ABSTRACT Background: work-related musculoskeletal disorders represent an important occupational health issues among dentists especially neck and low back complaints. Biomarkers of tissue damage as results of occupational physical demands could be used for detection of work related musculoskeletal disorders. Aim: The aim of this study was to assess work- related musculoskeletal disorders, physical work load index, selected salivary biomarkers (Creatine kinase and C - reactive protein) and to find the relation among them. Subjects and Methods: Study participants are consisted of 112 dentists. They were selected from college of dentistry /Baghdad University, health care center in Bagdad city. They were of both gender and aged between 40-45 years .they should fit the study criteria. Self-administered standardized Nordic questionnaires were used to evaluate musculoskeletal complaints. Physical work load was evaluated by used physical work load index. Stimulated saliva were collected from subsample (87) dentists drawn randomly from the total sample, for whom biochemical analysis (measurement of creatine kinase and C - reactive protein) were done. Results: Results showed that low back and neck complaints is the most complaint experienced by the dentists with percentages of ( 69.6% and 66.1% ), followed by the shoulder complaint (49.1% ) while the hip complaint showed the lowest percentage (13.4%).According to severity scores ,both low back and neck musculoskeletal complaints were of score 3 severity (score 3 constituted the highest percentages in both area (27.7% ,23.2%respectively) as compared to other severity scors.For shoulder complaint it was of score 2 severity (score 2 constituted the highest percentage 23.2% as compared to other severity scores, The musculoskeletal complaints(proximal ,neck, shoulder and low back) had higher mean rank values in the highest quartile of Physical work load index with non – significant differences (P<0.05). Regarding salivary creatine kinase the proximal ,total and low back complaints had higher mean rank values among dentists with highest Creatine kinase quartile , while distal manifestations ,neck and shoulder complaints had higher mean rank value in the average interquartile range of Creatine kinase with non – significant differences( P<0.05). For c- reactive protein almost all the complaints(proximal , total ,neck and shoulder) had higher mean rank values in the first lowest quartile with non – significant differences( P<0.05). Conclusions: Physical work load increase the risk of musculoskeletal disorders occurrence. Salivary creatine kinase could serve as a biomarker that reflects the underlying of musculoskeletal complaints more than C - reactive protein. Further studies that used more objective tools for assessing musculoskeletal disorders is needed.
Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported
... Show MoreIn this paper, some series of new complexes of Mn(II), Co(II), Ni (II) Cu(II) and Hg(II) are prepared from the Schiff bases (L1,L2). (L1) derived from 4-aminoantipyrine and O-phenylene dia mine then (L2) derived from (L1) and 2-benzoyl benzoic acid. Structural features are obtained from their elemental microanalyses, molar conductance, IR, UV–Vis, 1H, 13CNMR spectra and magnetic susceptibility. The magnetic susceptibility and UV–Vis, IR spectral data of the ligand (L1) complexes get square–planar and tetrahedral geometries and the complexes oflig and (L2) get an octahedral geometry. Antimicrobial examinations show good results in the sharing complexes.
The study involved preparing a new compound by combining Schiff bases generated from compounds for antipyrine, including lanthanide ions (lanthanum, neodymium, erbium, gadolinium, and dysprosium). The preparation of the ligand from condensation reactions (4-antipyrinecarboxaldehyde with ethylene di-amine) at room temperature, and was characterization using spectroscopic and analytical studies ( FT-IR, UV-visible spectra, 1H-NMR, mass spectrometry, (C.H.N.O), thermogravimetric analysis (TGA), in addition to the magnetic susceptibility and conductivity measurement of the synthesis complexes, among the results we obtained from the tests, we showed that the ligand behaves with the (triple Valence) lanthanide ions, the multidentate
... Show MoreAssessing water quality provides a scientific foundation for the development and management of water resources. The objective of the research is to evaluate the impact treated effluent from North Rustumiyia wastewater treatment plant (WWTP) on the quality of Diyala river. The model of the artificial neural network (ANN) and factor analysis (FA) based on Nemerow pollution index (NPI). To define important water quality parameters for North Al-Rustumiyia for the line(F2), the Nemerow Pollution Index was introduced. The most important parameters of assessment of water variation quality of wastewater were the parameter used in the model: biochemical oxygen demand (BOD), chemical oxygen dem
This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show MoreMost companies use social media data for business. Sentiment analysis automatically gathers analyses and summarizes this type of data. Managing unstructured social media data is difficult. Noisy data is a challenge to sentiment analysis. Since over 50% of the sentiment analysis process is data pre-processing, processing big social media data is challenging too. If pre-processing is carried out correctly, data accuracy may improve. Also, sentiment analysis workflow is highly dependent. Because no pre-processing technique works well in all situations or with all data sources, choosing the most important ones is crucial. Prioritization is an excellent technique for choosing the most important ones. As one of many Multi-Criteria Decision Mak
... Show MoreActivated carbon prepared from date stones by chemical activation with ferric chloride (FAC) was used an adsorbent to remove phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) from aqueous solutions. The influence of process variables represented by solution pH value (2-12), adsorbent to adsorbate weight ratio (0.2-1.8), and contact time (30-150 min) on removal percentage and adsorbed amount of Ph and PNPh onto FAC was studied. For PNPh adsorption,( 97.43 %) maximum removal percentage and (48.71 mg/g) adsorbed amount was achieved at (5) solution pH,( 1) adsorbent to adsorbate weight ratio, and (90 min) contact time. While for Ph adsorption, at (4) solution pH, (1.4) absorbent to adsorbate weight ratio, and (120 min) contact
... Show MoreThis study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu
... Show More