Preferred Language
Articles
/
jbcd-1747
Evaluation of Osseointegration of Dental Implants Prepared by Piezosurgery (Clinical Study)
...Show More Authors

ABSTRACT Background: Piezosurgery device is a system developed recently to overcome the limitation of the traditional surgical technique in implant site preparation, which use the principle of ultrasonic microvibrations to create precise & selective cut in bone in harmony with the surrounding tissues. The aim of this study was to evaluate the outcomes of implants inserted by ultrasonic implant site preparation protocol (UISP) using piezosurgery device, regarding the survival rate, stability and other related factors, at 16 weeks postoperative follow up period. Materials and Methods: A total of (24) patients, (6) males and (18) females, aged between (19-51) years old, contributed in this study receiving a total of (42) implants, all of these implants bed were prepared by means of special tips mounted in piezosurgery device. For each patient thorough clinical and radiographical preoperative assessment was applied. Implant stability quotient (ISQ) values were measured at baseline, 8 weeks and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient for 16 weeks postoperatively. Results: (24) patients received (42) implants accomplished the follow-up period, After 16 weeks all implants (42) were osseointegrated and the overall implants survival rate was 100% with no failure and no complication was observed. The mean ISQ value at baseline was (74.32±6.42), the mean ISQ value at 8 weeks was (72.62±9.05) and at 16 weeks the mean ISQ (±SD) value was (76.68±7.35) the changes in the mean stability during the healing period showed significant increase in the implant stability (P≤0.05). At the 16th week the number of implants that achieved ISQ≥70 was 35 (83.3%), and 7 implants attained ISQ> 70 (16.7%). Conclusions: high and significant survival rate, significant secondary stability, early positive shifting of the mean ISQ value, no remarkable complications in implants inserted by ultrasonic implant site preparation indicated that piezosurgery is a reliable alternative and safe method used in dental implant osteotomy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
Nanocrystalline -Silicon Carbide Films Prepared by TEACO2 Laser
...Show More Authors

Thin films of microcrystalline and nanocrystalline -silicon carbide and silicon, where deposited on glass substrate with substrate temperature ranging from 350-400C, with deposition rate 0.5nm per pulse, by laser induced chemical vapor deposition. The deposition induced by TEACO2 laser. The reactant gases (SiH4 and C2H4) photo decompose throughout collision associated multiple photon dissociate. Such inhomogeneous film structure containing crystalline silicon, silicon carbide and amorphous silicon carbide matrix, give rise to a new type of material nanocrystalline silicon carbide in which the optical transmittance is governed by amorphous SiC phase while nanocrystalline grain are responsible for the conduction processes. This new m

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
In Vitro Release Study on Capsules and Tablets Containing Enteric - Coated Granules Prepared by Wet Granulation
...Show More Authors

Wet granulation method was used instead of conventional pan coating  or fluidized –bed coating technique to prepare enteric-coated diclofenac sodium granules, using ethanolic solution of EudragitTM L100 as coating, binding and granulating agent .Addition of PEG400 or di-n-butyl phthalate as a plasticizer was found to improve the enteric property of the coat.

Part of the resulted granules was filled in hard gelatin capsules (size 0), while the other part was compressed into tablets with and without disintegrant.

The release profile of these two dosage forms in 0.1N HCl (pH 1.2)for 2 hours, and in phosphate buffer (pH 6.8) for 45 minutes as well as the release kinetic were compared with that of the en

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 04 2019
Journal Name
American Association Of Pharmaceutical Scientists
Recent advances in polymeric implants
...Show More Authors

Implantable drug delivery systems, such as drug pumps and polymeric drug depots, have emerged as means of providing predetermined drug release profiles at the desired site of action. While initial implants aimed at providing an enduring drug supply, developments in polymer chemistry and pharmaceutical technology and the growing need for refined drug delivery patterns have prompted the design of sophisticated drug delivery implants such as on-demand drug-eluting implants and personalized 3D printed implants. The types of cargo loaded into these implants range from small drug molecules to hormones and even therapeutic cells. This review will shed light upon recent advances in materials and composites used for polymeric implant fabrication, hi

... Show More
View Publication
Publication Date
Tue Sep 03 2019
Journal Name
Aaps Pharmscitech
Recent Advances in Polymeric Implants
...Show More Authors

View Publication
Scopus (31)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Study of the heat treatment effect on electrical and porosity of Cermet Coating layers (Zro2 – Y2O3) prepared by Thermal Spraying
...Show More Authors

The technical of Flame Thermal Spray had been used in producing a cermet
composite based on powders of stabilized zirconium oxide containing amount of
Yatteria oxide (ZrO2- 8Y2O3) reiforced by minerals powders of bonding material
(Ni-Cr- Al- Y) in different rates of additions (25, 35, 50) on stainless steel base type
(304) after preparing it by the way of Grit Blasting.
Before heat treatment, the coated cermet layers were characterized for porosity
and electric resistivity. All samples were heat treated in vacuum furnace at different
temperature and times. The physical tests had been operated after heat treatment
and gave best results especially porosity, which found to be reduced dramatically
and producing hig

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of Annealing on Optical and Electrical Properties of ZnS Thin Film Prepared by CO2 Laser Deposition Technique
...Show More Authors

In this work, ZnS thin films have been deposited by developed laser deposition technique on glass substrates at room temperature. After deposition process, the films were annealed at different temperatures (200ºC , 300 ºC and 400ºC ) using thermal furnace.The developed technique was used to obtain homogeneous thin films of ZnS depending on vaporization of this semiconductor material by continuous CO2 laser with a simple fan to ensure obtaining homogeneous films. ZnS thin films were annealed at temperature 200ºC, 300 ºC and 400ºC for (20) minute in vacuum environment. Optical properties of ZnS thin film such as absorbance, transmittance, reflectance, optical band gap, refractive index extinction coefficient and absorption coefficien

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 15 2015
Journal Name
Journal Of Physical Vapor Deposition Science And Technology (jpvdst)
Physical Properties of Nanostructured Silicon Dioxide Prepared by Pulsed-Laser Deposition
...Show More Authors

Publication Date
Mon Oct 03 2022
Journal Name
Optik
Enhancement the photosensitivity of PVA NFs/Si prepared by electrospinning technique
...Show More Authors

This work aimed PVA nanofibers in a range of concentrations were successfully manufactured via electrospinning. PVA NFs/Si was effectively prepared using the electrospinning process. The structural, morphological, optical and electrical properties of the prepared PVA were studied using XRD, FE-SEM, UV-Vis spectrophotometer and I-V characteristics, respectively. The amorphous structure of PVA nanofibers was observed. The optical energy gap from ultraviolet to visible was between (2.75 and 2.41) eV, making this compound highly sensitive to visible orange light at 610 nm, with a photosensitivity of 66%. The optical energy gap of PVA/Si heterojunction was utilized to modify this film from the UV to the visible spectrum. As show in the results,

... Show More
Scopus (8)
Scopus
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic investigation of Rhodamine-B thin film prepared by PLD technique
...Show More Authors

Optical properties of Rhodamine-B thin film prepared by PLD
technique have been investigated. The absorption spectra using
1064nm and 532 nm laser wavelength of different laser pulse
energies shows that all the curves contain two bands, B band and Q
bands with two branches, Q1 and Q2 band and a small shift in the
peaks location toward the long wavelength with increasing laser
energy. FTIR patterns for Rhodamine-B powder and thin film within
shows that the identified peaks were located in the standard values
that done in the previous researches. X-ray diffraction patterns of
powder and prepared Rhodamine-B thin film was display that the
powder has polycrystalline of tetragonal structure, while the thin film

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Oct 04 2022
Journal Name
International Journal Of Dentistry
Comparison between Rolled and Nonrolled U-Shaped Flap in the Second Stage of Dental Implant Surgery: A Randomized Clinical Trial
...Show More Authors

Background. The presence of black triangles around the dental implant-supported prosthesis and the failure to construct adequate papillae around them bothers dental implantologists. Peri-implant surgical soft tissue management will improve esthetics, function, and implant survival. Aim. To compare the effects of rolled and nonrolled U-shaped flaps combined with a temporary crown in enhancing the soft tissue around dental implants. Materials and Methods. Forty patients were included in this study; all patients were operated on by the same maxillofacial surgeon at Al-Iraq specialized dental clinics from January 2019 to January 2020. Patients were divided randomly into two groups: group A: at the second stage of implant surgery, a U-sh

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref