Background: Oral lichen planus (OLP) is a chronic inflammatory disease with an autoimmune inflammatory pathogenesis. The purpose of this study was to evaluate the role of angiogenesis in the pathogenesis of OLP, using CD34 stain to highlight the blood vessels for measuring the microvessel density (MVD) as well as to evaluate the relation of this marker with the degree of inflammation Materials and Methods: Immunohistochemical (IHC) staining technique was used to evaluate angiogenesis using CD34 in 46 paraffin blocks 10 of them obtained from normal mucosa and 36 from cases diagnosed as lichen planus , 20 of them diagnosed as Reticular type while 16 as erosive type. Severity of inflammation was divided into mild, moderate and severe according to the number of mononuclear cell infiltrate. Results: The mean MVD as determined by the mean number of CD34 positive vessels in hot areas for OLP group was higher 39.2 (31.9 for reticular group & 48.375 for erosive group), whereas the mean MVD for control group 19.5 so that there was statistically significant difference between OLP group and the control group (p value<0.001). Regarding the severity of inflammation mean MVD was significantly increased as the degree of inflammation increased ( p value<0.001). Conclusion: Angiogenesis may be an integral component associated with the development of the OLP
Catalytic microwave-assisted pyrolysis of biomass is gaining popularity as an alternative to fossil fuels due to health, environmental, climate, and economic issues. This study conducted a catalytic pyrolysis process of the Albizia plant's branches using an Iraqi clay catalyst (bentonite) focusing on the variables including the biomass-particle size, experimental time, microwave power level, and the catalyst-to-biomass ratio. The physical and chemical properties of the resulting biofuel were analyzed presented by HHV, acidity, density, viscosity, GC-MS, FTIR for bio-oil and SEM, EDX, BET, HHV, FTIR for biochar. The study revealed that addition of bentonite as a catalyst led to enhanced production of biogas produced from 5% to 45% an
... Show MoreThe elastic transverse electron scattering form factors have been studied for the 11Li nucleus using the Two- Frequency Shell Model (TFSM) approach. The single-particle wave functions of harmonic-oscillator (HO) potential are used with two different oscillator parameters bcore and bhalo. According to this model, the core nucleons of 9Li nucleus are assumed to move in the model space of spsdpf. The outer halo (2-neutron) in 11Li is assumed to move in the pure 1p1/2, 1d5/2, 2s1/2 orbit. The shell model calculations are carried ou
... Show MoreA microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/mi
... Show MoreObjective: To evaluate the nurse's practices and it's relationship between with thier demographic characteristic.
Methodology: A descriptive study was carried out , from January 15th 2002 to April 15th 2002 , to evaluate the
nurse’s practices toward patients who undergo cardiac catheterization . A purposive sample of ( 65 ) nurse , was
selected out of three teaching hospitals in Baghdad city . These nurses were worked at the catheterization units
and catheterization labs .A questionnaire was constructed for the purpose of the study , which comprised of three
major parts in which there were ( 45 ) items . Reliability and validity of the questionnaire were determined
through the conduct of a pilot study .
Data were c
In this paper, 3D simulation of the global coronal magnetic field, which use observed line of sight component of the photosphere magnetic field from (MDI/SOHO) was carried out using potential field model. The obtained results, improved the theoretical models of the coronal magnetic field, which represent a suitable lower boundary conditions (Bx, By, Bz) at the base of the linear force-free and nonlinear force free models, provides a less computationally expensive method than other models. Generally, very high speed computer and special configuration is needed to solve such problem as well as the problem of viewing the streamline of the magnetic field. For high accuracy special mathematical treatment was adopted to solve the computation comp
... Show MoreThis paper is summarized with one of the applications of adsorption behavior; A UV-Vis method has been applied to survey the isotherm of adsorption. Results for experimental showed the applicability of Langmuir equation. The effect of temperature on the adsorption of cobalt (II) Complex by bentonite surface was studied. The results shown that the amount of adsorption was formed to increase, such as the temperature increase (Endothermic process). Cobalt (II) Complex has adsorption studies by bentonite surface at different pH values (1.6-10); these studies displayed an increase in adsorption with increasing pH. ∆G, ∆H, and ∆S thermodynamic functions of the cobalt (II) Complex for their adsorption have been calculated
Test results of six half-scale reinforced concrete flat plates connections with an opening in the vicinity of the column are reported. The test specimens represent a portion of a slab bounded by the lines of contraflexure around the column. The tests were designed to study the effect of openings on the punching shear behavior of the slab-column connections. The test parameters were the location and the size of the openings. One specimen had no opening and the remaining five had various arrangements of openings around the column. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The openings in the specimens were square, with the sides parallel to the sides of the column. Three sizes of ope
... Show More