ABSTRACT Background: One of the challenges to use chlorhexidine is its effect on the amount of microleakage after restoration; however, use of the materials with antibacterial properties after tooth preparation and before restoration has been widespread. The objective of this, in-vitro, study was to evaluate the influence of consepsis (chlorhexidine gloconate disinfectant) application on microleakage in class II cavities restored with light cured composite using universal adhesive system; etch and rinse technique –self etch technique. Materials and Methods: Forty class II cavities were prepared on mesial and distal surfaces of 20 non-carious mandibular third molars. The cavities were divided into four groups; (n =10 for each group). G1: cavities were bonded with (single bond universal adhesive, 3MESPE) after etching with 35% phosphoric acid - etch and rinse technique, without chlorhexidine , G2: chlorhexidine was used after etching with 35% phosphoric acid, then cavities were bonded with (single bond universal adhesive, 3MESPE) - etch and rinse technique . G3: cavities were bonded with (single bond universal adhesive, 3MESPE) - self etch technique, without chlorhexidine, G4: The chlorhexidine was used before bonding. All groups were restored with non – hybrid composite resin (Z 350, 3MESPE). Micrlerackage was evaluated at gingival margin using methylene blue dye penetration method. In each cavity the dye penetration in millimeters was measured by strereomicroscope. Statistical analysis for the data was carried out using one-way ANOVA and LSD test. Results: Group G2 produced the least microleakage which is statistically highly significantly different than the remaining groups. Group G3 produced the highest microleakage which is statistically high significant difference than G1 and G2, but the difference is not significant with group G4. Conclusions: Consepsis can be used as cavity disinfectants when restoring the cavities with single bond universal adhesive as etch and rinse technique. However, its effect seems to be lower when using the single bond universal adhesive as self-etch technique.
the use of diffrent concectration of Na and Mg ions were shown to causes in increase in the bindings at oncentration
This study aimed to investigate the influence of longitudinal steel embedded tubes located at the center of the column cross-section on the behavior of reinforced concrete (RC) columns. The experimental program consisted of 8 testing pin-ended square sectional columns of 150×150 mm, having a total height of 1400 mm, subjected to eccentric load. The considered variables were the steel square tube sizes of 25, 51 and 68 mm side dimensions and the load eccentricity (50 and 150) mm. RC columns were concealed steel tubes with hollow ratios of 3%, 12% and 20% depending on tube sizes used. The experimental results indicated an improvement in the overall behavior of eccentric columns when steel embedded tubes are used. The maximum gain in
... Show MoreAbstract
Objective(s): To evaluate the nurses` practices for children who diagnosed with febrile convulsion.
Methodology: A quantitative research, descriptive correlational design was used in this study, the study conducted on nurses who work in Al-Diwaniya Pediatrics Teaching Hospital-Iraq for Maternal and Children period from 12th September 2021 to 10th October 2022. A non- probability (convenience) sample has been applied to obtain the study goals. The study sample was (21) nurses who participate in the study. The study tool is composed of two parts: The first part is concerned with collection of nurses socio-demographic data obta
... Show MoreA long-span Prestressed Concrete Hunched Beam with Multi-Quadrilateral Opening has been developed as an alternative to steel structural elements. An experimental program was created and evaluated utilizing a single mid-span monotonic static load on simply supported beams, which included six beams with openings and the solid control beam without openings, to investigate the performance of such beams. The number and height of the quadrilateral openings are the variables to consider. According to test results, the presence of openings in the prestressed concrete hunched beam with multi-quadrilateral opening did not considerably affect their ultimate load capacity with respect to a contro
Test results of six half-scale reinforced concrete flat plates connections with an opening in the vicinity of the column are reported. The test specimens represent a portion of a slab bounded by the lines of contraflexure around the column. The tests were designed to study the effect of openings on the punching shear behavior of the slab-column connections. The test parameters were the location and the size of the openings. One specimen had no opening and the remaining five had various arrangements of openings around the column. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The openings in the specimens were square, with the sides parallel to the sides of the column. Three sizes of ope
... Show MoreThe study included the investigation of fungi which associated with heavy animal's leather (Cows and Buffalos) and light (Sheep’s and Goats )through different processing stages (raw hides ,dehairing ,pickling,chrome tanned and stainning or finished stages)there were 10 genera and 25 species in addition to sterile fungi associated with animal leathers which included Alternaria ,Aspergillus,Cladosporium,Fusarium, Mucor , Penicillium , Rhizopus , and Trichoderma .Aspergillus and Penicillium have observed in all leather samples and different processing stages, and that the first time isolate two genera Helminthosporium , Stemphylium form leather for staining stage.
Abstract : A descriptive study was conducted out patient in Neuralgic Hospital and Teaching Baghdad Teaching Hospital from 1st July / 2004 through October 1st / 2004 . in order to assess with QOL for CVA patients , the study aimed to identifying the QOL domain of ( physical , psychological , level of independence , social and environment ) and it relation with some demographic characteristic which is related to those patients .A purposive sample of ( 50 ) CVA patients who selected from out patient clinic of hospitals . A development questionnaire was structured and is adopted of WHO quality of life qu
In this research, the efficiency of low-cost unmodified wool fibers were used to remove zinc ion from industrial wastewater. Removal of zinc ion was achieved at 99.52% by using simple wool column. The experiment was carried out under varying conditions of (2h) contact time, metal ion concentration (50mg/l), wool fibers quantity to treated water (70g/l), pH(7) & acid concentration (0.05M). The aim of this method is to use a high sensitive, available & cheep natural material which applied successfully for industrial wastewater& synthetic water, where zinc ion concentration was reduced from (14.6mg/l) to (0.07mg/l) & consequently the hazardous effect of contamination was minimized.
The robot arm is the most popular robotic form used in industry. Thus, it is crucial to make a system programming which could controlled the movement of each part in the industrial robot to make it works properly. One of the simplest models of the robot arm is EDARM ED-7100 which has a controller to control the movement of the robot arm manually. In this study, the robot controller has been redesigned in order to improve this robot's function. The new controller system used AT89S52 microcontroller which has wire connected to the robot hand. A function has been added with this controller to improve the system of controlling and becomes better than the previous system (only manually). The functions of the new system include three mo
... Show MorePolymer blended electrolytes of various concentrations of undoped PAN/PMMA (80/20, 75/25, 70/30, 65/35 and 60/40 wt%) and doped with lithium salts (LiCl, Li2SO4H2O, LiNO3, Li2CO3) at 20% wt have been prepared by the solution casting method using dimethylformamide as a solvent. The electrical conductivity has been carried out using an LCR meter. The results showed that the highest ionic conductivity was 2.80x10-7 (Ω.cm)-1 and 1.05x10-1 (Ω.cm)-1 at 100 kHz frequency at room temperature for undoped (60% PAN + 40% PMMA) and (80% PAN + 20% PMMA) doped with 20%wt Li2CO3 composite blends, respect
... Show More