Purpose: To evaluate the effect of different surface treatments on shear bond strength between dentin and IPS e.max lithium disilicate glass-ceramic. Materials and Methods: Eighteen extracted third molars were embeded in epoxy resin. The tooth was sectioned vertically in mesiodistal direction using a low speed hard tissue microtome. The buccal and lingual surfaces of each section were ground flat using 600 grit Silicone carbide paper. Eighteen ceramic discs consisted of lithium disilicate glass-ceramic were prepared with a diameter of 4.7mm and height of 2.2mm. The discs were divided in two groups (n=10): (1) IPS e.max treated with hydrofluoric acid and Monobond Plus (MBP) and (2) IPS e.max treated with Monobond Etch &Prime (MBEP). The tooth was cemented with Multilink Automix and stored for 24hours at room temperature before thermocycling and subsequently loaded to failure in Universal Testing Machine. Failure mode were recorded for each specimen. Result: Bond strength analysis and t-test analysis MBEP demonstrated the higher shear bond strength (SBS). MBP and MBEP showed no statistically significant difference were found between them. One-way ANOVA and t-test was used to determine differences in bond strength within and between the groups. Cohesive failure in resin cement was predominant with higher results while adhesive and mixed with lower and equal. Conclusion: Surface treatment with Monobond Etch and Prime has a favorable effect on SBS between dentin and lithium disilicate glass-ceramic with resin cement compared with Monobond Plus.
EP/ metal composites were prepared as adhesives between two steel rods. Epoxy resin (EP) was used as a matrix with metal as fillers (Al, Cu, Fe,).
The preparation method for tensile adhesion tests includes two steel rods with adhesive composites between the rods to measure adhesion strength Sad and adhesion toughness Gad.
Results of tensile adhesion tests show that EP/ metals composite have maximum strength Sad for certain weight percentage of metals 2.95 and 9MPa at 10% for EP/Al and EP/Cu composite and 8.2MPa at 40% for EP/Fe composites
The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and
The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and
The research aims to identify the level of balance in the architectural thought influenced by the rational type human consciousness, the materialistic based on the Empirical type, moral based on human experience as source of knowledge.
This was reflected in architecture in the specialized thought that the mind is the source of knowledge which explains the phenomena of life. The rational approach based on objectivity and methodology in (Form Production), the other approach is based on subjectivity in form production (Form Inspiration).
The research problem is that there is imbalance in the relationship between the rational side and the human experience in architecture, which led into imbalance between theo
... Show MoreOne of the issues that occupied the doctrinal mind and differed the attention of scientists is the question of (the quality of the composition of God), so each team of scientists went the doctrine that led him to his evidence.
I wanted through this research to stand on the truth of the matter according to what I reached after looking at the views of the people and their evidence and direct the dispute between scientists.
It was presented with an introduction that was an introduction to the issue, where it began with the introduction of the definition of attributes, and then began to define the composition and view the views of scientists and evidence, and then concluded it with a conclusion mentioning what I have reached.
The metallicity [Fe/H] for several stars accompanied by Extra-solar planets were calculated and plotted as a function of stars mass (M*). Results showed that masses of Extra-solar planets stars are well correlated with their metallicity .This relation could be explained by the equation: Y=-0.0045x + 0.065. The metallicity limit is found to be in the range of (0.18 to 0.3), relative to the mass limit in the range of (0.76 to 1.44) MSun.
This criteria is a good tool that can be used by observers who are aiming for detecting Extra-solar planets
Background: The discriminative power of the classical WHO parameters in relation to male fertility is quite low, because they only address few aspects of sperm quality and function. This has led investigators to focus their attention on the male gamete and in particular its genome.Objective: To explore which of the sperm DNA damage parameters measured by comet assay are more reliable, and their relations with the standard semen parameters.Methods: Study was done on 40 infertile men selected from couples attending the Institute of Embryo Reasearch and Infertility Treatment at Al-Kadhimiya City/ Baghdad in the period between February 2009 and May 2009, with a history of infertility of ≥1 years; and 15 healthy volunteers of proven fertili
... Show More