Preferred Language
Articles
/
jbcd-223
The effect of different finishing and polishing systems on surface roughness of new low polymerized composite materials (An in vitro study)
...Show More Authors

Background: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surface polish and were subdivided into A1 (Giomer) and A2 (Tetric®N-Ceram). Group B: 10 specimens received polishing with Air polishing devise (APD) and were subdivided into B1 (Giomer) and B2 (Tetric®N-Ceram). Group C: 10 specimens received polishing with pumice and brush and were subdivided into C1 (Giomer) and C2 (Tetric®N-Ceram). Group D: 10 specimens were polished with pumice and rubber cup and were subdivided into D1 (Giomer) and D2 (Tetric®N-Ceram). Testing was done by means of profilometer and statistically analyzed using analysis of variance test (ANOVA), LSD and student t-test. Also samples were photographed by special orthoplane camera using light polarizing microscope. Results: The results showed a highly statistical significant difference in surface roughness among Giomer subgroups P<0.05. Also there was a highly significant difference P<0.05 when comparing Tetric subgroups according to type of surface treatment. Furthermore there was non-significant difference P>0.05 between groups according to the type of restorative material used. Conclusion: The use of prophylactic surface treatment significantly increased Giomer and Tetric ceram surface roughness and the use of rotating brush has shown the roughest surface among all other types of prophylactic protocols also Giomer had shown more surface roughness than Tetric ceram although the difference was not significant.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Apr 11 2024
Journal Name
Euphrates Journal Of Agriculture Science
Effect of cultivars and irrigation periods on some growth and yield indicators for watermelon
...Show More Authors

Publication Date
Fri Aug 18 2023
Journal Name
Journal Of Research In Medical And Dental Science
Morphologic Evaluation of the Permanent Mandibular First Molar within an Iraqi Population Using Cone Beam Computed Tomography (Retrospective Study)
...Show More Authors

Preview PDF
Publication Date
Wed Nov 08 2023
Journal Name
Aip Conf. Proc.
Correlation of Mercury With Some Biochemical Parameters in Serum of Mothers and Their New Born Children
...Show More Authors

Scopus
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Biology, Agriculture And Healthcare
Histopathological Changes of Some Internal Organs of Mice Injected with Exotoxin a at Low Concentrations
...Show More Authors

Abstract Exotoxin A is the most lethal virulence factor produced by Pseudomonas aeruginosa. It inhibits elongation factor-2 by ADP-ribosylation of EF2. This causes stop of the elongation of polypeptides. In recent study, the effect of low concentration of exotoxin A on some important internal organs of mice was studied. Four groups white mice were injected intraperitonialy with pure exotoxin A in the following manner 0.1, 0.2, 0.3, 0.4 ng\ animals. One mouse receives normal saline inrtaperitonialy as a control. After 72 hours the mice were killed and four organs were taken, liver, spleen, lung and heart from each killed mice. Histological sections were made from each organ and stained with hematoxylin and eosin stain then examined under mic

... Show More
Publication Date
Mon Apr 01 2024
Journal Name
Latin American Journal Of Pharmacy
The protective effect of iraqi Juniperus oxycedrus plant on acute kidney injury induced by lipopolysaccharide in mice model
...Show More Authors

Inflammatory control is essential to diminish injury and make renal injury treatment simpler. Proposed therapeutics have primarily targeted pro-inflammatory variables. Juniperus oxycedrus was frequently used to treat a variety of infectious disorders, hyperglycemia, obesity, TB, bronchitis, inflammation, and pneumonia. Juniperus oxycedrus twigs and leaves were defatted with n-hexane using Soxhlet apparatus then the residue of plant material dried and re-extracted sequentially by two different solvents Ethylacetate and methanol. The pro-inflammatory markers IL-1 and iNOS, as well as the potential kidney biomarker KIM-1, TNF-α, and transcription factor NF-KB were measured using the RealTime Quantitative qPCR method. The results showed that J

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Key Engineering Materials
Effect of Cold Plasma on the Levels Mineral Blood Components &lt;i&gt;In Vivo&lt;/i&gt;
...Show More Authors

This study illustrates effect of cold plasma CAP on the mineral blood components in vivo. the mineral blood component (Ca, Na, Cl, K and Fe) are used. Floating Electrode-Dielectric Barrier Discharge (FE-DBD) system of probe diameter 4cm is used for this purpose, and variable voltage (0-20) kV and variable frequency (0-30) kHz, the output power was ranged from (10 - 70) W. the effect of cold atmospheric plasma on mineral blood is studied with different exposure durations (30,45,60) sec. As the plasma exposure duration increases, the calcium, potassium and iron components in the blood increased, while The sodium and chlorine elements decreased. These results give an indication of the cold plasma receptor to be used to treat many disea

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Proceedings Of Ieee East-west Design &amp; Test Symposium (ewdts 2014)
Qubit method for diagnosing digital systems
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jul 02 2017
Journal Name
Journal Of Educational And Psychological Researches
The Effect of Carin Model in The Achievement of The First Intermediate Grade Students and Their Reflective Thinking in Physics Subject.
...Show More Authors

The Current research aims to identify ( the effect of Carin model in the achievement of the first intermediate Grade Students and their Reflective Thinking in physics Subject ) the researcher selected the experimental design with a partial adjust , The research sample consisted of ( 47 ) Students with ( 23 ) Students in the experimental group and ( 24 ) Students in the control group , The two groups rewarded in the variables chronological age in months , Reflective Thinking and the degrees in physics in the first course. The researcher coined the purposes of behavioral which belong to chapter fifth, sixth, and seventh of physics books scheduled of the school year ( 2015-2016 ) and prepared appropriate lesson plans for the two experimenta

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 21 2026
Journal Name
Journal Of Physical Education
The Effect of Inclusion Style Using Electronic Device On Learning Front and Side Movement in Squash For Beginners Aged 13 – 15 Years Old
...Show More Authors

View Publication
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Study The Influence of Forming Conditions Like Deformation Speed on Void Closure in Open Die Forging
...Show More Authors

This paper presents an investigation to the effect of the forming speed on healing voids that inhabit at various size in an ingot. The study was performed by using finite element method with bilinear isotropic material option, circular type voids were considered. The closure index was able to predict the minimum press force necessary to consolidate voids and the reduction. The simulation was carried out, on circular cross-section lead specials containing a central void of different size. At a time with a flat die, different ratio of inside to outside radius was taken with different speed to find the best result of void closure.

View Publication Preview PDF