Preferred Language
Articles
/
jbcd-2210
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness varying from 1mm to 10mm in steps of 1mm each. The tested materials were radiographed, we used Image J software, on a computer screen to evaluate the degree of radiopacity for each individual material and compare with the aluminum step wedge. Radiopacity was expressed in mm of equivalent aluminum step wedge. Analysis of varience (ANOVA) and Least Significant Difference (LSD) were used to investigate the significance of differences among the tested groups. Results: Statistical analysis showed highly significant difference among the tested groups (p≤0.01). Amongst, G-aenial composite shows the most radiopaque and it is above or equivalent to that of enamel, while Estelite Sigma Quick composite has the lowest radiopacity value and is equivalent to that of dentin. Conclusion: In line with previous studies, and within the limitation of our study, considerable variations in radiopacity values were found among materials depending on the radiopaque elements incorporated into the matrix. All composite materials tested complied with the ISO 4049 standard.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 11 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of thermocycling and different pH of artificial saliva on the impact and transverse strength of heat cure resin reinforced with silanated ZrO2 nano-fillers.
...Show More Authors

Background: The aim of this study was to evaluate the effect of thermo cycling and different pH of artificial saliva (neutral, acidic, basic) on impact and transverse strength of heat cure acrylic resin reinforced of with 5% silanated ZrO2 nano fillers. Materials and methods: 120 samples were prepared, 60 samples for impact strength test and another 60 samples for transverse strength test, for each test, samples were divided into two major groups (before and after thermo cycling), then each of these major groups were further subdivided into 3 subgroups according to the pH of prepared artificial saliva (neutral, acidic, basic). Charpy impact device was used for impact strength test and Flexural device was used for transverse strength test. R

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Assessing Quality of Life Among Patients with Diabetes Mellitus, Hypertension or Both Diseases in Al-Najaf Province /Iraq
...Show More Authors

this study deals with effect of diabetes and hypertension on quality of life

View Publication Preview PDF
Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Color stability of nano resin-modified glass Ionomer restorative cement after acidic and basic medications challenge
...Show More Authors

Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over a thr

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Color stability of nano resin-modified glass Ionomer restorative cement after acidic and basic medications challenge
...Show More Authors

Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Tue Mar 13 2018
Journal Name
Mustansiria Dental Journal
Dimensional stability of heat-activated acrylic resin at different time intervals by different flask cooling methods
...Show More Authors

This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an

... Show More
Preview PDF
Publication Date
Wed Sep 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of plasma treatment on the bond of soft denture liner to conventional and high impact acrylic denture materials
...Show More Authors

Background: The main drawback of soft lining materials was that they debonded from the denture base after a certain period of usage. Therefore, the purpose of this research was to determine the impact of oxygen and argon plasma treatment on the shear bonding strength of soft liners to two different kinds of denture base materials: conventional acrylic resin and high impact acrylic resin. Materials and Methods: Heat cure conventional and high impact acrylic blocks (40 for each group) were prepared. A soft liner connected the final test specimen of two blocks of each acrylic material. Shear bond strength (SBS) was assessed using universal testing machine. Additional blocks were also prepared for analyzing Vickers microhardness, contact ang

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (4)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Effect of BaTio3 mixture on the structural, electrical properties and morphology for PET/ BaTiO3 composite
...Show More Authors

In the present work, the focusing was on the study of the x-ray diffraction, dielectric constant, loses dielectric coefficient, tangent angle, alter- natively conductivity and morphology of PET/BaTio3. The PET/BaTio3 composite was prepared for polyethylene terephthalate PET polymer composite containing 0, 10, 20, 30, 40, 50, and 60 wt. % from Barium titanate BaTi03 powder. The composite of two materials leads to form mixing solution and hot-pressing method. The effect of BaTio3 on the structure and dielectric properties with morphology was studied on PET matrix polymer using XRD, LCR meter and SEM.

View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Structures
Behaviour and design of the ‘lockbolt’ demountable shear connector for sustainable steel-concrete composite structures
...Show More Authors

In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the t

... Show More
View Publication Preview PDF
Scopus (35)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Iosr Journal Of Computer Engineering (iosr-jce)
A New Approach to DNA, RNA, and Protein Motifs Templates Visualization and Analysis via Compilation Technique
...Show More Authors

Motifs template is the input for many bioinformatics systems such codons finding, transcription, transaction, sequential pattern miner, and bioinformatics databases analysis. The size of motifs arranged from one base up to several Mega bases, therefore, the typing errors increase according to the size of motifs. In addition, when the structures motifs are submitted to bioinformatics systems, the specifications of motifs components are required, i.e. the simple motifs, gaps, and the lower bound and upper bound of each gap. The motifs can be of DNA, RNA, or Protein. In this research, a motif parser and visualization module is designed depending on a proposed a context free grammar, CFG, and colors human recognition system. GFC describes the m

... Show More
Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Writing of a Bragg Grating on a D-shaped Optical Fiber Using the KrF Excimer Laser
...Show More Authors

Fiber Bragg Grating has many advantages where it can be used as a temperature sensor, pressure sensor or even as a refractive index sensor. Designing each of this fiber Bragg grating sensors should include some requirements. Fiber Bragg grating refractive index sensor is a very important application. In order to increase the sensing ability of fiber Bragg gratings, many methods were followed. In our proposed work, the fiber Bragg grating was written in a D-shaped optical fiber by using a phase mask method with KrFexcimer. The resultant fiber Bragg grating has a high reflectivity 99.99% with a Bragg wavelength of 1551.2 nm as a best result obtained from a phase mask with a grating period of 1057 nm. In this work it was found that the rota

... Show More
View Publication Preview PDF