Preferred Language
Articles
/
jbcd-1858
A Comparison of Vertical Marginal Fit of different Brands of Translucent Zirconia Crown Restorations
...Show More Authors

Background: As the development of zirconia crown using CAD/CAM technology, the usage of full zirconia crown is gradually increased. The aim of this in-vitro study was to evaluate and contrast the vertical marginal fit of single all-ceramic translucent zirconia crowns constructed from different brands translucent zirconia blanks. Materials and Methods: An acrylic resin model of a left maxillary premolar was prepared all around the tooth with (1 mm) depth and 3D scanning to get fifteen STL files, then distributed into three groups (Imes-icor, Whitepeaks and Dental direct), 3D scanning and milling machine by Imes-icor CAD/CAM devise. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) using a light microscope at a magnification of x100. One-way ANOVA, LSD tests were performed to determine the mean and standard deviation of the three blanks groups. Results: Statistically high significant difference (p < 0.00) was found between the groups. The marginal gap value of the groups varied Whitepeaks crowns was (105.42 ± 7) μm, which was significantly higher than the two overall mean marginal gap measured for the Imes-icor crowns (59.3 ± 4) μm and Dental direct crowns (54.5 ± 4.9) μm, the Dental direct which was lowers overall mean vertical gap measurement. Conclusions: The marginal gap values of Dental direct crowns is considerably lower than that of Whitepeaks crown, The marginal gap values of all the groups made of monolithic high translucent Y-TZP demonstrated acceptable marginal gaps values.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 07 2020
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect of Vertical Irregularity in Multi-Storied Building under Seismic Loading
...Show More Authors

Publication Date
Wed Jul 01 2020
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect of Vertical Irregularity in Multi-Storied Building under Seismic Loading
...Show More Authors

Publication Date
Sat Sep 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Enhancing the Lifting Capacity of Drilling Fluids in Vertical Oil Wells
...Show More Authors

Of the many functions that are performed by the drilling fluid, the most important is to transport cuttings from the bit up the annulus to the surface. Various drilling fluid have been widely used in the oil industry to improve lifting capacity. In this study, three mud type have been used which they are, oil base mud, X-anthan polymer and a mixture of CMC and bentonite ,by using Carrying Capacity Index  calculation (CCI) , the Xanthan  gave good values of CCI than other studied drilling fluid. By using Sifferman chart and field data from well in south of Iraq and API equation to find cutting concentration in the annulus, The results showed that the used of thick mud increase the lifting capacity and decrease volumetric drill c

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The relation between the mesio-distal crown widths of the deciduous second molars and the permanent first molars
...Show More Authors

Background: This study aimed to find whether there is a relation between the mesio-distal crown diameters of the deciduous second molars and the permanent first molars in an Iraqi sample from Baghdad city. Material and methods: The sample consisted of 54 Iraqi children aged 8-9 years at the mixed dentition stage. The measurements included the mesio-distal crown width of the deciduous second molars and the permanent first molars on the study casts using digital sliding vernier. Results: The results revealed absence of the side difference of the widths of teeth measured. High significant gender difference was detected for the permanent first molars and the deciduous second molars except mandibular permanent first molar. On the other hand, hig

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Mesio-distal crown dimension of permanent dentition in normal, crowding, and spacing of young adult sample aged 18-25 years
...Show More Authors

Background: This study aimed to assess the effect of tooth width in malocclusion in relation to normal, crowding, and spacing dentition. Materials and methods: The sample included dental casts of some dental students and orthodontic patients; their age was (18-25) years and having three groups normal, crowding, and spacing dentition groups. The sample was equally divided to three groups normal, crowding, and spacing dentition groups, each group contained 50 maxillary and 50 mandibular casts that were further subdivided by gender; all the stone casts were measured by highly sensitive digital vernier. Results and Conclusions: Non-significant side difference was found in both dental arches in the three studied groups. Males had higher mesiodis

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 03 2012
Journal Name
International Urology And Nephrology
GFR estimation in the morbidly obese pre- and postbariatric surgery: one size does not fit all
...Show More Authors

View Publication
Scopus (18)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Engineering And Technology Journal
Comparison between the Biological Activity of Agaricus bisporus Fruiting Bodies and Albizzia lebbeck Leaves Extract against Different Pathogenic Microoganisms
...Show More Authors

View Publication
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Saudi Endodontic Journal
Comparison of root canal transportation and centering after instrumentation through conservative and traditional access cavities using different file systems
...Show More Authors
Introduction:

While conservative access preparations could increase fracture resistance of endodontically treated teeth, it may influence the shape of the prepared root canal. The aim of this study was to compare the prepared canal transportation and centering ability after continuous rotation or reciprocation instrumentation in teeth accessed through traditional or conservative endodontic cavities by using cone-beam computed tomography (CBCT).

Materials and Methods:

Forty extracted intact, matured, and 2-rooted human maxillary first premolars were selected for this

... Show More
View Publication
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Dissolution of inorganic phosphorous ion from human enamel treated with different concentration of Siwak aqueous extract in comparison with sodium fluoride
...Show More Authors

Background: The use of Miswak, chewing sticks (salvadorapersica) can be traced back to Babylonians some 7000 years ago. It is commonly used throughout the world especially for the purpose of oral hygiene. Muslims are using as the religious view. Current study aimed to test the ability of aqueous siwak extract to increase the resistance of enamel surface against acid dissolution compared to sodium fluoride. Materials and Method: Twenty maxillary first premolars were treated with the selected solutions included two aqueous siwak extract concentration(5%,10%) and sodium fluoride(0.05%)as control positive for 2 minutes once daily for 20days interval, de ionized water was used as control negative. The concentration of the dissolved phosphorus i

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Shear Bond Strength of Sapphire Bracket Bonded to Zirconium Surface after Using Different Surface Conditioning Methods (In Vitro Study)
...Show More Authors

Background: The present study was carried out to compare shear bond strength of sapphire bracket bonded to zirconium surface after using different methods of surface conditioning and assessment of the adhesive remnant index. Materials and methods: The sample composed of 40 zirconium specimens divided into four groups; the first group was the control, the second group was conditioned by sandblast with aluminum oxide particle 50 μm, the third and fourth group was treated by (Nd: YAG) laser (1064nm)(0.888 Watt for 5 seconds) for the 1st laser group and (0.444 Watt for 10 seconds) for the 2nd laser group. All samples were coated by z-prime plus primer. A central incisor sapphire bracket was bonded to all samples with light cure adhesive res

... Show More
View Publication Preview PDF
Crossref (1)
Crossref