Preferred Language
Articles
/
jbcd-1855
The Effect of Different Light Cure Systems on Microhardness of Bulk Fill Composite Materials
...Show More Authors

Background: The aim of this study was to evaluate the effect of three types of light curing devices QTH, LED and Flashmax on the surface microhardness of three types of bulkfill composite resins; Filtek Bulkfill posterior composite ( 3M), Tetric Evo Ceram ( Ivoclar Vivadent) and Sonicfill composite ( Kerr) Materials and methods: Total number of 90 samples was prepared, 30 samples for each type of bulkfill composite, were divided into three main groups, group A: Filtek posterior bulkfil (3M), group B: Tetric Evo Ceram (Ivoclar Vivadent) and group C: contain Sonicfill composite (kerr). Which then divided into three subgroups (n= 10) (1) Samples cured by QTH system (2) Samples cured by LED system and (3) samples cured by Flashmax system then all samples were subjected for microhardness test (by Vickers hardness tester). The data were recorded and statistically analyzed, by the ANOVA and the Tukey test. Results: the data was subjected to statistical analysis using one way ANOVA and Tukey test, the result revealed that there was a high significant difference among the tested units with LED had high VHN values followed by QTH while Flashmax had lowest VHN values, also there was high significant difference among the tested materials in which Sonicfill composite had higher VHN value followed by Tetric EvoCeram while Filtek bulkfill posterior composite had the lowest VHN. Conclusions: microhardness of the composite resin materials depend upon energy of the curing device, time of exposure, composition of the composite material.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation the Effect of Alcohol Presence in Mouth Washes on Force Degradation of Different Configurations of Elastomeric Chains
...Show More Authors

Background: Elastomeric chains are one of the most commonly used force delivery systems. They have the ability to exert a continuous force, convenience of use, compatibility to oral environment and cost effectiveness but one of the inherited disadvantages is force degradation. Materials and methods: This in vitro study was designed to evaluate the effect of alcohol presence in mouthwashes on force decay of different configurations of clear elastomeric chains from (Ortho Technology company) which are: closed , short and long under the effect of time at (Initial, 1, 2, 3 and 4 weeks) intervals with exposure to different chemical solutions. A total (540) modules of elastomeric chains of three different types (long, short and closed) trans

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation the Effect of Addition of Plasma Treated Polypropylene Fiber and Silanized Silicon Dioxide Nanoparticles Composite on Some Properties of Heat-Polymerized Polymethylmethacrylate
...Show More Authors


Background: Polymethylmethacrylate (PMMA) is the most ‎commonly used m‏aterial in denture construction. This material is ‎far from ideal in fulfilling the‎ mechanical requirements, like low impact and transverse strength and poor thermal conductivity are present in this material. The purpose of this study was to study the effect of addition a composite which include 1%wt silanized silicone dioxide nano fillers (SiO2) and 1wt% oxygen plasma treated polypropylene fiber (PP) on some properties of heat cured acrylic resin denture base material (PMMA). Materials and methods: One hund‏red (100) prepared specimens were divided into five groups according to the tests, each group consisted of 20 specimens and t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Jun 30 2011
Journal Name
J Bagh College Dentistry
Comparison of the effect of stannous fluoride and sodium fluoride on surface roughness of Silorane and methacrylate based restorative material using light polarizing microscope
...Show More Authors

Background: The high reactivity of hydrogen peroxide used in bleaching agents have raised important questions on their potential adverse effects on physical properties of restorative materials. The purpose of this in vitro study was to evaluate the effect of in-office bleaching agents on the microhardness of a new Silorane-based restorative material in comparison to methacrylate-based restorative material. Materials and method: Forty specimens of Filtek™ P90 (3M ESPE,USA) and Filtek™ Supreme XT (3M ESPE, USA) of (8mm diameter and 3m height) were prepared. All specimens were polished with Sof-Lex disks (3M ESPE, USA). All samples were rinsed and stored in incubator 37˚C for 24 hours in DDW. Ten sample of each material were subjected to

... Show More
Publication Date
Sun Jun 02 2019
Journal Name
International Journal Of Drug Delivery Technology
Kinetic-spectrophotometric estimation of tetracycline in bulk and pharmaceutical forms
...Show More Authors

Simple and sensitive spectrophotometric method is described based on the coupling reaction of tetracycline hydrochloride (TC. HCl) with diazotized 4-aminopyridine in bulk and pharmaceutical forms. Colored azo dye formed during this reaction is measured at 433 nm as a function of time. Factors affecting the reaction yield were studied and the conditions were optimized. The kinetic study involves initial rate and fixed time (10 minutes) procedures for constructing the calibration graphs to determine the concentration of (TC. HCl). The graphs were linear for both methods in concentration range of 10.0 to 100.0 μg.mL-1. The recommended procedure was applied successfully in the determination of (TC. HCl) in its commercial formulations.

Scopus (3)
Scopus
Publication Date
Tue Aug 20 2019
Journal Name
International Journal Of Drug Delivery Technology
Kinetic - Spectrophotometric Estimation of Tetracycline in Bulk and Pharmaceutical Forms
...Show More Authors

Simple and sensitive spectrophotometric method is described based on the coupling reaction of tetracycline hydrochloride(TC. HCl) with diazotized 4-aminopyridine in bulk and pharmaceutical forms. Colored azo dye formed during this reaction is measured at 433 nm as a function of time. Factors affecting the reaction yield were studied and the conditions were optimized. The kinetic study involves initial rate and fixed time (10 minutes) procedures for constructing the calibration graphs to determine the concentration of (TC. HCl). The graphs were linear for both methods in concentration range of 10.0 to 100.0 µg.mL-1. The recommended procedure was applied successfully in the determination of (TC. HCl) in itscommercial formulations.

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Wed Aug 18 2021
Journal Name
Palarch’s Journal Of Archaeology Of Egypt/egyptology
THE EFFECT OF LOCAL FINANCING UPON REALIZING THE FINANCIAL INDEPENDENCE OF LOCAL UNITS IN DECENTRALIZED ADMINISTRATIVE SYSTEMS
...Show More Authors

The increasing level of residents’ requirements of the local community led to the necessity for sufficient local funding to satisfy the residents’ requirements and services of the local units affiliated with the decentralized administrative systems on the one hand, and to the role of local financing in the financial independence of local units on the other hand.With the presence of local financing, the financial independence of local units is achieved and is considered one of the conditions for financial independence, which is the provision of local financing to the units away from central support. The study focused in this research to clarify the concept of local financing for local units with a statement of its conditions and importan

... Show More
Publication Date
Fri Sep 15 2023
Journal Name
Bionatura
Effect of adding different levels of reishi mushroom (Ganoderma lucidum ) to broiler diets and its effect on productive performance
...Show More Authors

This study was conducted in the poultry fields of the College of Agricultural Engineering Sciences / University of Baghdad from 10/15/2021 to 11/25/2021.To know the effect of adding different levels of Ganoderma lucidum to broiler diets on productive performance. 200 unsexed (Ross 308) chicks of one day age with a starting weight of (40) g were used. The chicks were randomly distributed into four treatments and 50 birds. One treatment included five replicates (10 birds/replicate), and the experimental treatments was as follows: T1, T2, T3, T4, and the percentages of adding reishi mushroom were 0, 0.5, 1, and 1.5 g/kg of feed, respectively, and the birds were fed on three starter diets, growth and final diets, The results of this stu

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jan 24 2025
Journal Name
Plos One
Assessment of the bypass of obturation materials beyond fractured instruments after using different obturation techniques in simulated curved canals (An in-vitro study)
...Show More Authors

This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.5 mm, prepared to an ISO #15 diameter and taper. Canals were shaped using ProTaper Universal files (Dentsply Maillefer) attached to an X-smart Plus endo motor (Dentsply), set at 3.5 Ncm torque and 250 rpm, up to size S2 at working length. To simulate fractures, F2 and F3 files were weakened 3 mm from the tip, then twisted to break in the apical and middle sections of the canal, re

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Fri Jan 17 2025
Journal Name
African Journal Of Biomedical Research
Digital Evaluation of Cuspal Deflection of Endodontically Treated Teeth Restored with Resin Composite and Different Fiber Formulations
...Show More Authors

Background: This study evaluated the influence of different fiber formulations incorporation in resin composite on cuspal deflection (CD) of endodontically-treated teeth with mesio-occluso-distal (MOD) cavities. Materials and Methods: Thirty-two freshly extracted maxillary premolar teeth received MOD cavity preparation followed by endodontic treatment using single cone obturation technique, and divided into: Group I: direct composite resin only using a centripetal technique, Group II: direct composite resin with short fiber-reinforced composite (everX Flow), Group III: direct composite resin with leno wave ultra-high molecular weight polyethylene (LWUHMWPE) fibers placed on the cavity floor, and Group IV: direct composite resin with LWUHMWP

... Show More
Preview PDF
Publication Date
Wed Nov 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF