mobile phase at flow rate of ( 0.5 mL/min ) and detection at wavelength of 215 nm.The experimental results indicated that the linearity of calibration is in the range of 1.0-30.0 mg L-1amygdaline with the correlation coefficient of 0.9949. The limit of detection (LOD) and limit of quantitation (LOQ) for amygdaline were of 0.88 and 2.93 mg L-1 in standard pure sample. The mean recovery percent is 97.34±0.58 at 95% confidence inte

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Apr 28 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
COMPARISON OF TWO TYPES OF SENSORS AND THEIR EFFECT ON SPRAY QUALITY PEAR TREES
...Show More Authors

This study was aimed to reduce the amount of the sprayed solution lost during trees spraying.  At the same time, the concentration of the sprayed solution on the target (tree or bush) must be ensured and to find the best combination of treatments. Two factors controls the spraying process: (i) spraying speed (1.2 km/h, 2.4 km/h, 3.6 km/h), and (ii) the type of sensor. The test results showed a significant loss reduction percentage. It reached (6.05%, 5.39% and 2.05%) at the speed (1.2 km/h, 2.4 km/h, 3.6 km/h), respectively. It was noticed that when the speed becomes higher the loss becomes less accordingly. The interaction between the 3.6 km/h speed and the type of Ultrasonic sensor led to a decrease in the percentage of the spray

... Show More
Scopus Crossref
Publication Date
Sun Jul 01 1990
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
COMPARISON OF ALFALFA WEEVIL POPULATIONS UNDER EPIZOOTIC AND ENZOOTIC CONDITIONS OF ERYNIAPHYTONOMI IN WISCONSIN
...Show More Authors

Comparisons of two life tables constructed to display alfaifa weevil Hypera posticoa (Gryllenhal), populations in southeentral Wisconsin, U. S. A. under epizootic and enzootic conditions of fungal diseasea, caused by Erynia phytonomi Arthur suggests that the “prepupal” stage provided the greates contribution to population changes under both conditions due to the high mortality rate. The principle mortality agents during this stage are E. phytonomi and the parasitoids complex of Bathyp1ectes curculionis and Buthyp1ectes anurus respectively under the two condition.

View Publication Preview PDF
Publication Date
Wed May 01 2024
Journal Name
Journal Of Ecological Engineering
Explore the Impact of Surfactant Type on the Stability and Separation Efficiency of Oil–Water Emulsions of Real Wastewater from Al-Basrah Crude Oil Using Microbubble Air Flotation
...Show More Authors

Among several separation processes, the air flotation distinguish as remarkably high potential separation process related to its high separation efficiency and throughput, energy-efficient, simple process, cost-effective, applicable to a wide range of oily wastewater and no by-products. The current study aimed to investigate the effect of the type and concentration of surfactant on the stability of oil-water emulsion and efficiency of the separation process. For this purpose, three types of surfactant where used (anionic SDS, mixed nonionic Span 85/Tween 80, and cationic CTAB). The results demonstrated that the Span 85/Tween 80 surfactant has the best stability, and it increases with the surfactant concentration augmentation. The removal ef

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref