ABSTRACT Purpose: the aim of this in vitro study was to compare the marginal gap and internal fitness between single crowns and the crowns within three-unit bridges of zirconium fabricated by CAD-CAM system. Materials and methods: A standard model from ivoclar company was used as a pattern to simulate three-units bridge (upper first molar and upper first premolar) as abutments used to fabricate stone models, eight single crowns for premolar and eight of three units bridges. Crowns and bridges fabricated by CAD-CAM system were cemented on their respective stone models then sectioned at the mid-point buccolingaully and misiodistaly and examined under stereomicroscope. Result: the marginal gap in premolar crowns and premolar within bridge were within the acceptable value 120µm, one –way ANOVA showed that there was significant differences in the internal gaps among the areas. Independent t- Test showed there was significant differences between the premolar crowns and premolar crowns within bridges in marginal opening and cusp tip (lingually and distally) Conclusion: the marginal and internal gaps were in the bridge higher than those in the crowns. The areas of sloped surfaces such as chamfer area, occlusal area and cusp tip had high gap values in comparison with areas of flat surfaces such as axial wall and when the surface area of abutment increased, the marginal and internal gaps of abutment was increase.
According to the measuring the relationship between organizational loyalty and job satisfaction among staff members at one college in the higher education ministry in Iraq by using exploratory factor analysis methods to extraction the components which have the major effects on the variables related to organizational loyalty and job satisfaction .
The research contains four basic topics، the first section related to methodology and regarding the conceptual framework it is discussed in the second section، and the third section concentrated at the presentation and the analysis Scientific results and practical results are section presented in the fourth.
The current research is concerned with studying the decisive answers which are considered quick and conclusive. These answers can effectively interrupt the opponent's argument and close the dialogue.This research is concentrated on deliberative methodology focusing on the decisive answer's activity and ending them through several completing and argument sides. This research consists of an introduction and three parts, the current introduction is focused the light on the concept of decisive answers and its uses in literature and the scarce of speech, and how to consider it with one dialogue description,that dialogue constitute by ? The first part is concerned with those answers through the deliberative methodology and classifying decisive
... Show Moreيهتم هذا البحث بدراسة الأجوبة المسكتة,وهي أجوبة سريعة وحاسمة تقطع حجة الخصم وتفحمه وتغلقالحوار.وقد أرتكز البحث على منهجية تداولية تنظرإلى فاعلية الجواب المسكت في المحاورة وإنهائها من زواياإنجازية و حجاجية.وقد تكون البحث من ديباجة ممهدةوثلاثة مباحث.وسلطتالديباجةالممهدةالضوء علىمفهومالجواب المسكتوشيوعهفي كتب الأدبوالأخبارونوادر الكلاموكيف يمكن النظر لهبوصفه وحدة حوارية تنبنيمنها المحادثة؟أما المبحث ا
... Show MoreABSTRACT: Polypyrrole and polypyrrole / silver nanocomposites were fabricated by in-situ polymerization employing Ammonium Persulphate as an oxidizing agent. Nanocomposites were synthesized by combining polypyrrole and silver nanoparticles in various weight percentages (0.1%, 0.5%, 3%, 5% and 7% wt.). Crystallographic data were collected using X-ray diffraction. PPy particles were found to have an orthorhombic symmetry. In contrast, PPy/Ag nanocomposites were reported to have monoclinic structure. The crystallite size was determined by XRD using Scherrer equation and considered to be within 49 nm range. DC conductivity of pelletized samples was evaluated in the temperature range of 323.15k to 453.15k. The conductivity displayed an
... Show MoreABSTRACT: Polypyrrole and polypyrrole / silver nanocomposites were fabricated by in-situ polymerization employing Ammonium Persulphate as an oxidizing agent. Nanocomposites were synthesized by combining polypyrrole and silver nanoparticles in various weight percentages (0.1%, 0.5%, 3%, 5% and 7% wt.). Crystallographic data were collected using X-ray diffraction. PPy particles were found to have an orthorhombic symmetry. In contrast, PPy/Ag nanocomposites were reported to have monoclinic structure. The crystallite size was determined by XRD using Scherrer equation and considered to be within 49 nm range. DC conductivity of pelletized samples was evaluated in the temperature range of 323.15k to 453.15k. The conductiv
... Show MoreThe posterior regions of the jaws usually represent a significant risk for implant surgery. A non-valid assessment of the available bone height may lead to either perforation of the maxillary sinus floor or encroachment of the inferior alveolar nerve and consequently to implant failure. This study aimed to evaluate the reliability of surgeon’s decision in appraising the appropriate implant length, in respect to vital anatomical structures, using panoramic radiographs.
Only implants that are inserted in relation to the maxillary sinus (MS) or the mandibular canal (MC) were enrolled
The aim of this research is to estimate the parameters of the linear regression model with errors following ARFIMA model by using wavelet method depending on maximum likelihood and approaching general least square as well as ordinary least square. We use the estimators in practical application on real data, which were the monthly data of Inflation and Dollar exchange rate obtained from the (CSO) Central Statistical organization for the period from 1/2005 to 12/2015. The results proved that (WML) was the most reliable and efficient from the other estimators, also the results provide that the changing of fractional difference parameter (d) doesn’t effect on the results.
Background: Painful elbow joint over the lateral epicondyle especially with resisted wrist extension are common signs of lateral epicondyle tendinopathy, also called tennis elbow. Objective: To evaluate the clinical outcome of local platelet rich plasma (PRP) injection in patients with chronic tennis elbow compared with a steroid (Depomedrol 40 mg) injection. Methods: A total of 88 patients with chronic tennis elbow were treated at Al-Kindy Teaching Hospital and private clinics. All patients had chronic pain for about 24 weeks or more and had failed first line treatment. The patients dividing into two groups, Group A injected with PRP (n = 44), and group B injected with depomedrol 40 mg (n = 44). A good clinical result w
... Show MoreBackground: Painful elbow joint over the lateral epicondyle especially with resisted wrist extension are common signs of lateral epicondyle tendinopathy, also called tennis elbow.
Objective: To evaluate the clinical outcome of local platelet rich plasma (PRP) injection in patients with chronic tennis elbow compared with a steroid (Depomedrol 40 mg) injection.
Methods: A total of 88 patients with chronic tennis elbow were treated at Al-Kindy Teaching Hospital and private clinics. All patients had chronic pain for about 24 weeks or more and had failed first line treatment. The patients dividing into two groups, Group A injected with PRP (n = 44), and group B injected with d
... Show MoreThe study aims to achieve several objectives, including follow-up scientific developments and transformations in the modern concepts of the Holistic Manufacturing System for the purpose of identifying the methods of switching to the entrances of artificial intelligence, and clarifying the mechanism of operation of the genetic algorithm under the Holonic Manufacturing System, to benefit from the advantages of systems and to achieve the maximum savings in time and cost of machines Using the Holistic Manufacturing System method and the Genetic algorithm, which allows for optimal maintenance time and minimizing the total cost, which in turn enables the workers of these machines to control the vacations in th
... Show More