ABSTRACT Background:- White spot lesions are common esthetic problem that compromise the success of orthodontic treatment. This study aimed to assess white spot lesions in patients with fixed orthodontic appliance at different time intervals. Materials & Methods:- Thirty two patients (24 females and 8 males) were included in this study and they underwent clinical examination for white spot lesions using enamel decalcification index at four time intervals: (2-3 weeks after appliance insertion, 2, 4 and 6 months). Results:- The patients were free of white spot lesions at the appliance insertion visit. The mean of white spot lesions was 2.22 which were increased significantly during six months to reach 24.59 at the end of study. There was a significant difference between the maxillary and the mandibular arches, however, there was no significant difference found between the right and the left sides in both arches. The total numbers of teeth affected by white spot lesions were 74.61% after six months of treatment. Maxillary second premolar and mandibular canine were the most affected teeth; whereas the gingival area around the orthodontic brackets was the most affected area. Conclusion:-Orthodontic patients had a high risk for development of white spot lesions.
Background: Separation and deboning of artificial teeth from denture bases present a major clinical and labortory problem which affect both the patient and the dentist. The optimal bond strength of artificial teeth with denture base reinforced with nanofillers and flexible denture bases and the effect of thermo cycling should be evaluated. This study was conducted to evaluate and compare the shear bond strength of artificial teeth (acrylic and porcelain) with denture bases reinforced by 5% Zirconium oxide nanofillers and flexible bases under the effect of different surface treatments and thermo cycling and comparing the results with conventional water bath cured denture bases. Material and methods: Two types of artificial teeth; acrylic and
... Show MoreCarnitine is a regulatory amino acid, necessary for the metabolism of long-chain fatty acids in the ß - oxidation, and it is important in the organization of the work of the blood brain barrier, and is very important in the treatment of infertility and sexual apathy. This study was conducted at the Poultry Farm of the Department of Animal Resource, College of Agriculture, University of Baghdad during the period from 15/2/2011 to 1/8/2011. The aim of this study was to investigate the effect of dietary supplementation with different levels of L - carnitin e on semen characteristics of guinea fowl male. A total of 24 guinea fowl male, 30 weeks of old were used in this study. Birds were randomly distributed into 4 groups (C0, C100, C200, C300)
... Show MoreAphelenchus avenae was isolated from the wheat crown in Summel distract- Duhok, Kurdistan region-Iraq infected by a crown rot disease which is caused by Fusarium spp; wheat's crown culturing on Potato Dextrose Agar (PDA) and incubating at 25°C A. avenae was found associated with fungal culture which meant that fungal nematode was parasitic on crown rot fungi on wheat crown, this species was described for the first time in Iraq.
Fungal Nematode incubated with Fusarium graminearum, F. oxysporum and Verticillium dahliae reproduce in both solid and liquid media, best results of nematode reproduction were recorded on F. graminearum followed by F. oxy
... Show MoreOne of the most important problems in tablet process is to control the flow of the catalyst through the hopper; Controlling the flow can be done either by changing the size of particles or added the different lubricant (stearic acid, starch, graphite) or blending of different lubricants. The study showed that we can control (increase or decrease) on the flow of the catalyst through the hopper by blending different lubricants for the constant percentage. The flow increasing when particles size (0.6 mm) and then decrease with or without lubricants, no effect on flow when particles size lower than (0.2 mm) with use that lubricants, and good flow on (0.4 mm) when use stearic acid and starch.
Background: The final stage of endodontic therapy is complete obturation of the root canal system to provide as perfect as possible at the cementodentinal junction of the apical foramen. The purpose of this in vitro study was to evaluate the sealing ability of injection molded thermoplasticized gutta percha and lateral condensation techniques with and without the use of sealers. Materials and Methods: Forty freshly extracted adult human maxillary central incisors with complete formed apices were utilized in this study. The teeth were randomly divided into four groups for evaluation of the apical seal. Group (1) lateral condensation gutta percha technique without sealer, (2) lateral condensation gutta percha technique with sealer, (3) Inject
... Show MoreBackground: The marginal fit is the most characteristic that closely related to the longevity or success of a restoration, which is absolutely affected by the fabrication technique. The objective of present in vitro study was to evaluate the effect of four different CAD/CAM systems on the marginal fit of lithiµm disilicate all ceramic crowns. Materials and Methods: Adentoform tooth of a right mandibular first molar was prepared to receive all ceramic crown restoration with deep chamfer finishing line (1mm) and axial reduction convergence angle of 6 degree, dentoform model duplicated to have Nickel-Chromiµm master die. Thirty two stone dies produce from master die and distributed randomly in to four groups (8 dies for each group) accor
... Show MoreThe melting duration in the photovoltaic/phase-change material (PV/PCM) system is a crucial parameter for thermal energy management such that its improvement can realize better energy management in respect to thermal storage capabilities, thermal conditions, and the lifespan of PV modules. An innovative and efficient technique for improving the melting duration is the inclusion of an exterior metal foam layer in the PV/PCM system. For detailed investigations of utilizing different metal foam configurations in terms of their convective heat transfer coefficients, the present paper proposes a newly developed mathematical model for the PV/PCM–metal foam assembly that can readily be implemented with a wide range of operating condition
... Show MoreDuctal carcinoma in situ is the most commonly diagnosed early stage breast cancer. The efficacy of intraductally delivered poly(ethylene glycol)‐doxorubicin (PEG‐DOX) nanocarriers, composed of one or more DOX conjugated to various PEG polymers, was investigated in an orthotopic ductal carcinoma in situ‐like rat model. In vitro cytotoxicity was evaluated against 13762 Mat B III cells using MTT assay. The orthotopic model was developed by inoculating cancer cells into mammary ducts of female Fischer 344 retired breeder rats. The ductal retention and in vivo antitumour efficacy of two of the six nanocarriers (5 kDa PEG‐DOX and 40 kDa PEG‐(DOX)4) were investigated based o
Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner re
... Show MoreThe effect of Low-Level Laser (LLL) provided by green semiconductor laser with an emission wavelength of 532 nm on of human blood of people with brain and prostate cancer has been investigated. The effect of LLL on white blood cell (WBC), NEUT, LYMPH and MONO have been considered. Platelet count (PLT) has also been considered in this work. 2 ml of blood sample were irradiating by a green laser of the dose of 4.8 J/cm2. The results suggest a potential effect of LLL on WBC, PLT, NEUT, LYMPH, and MONO of people with brain and prostate cancer Key words: white blood cell , platelet , low-level laser therapy