Preferred Language
Articles
/
jbcd-1854
Marginal Discrepancy and Fracture Resistance of CAD/CAM Ceramill Sintron Metal Copings with Different Porcelain Materials
...Show More Authors

Background: This study was performed to compare the marginal fit changes and facture resistance of metal ceramic crowns constructed from Ceramill Sintron metal coping veneered with three different porcelain veneering materials (Vita Master Koromikos VMK, Willi Geller Creation CC and GC initial MC), also to evaluate the influence of thermocycling on load at fracture. Materials and Methods: Master brass die was scanned ,then metal coping was designed and milled from Ceramill Sintron blank to get 60 metal copings, then divided randomly into three groups(20 sample), then veneered with porcelain: VITA, Creation or GC. The marginal gaps were measured before and after porcelain veneering then marginal fit changes was calculated. Fracture resistance test was done by Instron®, the master die was duplicated to sixty analogs then each analog was fixed into acrylic base. After that each crown was cemented onto the corresponding die analog. Ten samples of each group were subjected to compressive loading to fracture and other ten subjected to thermocycling followed by compressive loading to fracture. Result and Conclusion: The result of marginal fit changes showed that GC group had the lowest marginal gap follow by VITA and Creation. While VITA group showed the highest fracture resistance follows by GC then Creation. Thermocycling process did not significantly reduce the load at fracture for all groups.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Internal Fixation And Bone Grafting Of Non-Union Humeral Diaphyseal Fracture
...Show More Authors

Background: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union w

... Show More
View Publication Preview PDF
Publication Date
Thu May 14 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Clinical Dentistry Preview Publication Details
The effect of surgical approaches on the stability and marginal bone loss of early loaded slactive implants with screw retention mean: Comparative clinical and radiological prospective study
...Show More Authors

Purpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app

... Show More
View Publication Preview PDF
Scopus
Publication Date
Thu May 14 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the push-out bond strength of root canal obturation materials filled by four different obturation techniques
...Show More Authors

Background: The aim of this study was to comparatively evaluate the push out bond strength (PBS) of root canal fillings using four different obturation techniques (single cone (SC), cold lateral compaction (CLC), continuous wave (CW), and carrier based gutta percha (CBG)). Materials and Methods: Forty mandibular premolar decoronated and instrumented with rotary ProTaper to F3 then teeth were divided randomly into 4 groups of 10 teeth for each as follow: group (I) single- cone obturation with matched-taper gutta-percha, group (II) cold lateral compaction technique, group (III) continuous wave of obturation technique, and group( IV) carrier based gutta-percha technique. Zinc oxide eugenol (ZOE) sealer was used as a root canal sealer for the

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 15 2019
Journal Name
Research Journal Of Pharmaceutical, Biological And Chemical Sciences
Synthesis, Spectroscopic, Characterization and Biological Activities of Schiff Base Ligand and Metal Complexes of Some Metal (II) Salts with Anthranilic Acid
...Show More Authors

Schiff base N,N'-Bis-(4-dimethylamino-benzylidene)-benzene-1,4-diamine has been synthesized from 4-dimethylaminobenzenaldehyde and benzene-1,4-diamine. The structure of Schiff base was obtained by (C.H.N.) microanalysis, Mass, 1HNMR, FT-IR and UV-Vis spectral methods and thermal analysis. Metal mixed ligand complexes of some metal(II) salts with Schiff base ligand and anthranilic acid were prepared in the molar ratio (1:2:2), (Metal):(SBL)2:(Anthra)2, (SBL)= Schiff base ligand, (Anthra) =anthranilic acid and Metal= Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II). The thermal behaviour (TGA) of the complexes was studied. The prepared complexes identified by using mass, thermal analysis, FT.IR and UV-Vis spectrum methods, on otherwise flame

... Show More
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prediction of Fracture Pressure Gradient in Halfaya Oilfield
...Show More Authors

   Fracture pressure gradient prediction is complementary in well design and it is must be considered in selecting the safe mud weight, cement design, and determine the optimal casing seat to minimize the common drilling problems. The exact fracture pressure gradient value obtained from tests on the well while drilling such as leak-off test, formation integrity test, cement squeeze ... etc.; however, to minimize the total cost of drilling, there are several methods could be used to calculate fracture pressure gradient classified into two groups: the first one depend on Poisson’s ratio of the rocks and the second is fully empirical methods. In this research, the methods selected are Huubert and willis, Cesaroni I, Cesaroni II,

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Dec 01 2025
Journal Name
Egyptian Journal Of Microbiology
Role Of Preoperative Prophylaxis Antibiotics In Fracture Mandible
...Show More Authors

View Publication
Crossref
Publication Date
Wed Jan 16 2013
Journal Name
No Journal
Synthesis and Characterisation of Metal Complexes with Mixed Azido-Carboxylato Bridges
...Show More Authors

The research on coordination polymers chemistry based on organic-metal framework with bridging ligands has accelerated during the past two decades. It is an interested hot topic in the synthetic inorganic chemistry, which allowed the fabrication of a variety of interested materials. These materials have shown a range of applications including light harvesting and magnetic properties. The thesis is divided in three chapters. The first chapter gives a general introduction on the development of self-assembled polymeric species based on transition metal. It is also covered a summary of the literature review on the current state of the art on self-assembled coordination ploymers. Furthermore, it includes a description on various relevant topics

... Show More
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of etchant type and the use of silane on the shear bond strength of composite resin to porcelain
...Show More Authors

Background: This study was formulated to compare the effect of 5%hydrofluoric acid in comparison to 37%phosphoric acid with and without the application of silane on bond strength of composite to porcelain. Materials and Methods: Specimen preparation was divided in to two phases, metal-disks fabrication (8mm-diameter and 4mm-thickness) and ceramic veneering. Thirty two specimens were prepared, sandblasted with 50 μm aluminum oxide, and divided into four groups of eight samples. Groups I and III were etched with 37%phosphoric acid while groups II and IV were etched with 5%hydrofluoric acid; and groups I and II were silaneted while groups III and IV were not. Heliobond, and resin composite were applied to each specimen using a plastic transpa

... Show More
Preview PDF
Publication Date
Thu Jan 30 2014
Journal Name
Al-kindy College Medical Journal
THE PREVALENCE AND ANTIMICROBIAL RESISTANCE OF PSEUDOMONAS SPECIES IN PATIENTS WITH CHRONIC SUPPURATIVE OTITIS MEDIA
...Show More Authors

Background: Chronic suppurative otitis media (CSOM) is the result of aninitial episode of acute otitis media and is characterized by a persistent discharge from the middle ear through a tympanic perforation for at least 2 weeks duration. It is an important cause of preventable hearing loss, particularly in the developing world.Methods. 1. To get an overview on the bacterial ear infection profile in general 2. To assess the antibiotic resistance of Pseudomonal infection (PS) particularly since it is usually the commonest infection to cause otitis media and the most difficult to treat due to the problem of multi drug resistance... A cross sectional study was done which included 405 patient of CSOM patients196 (48%) case were males ,209 (52

... Show More
View Publication Preview PDF