Background: The displacement of artificial teeth during complete denture construction presents major processing errors in the occlusal vertical dimension which were verified at the previous trial denture stage. The aim of this study was to assess the effect of delay in processing after final flask closure and tension application on the vertical acrylic and porcelain teeth displacement of complete dentures constructed from heat cured acrylic and the results were compared with the conventional processing method. Materials and methods: forty samples of identical maxillary complete dentures were constructed from heat polymerized acrylic resin. These samples were subdivided into the following experimental subgroups in which each subgroup contains 5 samples for both acrylic and porcelain teeth and as follows: 1. Conventional flasking technique and immediate processing. 2. Conventional flasking technique and 6 hours delay in processing. 3. flasking technique with tension system and immediate processing. 4. flasking technique with tension system and 6 hours delay in processing. Reference metal pins were attached to the middle of the buccal surface of the upper right canine and center of the buccal groove of the left first molar. And according to these reference points on the teeth another metallic Reference pins were fixed on the denture vestibules and at a distance of 7.5mm by straight lines and 6.5mm where placed between the metal pins and the vestibules in order to standardize the measurement. The distance between the right and left metal pins on the canine and molars and the corresponding metal pins on the buccal vestibules were measured during the wax up stage and after processing by using an optical travelling microscope with an accuracy of 0.0005 mm. Means in (mm) were analyzed statistically by analysis of variance and the comparative T-test and least significance test (LSD). Results: Significant reduction in vertical displacement of the teeth occurred in groups when 6 hours delay in processing were applied, but a significant improvement was also observed in groups with tension system application when compared with control group. On the other hand, there were a high significant reduction in the vertical displacement in groups with tension system and 6 hours delay in processing combination. While for the type of artificial teeth data showed significant difference in the amount of vertical displacement of the teeth in groups with acrylic teeth when compared with porcelain teeth. Conclusions: The findings of this study showed that 6 hours delay in processing and tension system application were effective in reducing the vertical displacement of the artificial teeth during flasking. The maximum reduction in the displacement was observed in dentures constructed from acrylic teeth. On the other hand, significant decrease in vertical displacement of the teeth was detected in dentures constructed from porcelain teeth.
This research attempts to evaluate the role of the information system by highlighting its importance in providing date and information to the tax administration the process of tax accounting for those who are subject to income tax whether they are individuals or companies where the effective information system provides accurate and reliable information in a timely manner.
At the theoretical part of the research, the research approaches the problem of the research represented in that whether the information system, applied in the General Commission for Taxes, is capable of achieving its role in reducing the phenomenon of tax evasion. The existence of a set of things which in the Commission may lead to increase tax evasion by taxpa
... Show MoreThe clinical response to natalizumab in patients with multiple sclerosis (MS) may be significantly influenced by genetic variation. Mutations in genes related to the drug’s mechanism of action or the pathological milieu of MS can contribute substantially to interindividual differences in treatment outcomes. This review aims to provide an overview of previous studies that have examined genetic polymorphisms associated with the clinical efficacy of natalizumab. A systematic literature search was conducted across the PubMed, Google Scholar, and ResearchGate databases using targeted keywords relevant to the subject matter. Several genetic loci were found to be linked to natalizumab responsiveness, including the integrin subunit alpha 4 (ITGA4
... Show MoreBackground: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.
Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)
Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO
... Show MoreThe effect of insecticide lamda cyhalothrin on Allium cepa L.root meristem were studied cytogenetically .Using three concentrations of the insecticide 5%, 7.5%, 10% at 6,12,24hours treatments . The insecticide significantly reduced the mitotic index at all concentrations. Moreover showed its ability to induced C – metaphase in 10% .The effects were also caused chromosome aberration like stickness in anaphase, telophase, binucleated cells, Micronuclei formation. These alternations indicating that this insecticide was effective in producing disturbance of spindle fibers.
In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar
... Show MoreKnowing the Messengers, peace and blessings be upon them, and explaining their obligatory, impossible, and permissible qualities is a legal necessity. It is a rooting of the faith, a means of understanding the Sharia, and a preventer from falling into the scourge of denial and bad manners against them. Therefore, sound belief in their presence is a major reason for the validity of the faith in the aspect of divinity and unseen hearing. Studying the status of prophethood is an urgent necessity in a time in which knowledge is scarce and attachment to the Messenger, may God Almighty’s prayers and peace be upon him, his family, and his companions, is weak, and suspicions and ideas hostile to the faith abound until we begin to hear - unfort
... Show MoreThe role of the ABC system in determining the costs of services in Iraqi banks