Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).
Exogenous levothyroxine dose modulation and euthyroidism achievement is a persistent challenge in clinical settings. This study strives to assess the adequacy of treatment and identify the patients’ factors that can be used to estimate the euthyroid levothyroxine dose. A secondary objective was to assess vitamin D supplementation impact on thyroid status.
A review of a prospectively collected information from 142 female patients from Baghdad Center of Nuclear Medicine from June 2019 until March 2020 who were receiving levothyroxine for different causes was done. After a follow-up period, the patients’ thyroid tests were assessed and the euthyroid doses for each cause category were statistically analyzed. Thyroid function was
... Show MoreThe Growth Differentiation Factor -15 (GDF-15) is a member of the transforming growth factor β superfamily. İt represents an example of the stress response cytokines. It's mostly found in cardiac myocytes, adipocytes, macrophages, endothelial cells, and vascular endothelial cells, whether they're generated normally or not. GDF-15 levels have increased and are associated with cardiovascular risk. Aim of the study: To investigate the correlation between angiotensin-converting enzyme (ACE) inhibitors and angiotensin II receptor blockers (ARBs) with the level of plasma GDF-15 in a group of hypertensive patients. Materials and methods: A case-control study involved 90 individuals, 60 hypertensive patients (36 on ACE inhibitors and 24 on ARBs)
... Show MoreRe-use of the byproduct wastes resulting from different municipal and industrial activities in the reclamation of contaminated water is real application for green projects and sustainability concepts. In this direction, the synthesis of composite sorbent from the mixing of waterworks and sewage sludge coated with new nanoparticles named “siderite” (WSSS) is the novelty of this study. These particles can be precipitated from the iron(II) nitrate using waterworks sludge as alkaline agent and source of carbonate. Characterization tests using X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) mapping revealed that the coating process was c
The phenomenon of spatial variation in the economic, social and urban development levels is considered prevalent in most of the economic and social systems,this relates to the concentration of most of those activities in certain regions and because of their rarity in other regions , that led to the emergence of the problem of the sharp contrast between the most developed areas and least developed areas within the same region or within the regions of the same country,
Reduction of this variables , in addition to the development of areas through following up and relying on an effective regional development enabling to reduce unemployment as well as to stop the migration of the unplanned for population,
And the ideal use of available
Background: Repeated teenage pregnancy is a major burden on the healthcare system worldwide. Objective: We aimed to compare teenagers with their first and third pregnancies and to evaluate the likelihood of neonatal complications. Materials and Methods: This cross-sectional study was performed on female teenagers (aged ≤ 19 yr) with singleton pregnancies. The subjects (n = 298) were screened over 12 months. Ninety-six women were excluded, based on the exclusion criteria. The remaining subjects (n = 202) were divided into two groups: teenagers with first pregnancy (n = 96) and teenagers with third pregnancy (n = 47). The subjects were observed throughout pregnancy and delivery. The final sample size of the first and thi
... Show MoreBACKGROUND: Femoral shaft fracture is a common fracture in pediatric age group reaching 62% of all fracture shaft femur in children in spite of rapid union rate and successful conservative treatment but some cases need surgical intervention and one of the methods using plate and screw by the lateral approach. AIM: This study aims to compare functional outcome fixation of mid-shaft femur fracture in children by plate and screws between (subvastus lateralis and transvastus lateralis) regarding infection, union, and limitation of knee movement. PATIENT AND METHOD: The study was done on 30 children who had diaphyseal fracture femur in Al-Kindy Teaching Hospital in period (April 2018–April 2020) with 6 months follow-up, and the pa
... Show MoreThe article provides a comparative analysis of comparisons in Russian and Arabic, aimed at identifying their structural, typological, and functional-pragmatic features. The study is based on a systematic approach to the analysis of linguistic means of expressing comparisons in two differ- ent linguistic cultures. The article analyzes the main structural components of comparisons, their classification, and their cognitive and aesthetic functions. The results of the study demonstrate the deep cultural conditioning of comparative constructions and their important role in representing the specific features of the respective linguistic cultures.
We propose a novel strategy to optimize the test suite required for testing both hardware and software in a production line. Here, the strategy is based on two processes: Quality Signing Process and Quality Verification Process, respectively. Unlike earlier work, the proposed strategy is based on integration of black box and white box techniques in order to derive an optimum test suite during the Quality Signing Process. In this case, the generated optimal test suite significantly improves the Quality Verification Process. Considering both processes, the novelty of the proposed strategy is the fact that the optimization and reduction of test suite is performed by selecting only mutant killing test cases from cumulating t-way test ca
... Show MoreThis paper proposes a new approach to model and analyze erect posture, based on a spherical inverted pendulum which is used to mimic the body posture. The pendulum oscillates in two directions, [Formula: see text] and [Formula: see text], from which the mathematical model was derived and two torque components in oscillation directions were introduced. They are estimated using stabilometric data acquired by a foot pressure mapping system. The model was quantitatively investigated using data from 19 participants, who were first were classified into three groups, according to the foot arch-index. Stabilometric data were then collected and fed into the model to estimate the torque’s components. The components were statistically proce
... Show More