Preferred Language
Articles
/
jbcd-2209
In Vitro The Effect of Canals Instrumented With Three Rotary Ni-Ti Systems on The Dislocation Resistance of Guttafusion® Versus Single Cone Obturation Technique
...Show More Authors

Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly into three main groups, twenty roots in each group. The roots were instrumented with different rotary systems using crown down technique according to the groups: (Group I) was instrumented with WaveOne files. (Group II) was instrumented with ProTaper Next system and (Group III) was instrumented with ProTaper Universal system. For each group the same irrigation regimen was used, 3 mL of 5.25% sodium hypochlorite and 3 mL of 17% EDTA to remove the smear layer. Then, Group I was also subdivided randomly into two subgroups of ten samples each, (Group I A) obturated with single cone gutta-percha and (Group I B) filled with GuttaFusion®. Group II was divided into (Group II A) obturated with single cone gutta-percha and (Group II B) filled with GuttaFusion®. Group III was divided into (Group III A) obturated with single cone gutta-percha and (Group III B) obturated with GuttaFusion®. In the present study, TotalFill BC sealer was used for all the tested groups. Then, the roots were embedded in clear acrylic resin and each root sectioned into three sections of 2mm thick (apical, middle and coronal). The push-out bond strength values represented by (MPa) unit was calculated by dividing the load on the surface area and the last was measured in collaboration with AutoCAD system software program. Failure mode analysis was carried out to examine the type of failure in each sample by using a stereomicroscope. Results: The results showed highly significant differences among the main groups that instrumented with different rotary systems (WaveOne, ProTaper Next and ProTaper Universal system). There were highly significant differences between the two obturation techniques of the subgroups (single cone gutta-percha versus GuttaFusion®). However; Gutta-Fusion® showed highest bond strength value than single cone obturation technique. The coronal third slices of all groups showed highest value of bond strength in comparison to the middle thirds and apical thirds. In the meantime, the middle third slices showed bond strength higher than that of the apical thirds for all groups. Statistical analysis was performed by using two way ANOVA and LSD tests. Conclusions: The instrumentation techniques and the obturation materials significantly affected the push-out bond strength values of obturation system. The highest value was appointed in root canals instrumented with ProTaper Universal System; obturated with GuttaFusion® and BC sealer, whereas, the lowest bond strength was appeared at canals instrumented with ProTaper Next; obturated with single cone gutta-percha and BC sealer.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sat Sep 27 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of in office bleaching on surface roughness and micro-hardness of newly developed composite materials (In vitro study)
...Show More Authors

Background: Alterations in the microhardness and roughness are commonly used to analyze the possible negative effects of bleaching products on restorative materials. This in vitro study evaluated the effect of in-office bleaching (SDI pola office +) on the surface roughness and micro-hardness of four newly developed composite materials (Z350XT –nano-filled, Z250XT-nano-hybrid, Z250-mico-hybrid and Silorane-silorane based). Materials and methods: Eighty circular samples with A3 shading were prepared by using Teflon mold 2mm thickness and 10mm in diameter. 20 samples for each material, 10 samples for base line measurement (surface roughness by using portable profillometer, and micro-hardness by usingDigital Micro Vickers Hardness Test

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the

... Show More
Crossref (1)
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Study of R -molar ratio effect on the transformation of tetraethylorthosilicat precursor to gels in sol-gel technique
...Show More Authors

The effect of using different R -molar ratio under variable reaction conditions (acidic as well as basic environment and reaction temperature) have been studied. The overall experiments are driven with open and closed systems. The study shows that there is an optimum value for a minimum gelling time at R equal 2. The gelling time for all studied open system found to be shorter than in closed system. In acidic environment and when R value increased from 2 to 10, the gelling time of closed systems has increased four times than open systems at T=30 ?C and fourteen times when temperature reaction increased to 60 ?C. While in basic environment the influence of increasing R value was limited.

View Publication Preview PDF
Crossref
Publication Date
Sat Aug 22 2020
Journal Name
Multicultural Education
Effect Of Using Webinar Technique On The Digital Culture Of Chemistry Students In Ibin Haitham Pure Science College
...Show More Authors

The aim of this research is to identify the effect of Webinar technique on digital culture in the College of Education for pure sciences at Ibin Haitham, University of Baghdad. The research samples consisted of (68) male and female students from the Chemistry Department who are following classes during the (2019- 2020) academic year. The samples represent (42%) of the total number of (162) students split into control and experimental groups. For this purpose, the scientific contents for testing were determined. The experimental part is based on analysis of the results from experiments in (preliminary standard solutions, refractive index, Beer-Lambert law). To achieve the aim of the research in testing the measure of student's digital cultur

... Show More
Publication Date
Sun Jan 21 2024
Journal Name
Biomedicine
Detection of the effect of synthetic siRNA on efflux pump MexA gene expression and antibiotic resistance in clinical isolates of Pseudomonas aeruginosa
...Show More Authors

Introduction and Aim: Pseudomonas aeruginosa is a nosocomial infection with an ability to develop high levels of antibiotic resistance. The efflux pump system is one of the mechanisms that is linked to multidrug resistance in P. aeruginosa. In this study, we employed siRNA loaded on gold nanoparticles against the MexA efflux pump gene to decrease the MexA gene expression in P. aeruginosa and estimated antibiotic resistance after gene silencing.   Materials and Methods: This study examined four strains of P. aeruginosa isolated from patients in various hospitals in Baghdad. Bacteria isolated were identified by biochemical tests and Vitek compact 2 system.  Single-stranded siRNA (33bp) designed in this study was loaded onto gold

... Show More
View Publication
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
The Effect of Laser And Thermal Treatment on the Hardness and Adhesion Force on the Cermet Coating By Thermal Spray Technique
...Show More Authors

Ceramic coating compose from a ceramic mixture (MgO, Al2O3) and metall (Al-Ni) were produced by Thermal Spray Technique. The mixed ratio of used materials Al:Ni (50%) and 40% of Al2O3 and 10% MgO. This mixture was spray on a stainless steel substrate of type (316 L) by using thermal spray with flame method and at spraying distances (8, 12, 16 and 20) cm, then the prepared films were treated by laser and thermal treatment. After that performing a hardness and adhesion tests were eximined. The present study shows that the best value of the thermal treatment is 1000 ℃ for 30 mint; the optimum spray distance is 12 cm and most suitable laser is 500 mJ where the microscopic and mechanical character

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Sep 02 2017
Journal Name
International Journal Of Science And Research (ijsr)
Experimental Investigation on Rheological Characterization of ecovio® F Film C2203biopolymer Melts
...Show More Authors

Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
The Effect of Tool Path Strategy on Mechanical Properties of Brass (65-35) in Single Point Incremental Sheet Metal Forming (SPIF)
...Show More Authors

In this paper, three tool paths strategies; iso-planar, helical and adaptive have been implemented to investigates their effect on the mechanical properties of Brass 65-35 formed by single point incremental sheet metal forming process. To response this task, a fully digital integrated system from CAD modeling to finished part (CAD/CAM) for SPIF process has been developed in this paper.
The photo-micrographs shows an identical grain formation due to the plastic deformation of the incremental forming process, change in the grain shape and size was observed. It's found that the adaptive tool path play a significant role to increase the hardness of the formed specimen from (48 to 90 HV) and the grain texture of the formed specimen found a

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Communications In Mathematical Biology And Neuroscience
Chaos in the three-species Sokol-Howell food chain system with fear
...Show More Authors

View Publication
Scopus (13)
Crossref (1)
Scopus Clarivate Crossref