Background: Determination of sex and estimation of stature from the skeleton is vital to medicolegal investigations. Skull is composed of hard tissue and is the best preserved part of skeleton after death, hence, in many cases it is the only available part for forensic examination. Lateral cephalogram is ideal for the skull examination as it gives details of various anatomical points in a single radiograph. This study was undertaken to evaluate the accuracy of digital cephalometric system as quick, easy and reproducible supplement tool in sex determination in Iraqi samples in different age range using certain linear and angular craniofacial measurements in predicting sex. Materials and Method The sample consisted of 113of true lateral cephalometric radiographs for adults with age range from 22-43 years old (51 males, 62 females), using certain linear and angular craniofacial measurements with the aid of computer program “AutoCAD 2007” Results: The eleven parameters measured for males and females when compared are statistically significantly different. All cranio-cephalometric measurements gave overall predictive accuracy of sex determination by discriminant analysis (86.7%). The stepwise selection method gave overall predictive accuracy of sex determination by discriminant analysis (85.8%). Age showed no statistical difference among the studied age range except for the distance from Mastoid to Frankfort plane. Conclusion: The lateral cephalometric measurements of craniofacial bones are useful to support sex determination of Iraqi population in forensic radiographic medicine.
This research has been prepared to isolate and diagnose one of the most important vegetable oils from the plant medical clove is the famous with Alaeugenol oil and used in many pharmaceuticals were the isolation process using a technique ultrasonic extraction and distillation technology simple
Face Identification system is an active research area in these years. However, the accuracy and its dependency in real life systems are still questionable. Earlier research in face identification systems demonstrated that LBP based face recognition systems are preferred than others and give adequate accuracy. It is robust against illumination changes and considered as a high-speed algorithm. Performance metrics for such systems are calculated from time delay and accuracy. This paper introduces an improved face recognition system that is build using C++ programming language with the help of OpenCV library. Accuracy can be increased if a filter or combinations of filters are applied to the images. The accuracy increases from 95.5% (without ap
... Show MoreThe Electrocardiogram records the heart's electrical signals. It is a practice; a painless diagnostic procedure used to rapidly diagnose and monitor heart problems. The ECG is an easy, noninvasive method for diagnosing various common heart conditions. Due to its unique advantages that other humans do not share, in addition to the fact that the heart's electrical activity may be easily detected from the body's surface, security is another area of concern. On this basis, it has become apparent that there are essential steps of pre-processing to deal with data of an electrical nature, signals, and prepare them for use in Biometric systems. Since it depends on the structure and function of the heart, it can be utilized as a biometric attribute
... Show MoreFive species of Lactic acid bacteriawere isolated from raw milk, yoghurt, vegetables and pickles, Lactobacillus plantarum, Lactobacillus acidophilus, Lactobacillus brevis, Lactobacillus casei and Lactobacillus bulgaricus isolates were identified by 16S rRNA gene. Evaluate of antimicrobial activity against all the bacterial strains Staphylococcus aureus, Salmonella spp., Pseudomonas fluorescens, Escherichia coli, Bacillus cereus and Bacillus subtilis. It showed that bacteriocin of Lactic acid bacteriamore effective than supernatant of lactic acid bacteria, the results showed that isolatemost efficient isolate belonging to Lactobacillus brevis, the diameter of the inhibition of the bacteriocin of Lactobacillus brevis were 27.7, 26.3 and 25.1
... Show MoreThis study was aimed to one of the most prevalent causes for endodontic treatment failure is the presence of Enterococcus faecalis bacterium within teeth root canals. To achieve successful treatment, it is so important to study E. faecalis behavior. The aim of study was to investigate biofilm production and antibiotic sensitivity of E. faecalis isolated from root canals. Results showed isolation of E. feacalis (65%) of samples, identified by specific gene by PCR technique. Most isolates were sensitive to Imipenem and resistant to Erythromycin, Clindamycin, Tetracycline and Trimethoprim. Strong biofilm production was detected among 29.5% of highest antibiotic resistant isolates. The results may indicate that infected root canals with E. feac
... Show MoreThe hydrolysis of urea by the enzyme urease is significant for increasing the irroles in human pathogenicity, biocementation, soil fertilizer, and subsequently in soil improvement. This study devoted to the isolation of urease from urea-rich soil samples collected from seven different locations. Isolation of the various bacterial species was conducted using nutrient agar. The identity of isolated urease was based on morphological characteristics and standard microbiological and biochemical procedures. The urease producing strains of bacteria were obtained using the urease hydrolysis test. The bacterial isolates produced from soil samples collected from different environments and treat
The digital camera which contain light unit inside it is useful with low illumination but not for high. For different intensity; the quality of the image will not stay good but it will have dark or low intensity so we can not change the contrast and the intensity in order to increase the losses information in the bright and the dark regions. . In this search we study the regular illumination on the images using the tungsten light by changing the intensities. The result appears that the tungsten light gives nearly far intensity for the three color bands(RGB) and the illuminated band(L).the result depend on the statistical properties which represented by the voltage ,power and intensities and the effect of this parameter on the digital
... Show MoreThe research aims to estimate missing values using covariance analysis method Coons way to the variable response or dependent variable that represents the main character studied in a type of multi-factor designs experiments called split block-design (SBED) so as to increase the accuracy of the analysis results and the accuracy of statistical tests based on this type of designs. as it was noted in the theoretical aspect to the design of dissident sectors and statistical analysis have to analyze the variation in the experience of experiment )SBED) and the use of covariance way coons analysis according to two methods to estimate the missing value, either in the practical side of it has been implemented field experiment wheat crop in
... Show MoreThe performance measures and traditional methods used in management accounting is no longer able to provide convenient to evaluate the performance of economic units in the modern manufacturing environment information، and so this information is more important and feasibility must be Mistohat of all the company's activities and functions، and it is a problem Find the inadequacy of information management accounting that contribute to meet the needs of the upper levels of management to cope with the problems resulting from the increased size and complexity of the business، and lack of management accounting information and methods used in the performance evaluation، which reflected negatively on the value chain activities and then on the
... Show MoreThe aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x