Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by means of conventional instruments for hand use (Dentsply, Switzerland) up to size 35.then root canal filling was performed followed by post space preparation up to 8mm including cervical and middle one third of root canal then the fiber post was cemented into canal post space then the root was sectioned to get cervical (4 mm in length) and middle (4 mm in length) thirds ,these thirds were examined by push out test to get values of retention of fiber post inside these canal thirds . Results and Conclusions: The results of this study has been showed that there was no significant differences between push out bond strength between fiber post and root at cervical third as compared with middle third when using polycarboxylate cement or Zinc phosphate cement to cement the fiber post to the canal walls and the results showed that there was no significant differences in push out bond strength for polycarboxylate or Zinc phosphate cement after one and two months but there was highly significantly increase in push out bond strength for resin cements used to cement the fiber post to the root canal after one and two months
This study evaluates the flexural behavior of ultra-thin (50 mm) one‑way reinforced‑concrete (RC) slabs retrofitted with near‑surface mounted (NSM) carbon‑fiber‑reinforced polymer (CFRP) rods under quasi‑static loading. T300‑grade CFRP rods (≈4 mm diameter) were bonded in pre‑cut 7 mm × 7 mm grooves using a two‑part epoxy. As a proof-of-concept experimental baseline, three simply‑supported specimens (1000 mm × 500 mm × 50 mm) were tested in a six‑point bending configuration (four applied loads + two reactions): two conventional controls and one strengthened slab. A load‑control rate of ~15 kN/min was applied; the controls were cycled twice and the strengthened slab four times. Relative to the average of
... Show MoreBackground and Aim. Coronary artery disease (CAD) is a major risk factor for the progression to heart failure (HF), which is associated with an increase in left ventricular volume (LVV). This study aims to measure ventricular function and myocardial perfusion imaging markers of the left side of the heart, which can be performed with injection of a 99mTc at stress and rest by using single-photonemission-computed-tomography (SPECT). Subject and methods. The study included 121 patients with CAD, comprising 53 females and 68 males with ages between 25 to 88 years and 265 healthy subjects comprising 84 males and 181 females. All patients and healthy subjects volunteered to participate in this study. They were classified according to
... Show MoreGiven the growing interest in digital marketing operations and the technology imposed by the reality in which both companies and their customers are affected, the researchers attempted to shed light on the reality and challenges of digital marketing from the faculty members viewpoint at Jouf university, the problem is that technology has imposed a new reality that has resulted in a major change in behavioral patterns of customers with a number of obstacles and challenges confronted customers in digital marketing, it is expected that the outcomes of this study help companies in overcoming the obstacles that prevent the desire and ability of the customer to change his behavioral style to deal with electronic shopping operations and
... Show MoreExposure of reinforced concrete buildings to an accidental fire may result in cracking and loss in the bearing capacity of their major components, columns, beams, and slabs. It is a challenge for structural engineers to develop efficient retrofitting techniques that enable RC slabs to restore their structural integrity, after being exposed to intense fires for a long period of time. Experimental
investigation was carried out on twenty one slab specimens made of self compacting concrete, eighteen of them are retrofitted with CFRP sheets after burning and loading till failure while three of them (which represent control specimens) are retrofitted with CFRP sheet after loading till failure without burning. All slabs had been tested in a
Importance of accounting standards belong to be the instructor and the advisor for accountant in performing his work . For each invironment a group of political, social, economical and cultural factors which distinguish it about other environments . In order to perform its aim in produsing accouting information helps in making decisions on different levels, accounting standards should established in a form that harmonized with the environment that apply in it . Establishing international accounting standards comes with the same direction and then it has put influential with standards some states that have influence on international accounting standards committee. So because of the big changes that happened in the inte
... Show MoreIn this study, a system of nonthermal plasma that was operated under atmospheric pressure and was powered by argon gas was employed. The particular plasma properties are affected by changes in the Ar gas flow ranges from 0.5 to 2.5 l/min, product by stream of the plasma jet that is utilized. By using the aforementioned method generated from AC and DC. After placing Ar gas as the cathode, which represents the negative pole, flows toward the anode, which is represented by a tiny metal plate of Zn measuring 6 × 1 cm2 in size, with a submerged part of 4 cm2 long, with both types of current employed having a high voltage of 13.5 kV and the frequency of AC was 30 kHz, we measured these variable parameters. It has been shown that when argon f
... Show MoreThis work concerned on nanocrystalline NiAl2O4 and ZnAl2O4 having spinel structure prepared by Sol–gel technique. The structural and characterization properties for the obtained samples were examined using different measurements such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), finally, Field emission scanning electron microscope (FESEM).The Spinel-type for two prepared compound (NiAl2O4) and (ZnAl2O4) at different calcination temperature examined by XRD. Williamson-Hall Methods used to estimate crystallite size, Average distribution crystallite size of two compound were, 34.2 nm for NiAl2O4 and32.6 for ZnAl2O4, the increase in crystallite size affecting by increasing in calcination temperature for both comp
... Show More