ABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental implants were inserted and the implant stability quotient (ISQ) measures for primary stability documented by Osstell device. Results: For both groups fixtures introduced in the mandible showed a higher stability (74 and 71.85) respectively and was lower in maxilla. The mean primary stability of group A was 70.21 (ranged from 51-83), while for group B was 68.55 (46.5-81). Conclusion: primary stability influencing osseointegration and subsequent long term success. It was higher in association with delayed implant placement, mandible, and increased implant diameters.
The accelerating effect of 1,4- phenylenediamine (PDA) additions in 1M hydrochloric acid solution at temperature rang (20-60) C° has been studied by weight losses measurement during ranging time (1-260) h and by following the pb2+ concentration in solution after several times by using Atomic absorption spectroscopy (AAS) . The volume of hydrogen gas involving was followed also in presence and absence of (PDA) in the corrosive solution .Accelerating enhanced by adding (NaCl , NaBr , NaI ) was also investigated.
Abstract Twelve isolates of bacteria were obtained from samples of different soils and water amended with 100µg/ml of five heavy metals chlorides (i.e: Aluminum Al+2, Iron Fe+2, Lead Pb+2, Mercury Hg+2 and Zinc Zn+2). Four isolates were identified as Bacillus subtilis and B. subtilis (B2) isolate was selected for this study according to their resistance to all five heavy metals chlorides. The ability of B. subtilis (B2) isolate for growing in different concentration of heavy metals chlorides ranging from 200-1200 µg/ml was tested. The highest conc. that B. subtilis (B2) isolate tolerate was 1000 µg/ml for Al+2, Fe+2, Pb+2, and Zn+2and 300 µg/ml for Hg+2 for 24hour. The effect of heavy metals chlorides on bacterial growth for 72 hrs was
... Show MoreAutorías: Jehan Faris Yousif, Read Idrees Mahmood. Localización: Utopía y praxis latinoamericana: revista internacional de filosofía iberoamericana y teoría social. Nº. 1, 2020. Artículo de Revista en Dialnet.
Purpose: To evaluate the effect of intravitreal Aflibercept injection on wet AMD both functionally and anatomically after loading doses. The secondary aim is to evaluate the effect of risk factors including (gender, age, smoking, hypertension, and diabetes meatus) on the patient’s response. Study Design: Interventional case series. Place and Duration of Study: Al-Haitham Eyes Teaching Hospital in Baghdad, Iraq, from November 2021 and September 2022. Methods: Fifty eyes of 47 patients with treatment naïve wet AMD were selected through convenient sampling. Data were collected for age, gender, smoking, and chronic disease. Clinical examination, best corrected visual acuity (BCVA), optical coherence tomography angiography
... Show MoreBackground: The vertical distance between the upper and lower incisal edge of the central incisors when the mouth is opened as wide as possible is called maximum mouth opening (MMO). Any pathological change in the masticatory system had a direct effect on the maximal mouth opening. The aim of this study was to evaluate the relationship between the maximum bite force and the maximum mouth opening among group of children. Materials and methods: Four hundred children of both genders were included in this study, their age ranged from eight to ten years. Anterior and posterior (right, left) bite force were measured using bite force sensor. Maximum mouth opening was evaluated by electronic digital caliper. Data was statistically analyzed
... Show MoreBackground: The vertical distance between the upper and lower incisal edge of the central incisors when the mouth is opened as wide as possible is called maximum mouth opening (MMO). Any pathological change in the masticatory system had a direct effect on the maximal mouth opening. The aim of this study was to evaluate the relationship between the maximum bite force and the maximum mouth opening among group of children. Materials and methods: Four hundred children of both genders were included in this study, their age ranged from eight to ten years. Anterior and posterior (right, left) bite force were measured using bite force sensor. Maximum mouth opening was evaluated by electronic digital caliper. Data was statistically analyzed by de
... Show MoreBackground: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirement. The purpose of this study was to evaluate the effect of addition of 3% wt of treated (silanized) Titanium oxide Nano filler on some physical and mechanical properties of heat cured acrylic denture base material. Materials and methods: 100 specimens were constructed, 50 specimens were prepared from heat cure PMMA without additives (control) and 50 specimens were prepared from heat cure PMMA with the addition of TiO2 Nano fillers. Each group was divided into 5 sub groups according to the test performed which was mixed by probe ultra-sonication machine. Results: A highly
... Show More