Background: Thalassemia is a hereditary anemia resulting from defects in hemoglobin production. ?- thalassemia caused by decrease in the production of ?- globin chains affect multiple organs and is associated with cranio-oro-facial deformity which include prominent cheek bones and protrusive premaxilla with depression of the nasal bridge often referred to as “rodent or chip-munk face” with small mandible and Cl.II skeletal relationship. This study aimed to investigate cephalometric craniofacial parameters (skeletal) of ?- thalassemic major patients by using computed tomography and to compare findings with a group of healthy patients in the same age group. Subject, Materials and Method: The study included (40) patients with ?- thalassemic major (20 female and 20 male) with age 8-15years compared with (40) healthy controls (20 female and 20 male) with the same age, who admitted to spiral computed tomography scan unit in X-ray institute in AL-KARKH general hospital to have computed tomography scan for the brain, paranasal and for orthodontic purpose from October 2011 to June 2012. Cephalometric analysis of the selected four skeletal linear measurements and four skeletal angular measurements, by using direct analysis with software programs in a computer which is part of the computed tomography machine. Results: There was no statistically significant difference between thalassemic males and females in all selected skeletal linear and angular measurements, Thalassemic patients have a highly significant large ANB angle and cl II skeletal relationship, significant larger gonial angle, Mandibular base length (Me-Go) is significantly shorter, Retrognathic mandible (SNB) is significantly decreased, highly significant shorter in total anterior facial height (N-Me) and total posterior facial height (S-Go), and also the Ramus height is highly significant decreased. Conclusion: In thalassemic patients, the skeletal morphology is recognizable and mandible is retrognathism and they have skeletal cl. II pattern and Computed tomography is useful tool for assessment of the cranio facial measurement.
The degradation and mineralization of 4-chlorophenol (4-CP) by advanced oxidation processes (AOPs) was investigated in this work, using both of UV/H2O2 and photo-Fenton UV/H2O2/Fe+3 systems.The reaction was influenced by the input concentration of H2O2, the amount of the iron catalyst, the type of iron salt, the pH and the concentration of 4-CP. A colored solution of benzoquinon can be observed through the first 5 minutes of irradiation time for UV/H2O2 system when low concentration (0.01mol/L) of H2O2 was used. The colored solution of benzoquinon could also be observed through the first 5 minutes for the UV/H2O2/Fe+3 system at high
concentration (100ppm) of 4-CP. The results have shown that adding Fe+3 to the UV/H2O2 system enhanced
The presence of residual antibiotics in water results in the development of antibiotics resistant genes. The available wastewater treatment systems are not capable of removing such antibiotics from sewage. Thus, antibiotics need to be removed before the discharge of wastewater. Adsorption is among the promising techniques for the wastewater treatment to aid the removal of a wide range of organic and inorganic pollutants. The present work is a contribution to the search for an economical method for the removal of low concentrations of amoxicillin (AMX) from water by adsorption on water treatment residue, WTR, taken from a local drinking water facility. The chemical composition and the adsorptive characteristics of the material were first
... Show Moreيهدف البحث الحالي إلى الاستفادة من القهوة المستهلكة , كمادة وسيطة حيث تعد القهوة المستهلكة من المخلفات المضرة للبيئة الاستخراج الكافيين الطبيعي والذي يعد مادة ذات نشاط حيوي واهمية, وتحديد العوامل الفعالة في كفاءة عملية الاستخلاص من حيث تركيز الكافيين. تضمنت المتغيرات الرئيسية المدروسة وقت الاستخلاص 0-150 دقيقة ، ودرجة الحرارة 25-55 درجة مئوية ، وسرعة الخلط 180-450 دورة في الدقيقة ، ودرجة الحموضة العالق
... Show MoreThis work aimed PVA nanofibers in a range of concentrations were successfully manufactured via electrospinning. PVA NFs/Si was effectively prepared using the electrospinning process. The structural, morphological, optical and electrical properties of the prepared PVA were studied using XRD, FE-SEM, UV-Vis spectrophotometer and I-V characteristics, respectively. The amorphous structure of PVA nanofibers was observed. The optical energy gap from ultraviolet to visible was between (2.75 and 2.41) eV, making this compound highly sensitive to visible orange light at 610 nm, with a photosensitivity of 66%. The optical energy gap of PVA/Si heterojunction was utilized to modify this film from the UV to the visible spectrum. As show in the results,
... Show MoreThe presence of dyes in wastewater has become a major issue all over the world. The discharge of dyes in the environment is concerned for both toxicological and esthetical reasons. In this study, the removal of dyes from aqueous solution by electrocoagulation using aluminum electrodes as cathode and anode were investigated with the electrocoagulation cell of 1litter. The study included: the impact of various operating parameters on the dyes removal efficiency like pH, NaCl concentration, distance between electrodes, voltage, initial dyes concentration and type of electrodes. The dye (congo red) concentrations were (50, 100, 150, and 200 ppm), stirring speed was 120 rpm at room temperature. pH used was maintained constant
... Show MoreSilymarin (SM) is a plant extract obtained from Silybum marianum( milk thistle) . It is class II type drug according to Biopharmaceutics Classification System with low bioavailability due to its low solubility.
Micro/nanonization during crystallization, surface modification and crystal structure modification may improve the dissolution rate of poorly water-soluble drugs.
The aim of this study was to increase the water solubility and dissolution rate of SM by in-situ micronization using solvent change either by stirring or ultrasonic method. Stabilizers like Gelatin, PVP-K30, HPMC15, Pulullan were used to stabilize the prepared ultrafine crystals. Effect of type and concentration of hydrophilic polymer, solv
... Show MoreThe current work discusses the removal of brilliant dyes. These dyes were Brilliant Cresyl Blue (BCB) and Brilliant Green (BG) by the use of poly acrylic acid hydrogel beads (PAA). We examined the adsorption isotherms and found that the factors preferring it are temperature and salt, shaking effects, wet PAA, (BCB) and (BG) follows Freundlich equation more than other equations. Based on the results, there is a positive correlation between adsorption of dyes (BCB and BG) and temperature (Endothermic process). We calculated the thermodynamic functions (ΔG, ΔS, and ΔH). The ion strength effects on the adsorptions at (20 °C) increased adsorption if the salt concentrations is high. We treated the kinetics outcomes based on Lagergren Equation
... Show MorePleomorphic adenoma (PA) is the most frequent benign epithelial neoplasm of salivary glands, displaying a remarkable degree of morphological variety. The aim of the study is to illustrate the clinicopathological characteristics of PA with particular emphases on epithelial cell morphology and mesenchymal elements. Materials and Methods: A total of 132 PA collected between 2002 and 2017 were recruited from Al Shahid Ghazi Al Hariri Hospital and the Department of Oral Pathology, College of Dentistry, Baghdad University, Baghdad, Iraq, and analyzed for their demographic and histopathological features. All data were analyzed using descriptive statistics. A slightly higher incidence of PA was detected in females (52.3%) compared to male subject
... Show MorePVC membrane sensor for the selective determination of Mefenamic acid (MFA) was constructed. The sensor is based on ion association of MFA with Dodecaphospho molybdic acid (PMA) and Dodeca–Tungstophosphoric acid(PTA) as ion pairs. Nitro benzene (NB) and di-butyl phthalate (DBPH) were used as plasticizing agents in PVC matrix membranes. The specification of sensor based on PMA showed a linear response of a concentration range 1.0 × 10–2 –1.0 × 10–5 M, Nernstian slopes of 17.1-18.86 mV/ decade, detection limit of 7 × 10-5 -9.5 × 10 -7M, pH range 3 – 8 , with correlation coefficients lying between 0.9992 and 0.9976, respectively. By using the ionphore based on PTA gives a concentration range of 1.0 × 10–4 –1.0 × 10–5 M,
... Show More