Background: The integration of modern computer-aided design and manufacturing technologies in diagnosis, treatment planning, and appliance construction is changing the way in which orthodontic treatment is provided to patients. The aim of this study is to assess the validity of digital and rapid prototyped orthodontic study models as compared to their original stone models. Materials and methods: The sample of the study consisted of 30 study models with well-aligned, Angle Class I malocclusion. The models were digitized with desktop scanner to create digital models. Digital files were then converted to plastic physical casts using prototyping machine, which utilizes the fused deposition modeling technology. Polylactic acid polymer was chosen as the printing material. Twenty four linear measurements were taken from digital and prototyped models and were compared to their original stone models “the gold standardâ€, utilizing the paired sample t-test and Bland-Altman plots. Results: Eighteen of the twenty four variables showed non-significant differences when digital models were compared to stone models. The levels of agreement between the two methods showed that all differences were within the clinically accepted limits. For prototyped models, more than half of the variables differed in non-significant amount. The levels of agreement were also within the clinically accepted limits. Conclusion: Digital orthodontic study models are accurate in measuring the selected variables and they have the potential to replace conventional stone models. The selected rapid prototyping technique proved to be accurate in term of diagnosis and might be suitable for some appliance construction.
Abstract
Due to the lack of previous statistical study of the behavior of payments, specifically health insurance, which represents the largest proportion of payments in the general insurance companies in Iraq, this study was selected and applied in the Iraqi insurance company.
In order to find the convenient model representing the health insurance payments, we initially detected two probability models by using (Easy Fit) software:
First, a single Lognormal for the whole sample and the other is a Compound Weibull for the two Sub samples (small payments and large payments), and we focused on the compoun
... Show MoreAccess to high-quality neurosurgery online learning is limited in low- and middle-income countries, and Iraq is part of this category. The need for collaboration and connection of people worldwide to exchange ideas and experiences in neurosurgery is a challenge. Surgical Neurology International® (SNI)/SNI Digital stimulated the establishment of the joint effort to bring the discussion about the best experiences in neurosurgery from the United States and Iraq together in an internet meeting format.
An online survey was formulated and distributed to the attendees of the SNI-Baghdad neurosurgery
WA Shukur, journal of the college of basic education, 2011 The aim of this research is designing and implementing proposed steganographic method. The proposed steganographic method don’t use a specific type of digital media as a cover but it can use all types of digital media such as audio, all types of images, video and all types of files as a cover with the same of security, accuracy and quality of original data, considering that the size of embedded data must be smaller than the size of a cover. The proposed steganographic method hides embedded data at digital media without any changing and affecting the quality of the cover data. This means, the difference rate between cover before hiding operation and stego is zero. The proposed steg
... Show MoreBackground: The need of the patient for a more reasonable esthetic orthodontic intervention has risen nowadays. Thus, orthodontists make use of esthetic orthodontic materials like brackets, ligature elastics, and arch wires. The esthetic brackets come as different forms of materials, such as ceramic brackets, which have their stainability remaining as the most important consideration for the patients and the orthodontists. This study aimed to compare the staining effects of various staining materials, including black tea, cigarette smoke and Pepsi, as well as the time effect on the color stability of sapphire ceramic brackets bonded with three kinds of light cure orthodontic adhesives: Transbond, Resilience and Enlight. Materials and Met
... Show MoreThis study aimed to evaluate the effect of the COVID-19 outbreak on emergencies and pain among orthodontic patients attending a teaching hospital. The study was conducted among orthodontic patients receiving active orthodontic treatment or in a retention period at the College of Dentistry, University of Baghdad, Iraq. Their participation was voluntary, and they filled out an Arabic-translated questionnaire. The survey included general information, orthodontic problems, and a numerical rating scale for pain assessment. We used descriptive and inferential statistics (frequencies and intersecting frequencies), chi-square test and linear regression. Out of 75 orthodontic patients, only 54 (15 males and 39 females) were included in the s
... Show MoreBackground: Orthodontic therapy often causes external root resorption. Serum vitamin D (VD) level is important for tooth mineralization and bone remodeling. This study aimed to test the impact of vitamin D (VD) supplements on bone and root remodelling in a vitamin D (VD) deficient rat model following orthodontic retention. Methods and Material: 30 male Wistar rats were divided into three groups: a control group of 10 rats and two experimental groups of 10 rats each with vitamin D deficiency (VDD) induced by a VD-free diet for 21 days. And a third group with VD supplementAll groups received orthodontic active treatment using a modified orthodontic appliance that applied 50 gm of force for 14 days to move the maxillary right first mol
... Show MoreBackground: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.
... Show MoreTemporomandibular disorders (TMDs) were investigated in 143 pretreatment orthodontic patients (43 males and 102 females) whose age ranged between 10-25 years at the College of Dentistry, University of Baghdad, Iraq. The study was undertaken to elucidate the prevalence and severity of TMDs in malocclusion patients and to defme the relationships between malocclusion and TMDs. The clinical signs and subjective symptoms were recorded according to the principles introduced by Helkimo (1974b). Subjective symptoms were reported by 65.7% of the patients with 22.40/0 described as severe, and the most common symptoms were TMJ sounds and feeling offatigue. Clinical signs were observed in 81.8% of the sample with 22.4 and 6.3% described as moderate and
... Show More