Background: The Infraorbital foramen is an anatomical structure with an important location in the maxilla, position of foramen in maxillofacial area is necessary in clinical situation requiring regional nerve blocks that are performed in children undergoing facial surgeries to avoid injury to corresponding nerve. The aim of study was to determine the position of the Infraorbital foramen and to correlate Infraorbital foramen position with age and gender using computed tomography. Subjects, Materials, and Methods: The sample consist of prospective study for 50 Iraqi subjects (21 male and 29 female) with age ranged from (5-17) years. The examination was performed on Multi – Slice Spiral Tomography scanner in Al-Karakh General Hospital. Using sagittal and coronal sections including right and left sides and the following measurements were done: 1. The distance from crista galli to the midpoint of fusion of hard palate(Midline of the patient) in the coronal section. 2. The distance from mid line to the infraorbital foramen, in the coronal section for both sides right and left. 3. The distance from sella turcica to the infraorbital foramen, in sagittal section for both sides right and left. 4. The distance from nasion to the infraorbital foramen, in coronal section for both sides right and left. Results: The partial regression coefficient for each year increase in age the linear measurements (midline-infraorbital foramen) (nasion-infraorbital foramen) and (vertical distance from nasion meeting the horizontal line from infraorbital foramen to midline) are expected to significantly increase after adjusting for confounding effect of gender. From multiple linear regression model designed in this study two mathematical formulae were derived for correlation of infraorbital foramen position with the age and gender:- Y1 [Linear measurement (Midline-Infraorbital foramen) mm] = 19.56 + (1.02 x gender) + (0.53x age in years). Y2 [Linear measurement (vertical distance from nasion meeting the horizontal line from Infraorbital foramen to midline)] = 28.42 + (2.5 x gender) + (0.30 x age in years). Conclusions: Computed tomography scan information facilitates the localization of infraorbital foramen position for successful access of the needle in infraorbital nerve block in children of different age and gender.
The present study was carried to evaluate antibacterial activity of Acetone, Alcholic (cold and hot) and Aqueaus(water) extracts of Citrus aurantifoliaseeds,against growth of some bacteria isolated from burns infections(Pseudomonas aeruginosa,Escherichia coli, Klebsiellapneumonia,Staphylococcusaureus)fromKindy HospitalIn Baghdad from March to June 2012.Antibiotic Sensitivity was done for all isolated bacteria used in this study.Results showed variation in antibacterial activity of different extracts against all tested bacteria by well diffusion technique in agar and measuring the diameter of inhibition zone, at concentration 250Mg-ml. Acetone extract had the greatest inhibitory effect followed by hot alcoholci extract, and then cold alcohol
... Show MoreObjective: To evaluate the effectiveness of educational program on female students’ knowledge toward premenstrual syndrome.
Methodology: A quasi-experimental design study conducing on (140) student purposely in four secondary schools at Al-sadder city (70) student for study group and (70) for control group. The prevalence of PMS selected through American College of Obstetricians and Gynecologists (ACOG) (2015) criterias to select PMS students before program. The education program were set in four steps, the first step (pre-test) is to assess the knowledge , before the implementation of the program, the second step is implementing the program, following two steps post-test I and II between each test two weeks. Validity is determined
In the current work, the mixing ratios ( 𝛿 ) of gamma transitions were calculated from energy levels in the isotopes neodymium 60𝑁𝑎 142−150 populated in the 60Nd 142− 150 (n, n ˊγ) 60Nd 142− 150 using the 𝑎2 ratio method. We used the experimental coefficient (𝑎2 ) for two γ-transitions from the initial state itself, the statistical tensor 𝜌2(𝐽𝑖), associated with factor 𝑎2 , would be the same for the two transitions. The results obtained are in good agreement or within the experimental error with -those previously published. And existing contradictions resulting from inaccuracies in the empirical results of previous work. The current results confirm that the , 𝑎2 − method is used to calculate th
... Show MoreThe widespread use of the Internet of things (IoT) in different aspects of an individual’s life like banking, wireless intelligent devices and smartphones has led to new security and performance challenges under restricted resources. The Elliptic Curve Digital Signature Algorithm (ECDSA) is the most suitable choice for the environments due to the smaller size of the encryption key and changeable security related parameters. However, major performance metrics such as area, power, latency and throughput are still customisable and based on the design requirements of the device.
The present paper puts forward an enhancement for the throughput performance metric by p
... Show MoreKE Sharquie, AA Al-Nuaimy, WJ Kadhum, Saudi medical journal, 2006 - Cited by 3
The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the
... Show Morea laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn
... Show MoreThe ability of beans (Phaseolus vulgaris L.) to uptake three pharmaceuticals (diclofenac, mefenamic acid and metronidazole) from two types of soil (clay and sandy soil) was investigated in this study to explore the human exposure to these pharmaceuticals via the consumption of beans. A pot experiment was conducted with beans plants which were grown in two types of soil for six weeks under controlled conditions. During the experiment period, the soil pore water was collected weekly and the concentrations of the test compounds in soil pore water as well as in plant organs (roots, stems and leaves) were weekly determined.
The results showed that the studied pharmaceuticals were detected in all plant tissues; their concentration
NH3 gas sensor was fabricated based on deposited of Functionalized Multi-Walled Carbon Nanotubes (MWCNTs-OH) suspension on filter paper substrates using suspension filtration method. The structural, morphological and optical properties of the MWCNTs film were characterized by XRD, AFM and FTIR techniques. XRD measurement confirmed that the structure of MWCNTs is not affected by the preparation method. The AFM images reflected highly ordered network in the form of a mat. The functional groups and types of bonding have appeared in the FTIR spectra. The fingerprint (C-C stretch) of MWCNTs appears in 1365 cm-1, and the backbone of CNTs observed at 1645 cm-1. A homemade sensi
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show More