Preferred Language
Articles
/
jbcd-2383
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
A Simulation of Core Displacement Experiments for the Determination of the Relative Permeability
...Show More Authors

Computations of the relative permeability curves were made through their representation by two functions for wetting and nonwetting phases. Each function contains one parameter that controls the shape of the relative permeability curves. The values of these parameters are chosen to minimize an objective function, that is represented as a weighted sum of the squared differences between experimentally measured data and the corresponding data calculated by a mathematical model simulating the experiment. These data comprise the pressure drop across core samples and the recovery response of the displacing phase. Two mathematical models are constructed in this study to simulate incompressible, one-dimensional, two-phase flow. The first model d

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Oct 30 2008
Journal Name
College Of Islamic Sciences
The love of the world and its lusts The preference and bliss of the Hereafter In Surat Al-Imran: "objective study"
...Show More Authors

The love of the world and its lusts are the head of sins and the corruptors of religion, and the one who loves and loves them who prefers them over the hereafter is one of the most pitiful of creation, and the least intelligent of them, as he prefers imagination over reality, sleep over wakefulness, fleeting shadow over eternal bliss and the mortal abode over the eternal abode, and he sold the life of eternity for the most luxurious life. In life, it is dreams and sleep or as a fleeting shadow, and as it was said: The intelligent person is not deceived.
The reason for choosing this topic is due to two things:
The first: When I contemplated the reasons for the differences and conflicts that afflicted our wounded and occupied country

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
The Datums Transformation for GPS Navigation Measurements Correction
...Show More Authors

The GPS navigation measurements become more widely used in many civilian and scientific application. All GPS navigation data holds many errors, the main error sources arise from the geodetic Datum variation when user apply the GPS measurements with the map. Geodetic datums define the size and shape of the earth and the origin and orientation of the coordinate systems used to map the earth surface. In this paper, the Datum transformation was evaluated in two mathematical methods to overcome the errors due to the difference between the WGS-84 and our country Datum Clarck-1880. The results was evaluated and investigated using Carmin GPS device for GCPs comparison, topographic map for Hilla city, mid Iraq 1:100000 scale, and two georefrencing

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 29 2021
Journal Name
College Of Islamic Sciences
Almzna given in the consolation of the Prophet)) for women- an objective stu
...Show More Authors

 My research deals with the positions that the Prophet (PBUH) distressed. And condolences to those who lost her father and other problems and calamities that impede the life of women, has been given to the Lord of men, and good qualities, to strike the nation's finest proverbs in ensuring lost and lost of women and children, to be shown to us humanity in its finest form, and the best analyzed, and I hope God help And guidance and Rashad

View Publication Preview PDF
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
A comparison of the Semiparametric Estimators model smoothing methods different using
...Show More Authors

In this paper, we made comparison among different parametric ,nonparametric and semiparametric estimators for partial linear regression model users parametric represented by ols and nonparametric methods represented by cubic smoothing spline estimator and Nadaraya-Watson estimator, we study three nonparametric regression models and samples sizes  n=40,60,100,variances used σ2=0.5,1,1.5 the results  for the first model show that N.W estimator for partial linear regression model(PLM) is the best followed the cubic smoothing spline estimator for (PLM),and the results of the second and the third model show that the best estimator is C.S.S.followed by N.W estimator for (PLM) ,the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 14 2026
Journal Name
Mustansiria Dental Journal
Soft tissue measurements of Iraqi individuals with Cl I and Cl III skeletal pattern: a comparative cephalometric study
...Show More Authors

View Publication
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Advanced Research
ON STABILITY AND THE BOUNDEDNESS OF THE ZERO SOLUTION OF FIFTH ORDER
...Show More Authors

This paper is illustrates the sufficient conditions of the uniformly asymptotically stable and the bounded of the zero solution of fifth order nonlinear differential equation with a variable delay τ(t)

Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Engineering
The Influence of the Preparation and Stability of Nanofluids for Heat Transfer
...Show More Authors

Recently the use of nanofluids represents very important materials. They are used in different branches like medicine, engineering, power, heat transfer, etc. The stability of nanofluids is an important factor to improve the performance of nanofluids with good results. In this research two types of nanoparticles, TiO2 (titanium oxide) and γ-Al2O3 (gamma aluminum oxide) were used with base fluid water. Two-step method were used to prepare the nanofluids. One concentration 0.003 vol. %, the nanoparticles were examined. Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and X-ray diffraction (XRD) were used to accomplish these tests. The stability of the two types of nanofluids is measured by

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Bioautomation
Model for Prediction of the Weight and Height Measurements of Patients with Disabilities for Diagnosis and Therapy
...Show More Authors

Background: Accurate measurement of a patient’s height and weight is an essential part of diagnosis and therapy, but there is some controversy as to how to calculate the height and weight of patients with disabilities. Objective: This study aims to use anthropometric measurements (arm span, length of leg, chest circumference, and waist circumference) to find a model (alternatives) that can allow the calculation of the height and the body weight of patients with disabilities. Additionally, a model for the prediction of weight and height measurements of patients with disabilities was established. Method: Four hander patients aged 20-80 years were enrolled in this study and divided into two groups, 210 (52.5%) male and 190 (47.5%) fe

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Wed May 02 2018
Journal Name
Chempluschem
The Oxidation of Peroxide by Disordered Metal Oxides: A Measurement of Thermodynamic Stability “By Proxy”
...Show More Authors

It is often noted that disordered materials have different chemical properties to their more “ordered” cousins. Quantifying these effects in terms of thermodynamics is challenging in part because disordered materials can be difficult to characterize and are frequently relatively unstable. During the course of our experiments to understand the effects of disorder in catalysts for water oxidation we observed that many disordered manganese and cobalt oxide water oxidation catalysts directly oxidized peroxide in contrast to their more ordered analogues which catalyzed its disproportionation, that is, MnO2+2H+ +H2O2! Mn2+ +2H2O+O2(oxidation) versus H2O2!H2O+1=2 O2(disproportionation). By measuring the efficiency for one reaction over the oth

... Show More
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref