Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by means of conventional instruments for hand use (Dentsply, Switzerland) up to size 35.then root canal filling was performed followed by post space preparation up to 8mm including cervical and middle one third of root canal then the fiber post was cemented into canal post space then the root was sectioned to get cervical (4 mm in length) and middle (4 mm in length) thirds ,these thirds were examined by push out test to get values of retention of fiber post inside these canal thirds . Results and Conclusions: The results of this study has been showed that there was no significant differences between push out bond strength between fiber post and root at cervical third as compared with middle third when using polycarboxylate cement or Zinc phosphate cement to cement the fiber post to the canal walls and the results showed that there was no significant differences in push out bond strength for polycarboxylate or Zinc phosphate cement after one and two months but there was highly significantly increase in push out bond strength for resin cements used to cement the fiber post to the root canal after one and two months
Background: Echocardiography has an important role to follow up patients with Iatrogenic atrial septaldefect (IASD) and after Catheter ablation during electro-physiological study.Objectives: evaluating the impact of non-invasive Transthoracic Echocardiography (TTE) parameters(LAVI, LVEF, ASD size and E/e`) post radiofrequency ablation of left atrial arrhythmia.Patients and methods: for the evaluation of the atrial septal defect, a transthoracic echocardiography(TTE) was used in patients who underwent left atrial arrhythmia ablation, enrolled in prospective studyin the Iraqi center for cardiac diseases, in cooperation with university of Baghdad /college of medicineResults: The outcomes of the present study were assessed according to
... Show MoreCurrently and under the COVID-19 which is considered as a kind of disaster or even any other natural or manmade disasters, this study was confirmed to be important especially when the society is proceeding to recover and reduce the risks of as possible as injuries. These disasters are leading somehow to paralyze the activities of society as what happened in the period of COVID-19, therefore, more efforts were to be focused for the management of disasters in different ways to reduce their risks such as working from distance or planning solutions digitally and send them to the source of control and hence how most countries overcame this stage of disaster (COVID-19) and collapse. Artificial intelligence should be used when there is no practica
... Show MoreThe present work includes the preparation and characterization of{Co(II) , Ni(II), Pd(II), Fe(III) , Ru(III),Rh(III), Os(III) , Ir(III) , Pt(IV) and VO(IV)}complexes of a new ligand 4-[(1-phenyl-2,3-dimethyl-3-pyrozoline-5-one)azo]-N,N-dimethylanline (PAD). The product (PAD) was isolated,studies and characterized by phsical measurements,i.e., (FT-IR), (UV) Spectroscopy and elemental analysis(C.H.N). The prepared complexes were identified and their structural geometric were suggested in solid state by using flame atomic absorption, elemental analysis(C.H.N), (FT-IR) and (UV-Vis) Spectroscopy, as well as magnetic susceptibility and conductivity measurements . The study of the nature of the complexes formed in( ethanolic solution) following t
... Show MoreIn the present study, a novel ligand (L) made of 2-hydroxynaphthaldehyde and 3-hydrazone-1,3-dihydro-indole-2-one(3-[(3-hydroxynaphthalen-2-yl-ethylidene)-hydrazono]-1,3-dihydro-indol-2-one). The ligand was characterized by FTIR, UV-vis, mass, 1H-NMR, 13C-NMR, and CHN elemental analysis. New complexes of this ligand were created by treating methanol and a drop of DMF solution of the produced ligand with the hydrated metal salts of Mn(II), Co(II), Ni(II), Cu(II), and Zn(II) in a molar ratio of 2:1 (L:M). As a result, complexes have been emerged and identified FTIR, UV-vis, C.H.N., chloride-containing, molar conductance, magnetic susceptibility, and atomic absorption. The characterization result for each complex indicated complexes wi
... Show MoreThe effect of some environment faetor (different temperature and relative humidity) on the biology of the old world- screw worm, were studied under laboratory condition, the result showed that non of the eggs hatched at 15°c and under dried eondition which relative humidity between 20-40%, also result showed that the mature larvae needs one days to become pupa since it leaves the larval died at the temperature ranged between 25-40°C at different humidity rates. While it needs 3 days under lower temperature and different humidity to become pu^, on the other hand the results showed that either low temperature and dried condition or high temperature at different humidity rates cause non of pupa became adult. While low temperature (15-20) °c
... Show MoreChoosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show MoreABSTRACT
Background : The aim of this work is to assess the role of breast sonography and ductography in the evaluation of different causes of nipple discharge.
Methods : The study will be carried out on twenty-five female patients referred to the Radiodiagnosis department at Alexandria Main University Hospital presenting with nipple discharge.
They were divided into two groups:
Group I include 10 patients (40%) with surgically significant nipple discharge who were the patients with unilateral, uniorificial surgically significant colour type nipple discharge .They were investigated by mammography, sonography, and ductography.
Group II include 15 patients
... Show MoreBackground: The marginal fit is the most characteristic that closely related to the longevity or success of a restoration, which is absolutely affected by the fabrication technique. The objective of present in vitro study was to evaluate the effect of four different CAD/CAM systems on the marginal fit of lithiµm disilicate all ceramic crowns. Materials and Methods: Adentoform tooth of a right mandibular first molar was prepared to receive all ceramic crown restoration with deep chamfer finishing line (1mm) and axial reduction convergence angle of 6 degree, dentoform model duplicated to have Nickel-Chromiµm master die. Thirty two stone dies produce from master die and distributed randomly in to four groups (8 dies for each group) accor
... Show More