Preferred Language
Articles
/
jbcd-1857
Fracture Resistance of Endodontically Treated Premolar Teeth with Extensive MOD Cavities Restored with Different Bulk Fill Composite Restorations (An In vitro Study)
...Show More Authors

Background: The present in-vitro study was undertaken to evaluate and compare fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different bulk fill composite restorations (EverX posterior, Alert, Tetric EvoCeram Bulk Fill, and SDR). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Forty-eight human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into six groups of eight teeth each (n=8): (Group 1) intact control group, (Group 2) unrestored teeth with endodontic treatment, (Group 3) restored with (TetricEvoCeram Bulk Fill), (Group 4) restored with SDR bulk-fill flowable composite, (Group 5) restored with EverX Posterior composite and (Group 6) restored with Alert composite. . All specimens were subjected to compressive axial loading until fracture in a universal testing machine. The data were statistically analyzed using one-way ANOVA test and LSD test. Macroscopic fracture type were observed and classified into favorable and unfavorable. Specimens in groups 3, 4, 5 and 6 were examined by stereomicroscope at a magnification of 20× to evaluate the mode of failure into adhesive, cohesive or mixed. Results: The mean fracture load was (1.2505Kn) for group 1, (0.371Kn) for group 2, (0.512 Kn) for group 3, (0.6435 Kn) for group 4, (0.608 Kn) for group 5, and (0.8315) for group 6. Using one way ANOVA test a highly significant difference (P < 0.01) were found among all groups. The use of Alert composite (which contain micro glass fiber) improved the fracture resistance significantly in comparison to other groups. SDR bulk-fill flowable composite showed better improvement in fracture resistance but with no significant differences in comparison to EverX composite restoration (which contain Short E-glass fiber filler). The type of failure was unfavorable for all the restored groups. Conclusion: All experimental composite restorations showed significant improvement in the resistance to cuspal fracture in comparison to unrestored one (group 2). However, under the conditions of this study, direct composite restorations should be considered as a valid interim restoration for weakened endodontically treated teeth before cuspal coverage can be provided.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Studying Biomimetic Coated Niobium as an Alternative Dental Implant Material to Titanium (in vitro and in vivo study)
...Show More Authors

Commercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concent

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Investigation in vitro the effect of X-rays, gamma rays and beta particles on the physical and structural characteristics of human teeth
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Mesenchymal and stemness transdifferentiation via in-vitro infection of T24 cell line with Klebsiella pneumoniae
...Show More Authors

Klebsiella pneumoniae has been found in the urinary tract of some bladder cancer patients. Bacterial presence within tumor tissue may affect the tumor-microenvironment and consequently influence cancer behavior, development, and treatment response. This study investigated mesenchymal and stemness transdifferentiation of bladder cancer cell line due to environmental stress of K. pneumoniae. Cultures of urothelial bladder cancer cell line (T24) were infected with K. pneumoniae with different multiplicity of infection (MOI) for two and four days. Transdifferentiation-associated features were morphologically assessed.

Moreover, transdifferentiation markers were estimated using Q-PCR and immunohistoc

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Research Journal Of Pharmacy And Technology
Corrosion behavior of implant coated with different biocompatible material
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Charge Transfer studies of some oxadiazole derivatives with different
...Show More Authors

the physical paraneters of oxadizole derivaties as donor molecules have been measured the charge transfer and methanol as solvent have been estimated from the electonic spectra

View Publication Preview PDF
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Studying the Effect of Different Separating Medium on the Roughness of the tissue surface of Acrylic Denture Base (In Vitro Study)
...Show More Authors

Objective: In order to evaluate the effect of different typed of Separating Medium on the roughness of the fitted
tissue surface of acrylic denture base.
Methodology: Chosen three types of separating medium (Group A Tin foil), (Group B Detery Isolant),(Group C
Cold Mould Seal),used 30 samples of hot cure acrylic resin ,10 samples for each group, after complete curing of
these samples , Profilometer device was used to measure the surface roughness of each sample in all groups.
Results: Using One Way ANOVA Test and LSD test, the results were highly significant in differences among all
groups. Although (Group A) showing lest roughness, (Group B) showing a satisfactory result of roughness, While
(Group C) Showing the hig

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2007
Journal Name
Al-nahrain Journal Of Science
Delayed type of hypersensitivity and its relation with experimental infection with two different Leishmania antigen
...Show More Authors

ز

Publication Date
Sun Sep 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Bulk heterojunction blend (NiPcTs:PEDOT:PSS) in gas sensing
...Show More Authors

Thin films of bulk heterojunction blend Ni-Phthalocyanine
Tetrasulfonic acid tetrasodium salt and dpoly
(3, 4-ethylenedioxythiophene) poly (styrenesulfonate) (NiPcTs:
PEDOT: PSS) with different (PEDOT:PSS) concentrations (0.5, 1, 2)
are prepared using spin coating technique with thickness 100 nm on
glass and Si substrate. The X-Ray diffraction pattern of NiPcTs
powder was studied and compared with NiPc powder, the pattern
showed that the structure is a polycrystalline with monoclinic phase.
XRD analysis of as-deposited (NiPcTs/PEDOT:PSS) thin films
blends in dicated that the film appeared at(100), (102) in
concentrations (0.5, 1) and (100) in concentration (2). The grain size
is increased with increasing

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparative Study between Different Oil Production Enhancement Scenarios in an Iraqi Tight Oil Reservoir
...Show More Authors

This paper presents a comparative study between different oil production enhancement scenarios in the Saadi tight oil reservoir located in the Halfaya Iraqi oil field. The reservoir exhibits poor petrophysical characteristics, including medium pore size, low permeability (reaching zero in some areas), and high porosity of up to 25%. Previous stimulation techniques such as acid fracturing and matrix acidizing have yielded low oil production in this reservoir. Therefore, the feasibility of hydraulic fracturing stimulation and/or horizontal well drilling scenarios was assessed to increase the production rate. While horizontal drilling and hydraulic fracturing can improve well performance, they come with high costs, often accounting for up t

... Show More
View Publication Preview PDF
Crossref