Background: Pit and fissure sealant have been considered an outstanding adjunct to oral health care in the decrease of occlusal caries onset and low progression. The aims of this in vitro study were to evaluate the marginal microleakage of three different types of fissure sealants (SDI, Tg and tetric N-flow) by time interval, one day and 45 days, in the presence or absence of bonding agent among maxillary and mandibular teeth. Materials and methods: Seventy two sound human maxillary and mandibular first premolar teeth were collected which were free from obvious carious lesions. The teeth were randomly divided into two main equal groups, group (1) and group (2), each group consists of (36) teeth involving equal numbers of maxillary and mandibular teeth. The first group incubated for one day, the second incubated for (45) days. Each group divided into two subgroup; one of them treated with bonding agent while the other without. Then each subgroup was treated with three different materials which were; Tg sealant (without fluoride) group (A), SDI sealant (containing fluoride) group (B) and Tetric N-flow (flowable composite) group (C). Each one consist of six teeth involving three maxillary and three mandibular. Then dye penetration tested by using methylene blue dye, then the teeth cleaned and sectioned by sectioning device and tested under microscope. Results, the results had shown that, group (C+) in both incubation periods have no microleakage (score 0), but there was an opposite effect when using bonding agent with sealant materials not containing filler particles that showed a significant increase in the microleakage rate as shown in groups (A+ and B+). The opposite effect was seen also when used sealant materials containing filler particles but without bonding agent that seen in group (C) during both incubation periods that showed significant increasing in microleakage rate. While the effect of fluoride was very clear in decreasing significantly the microleakage rate after (45) days of incubation in both groups that treated with and without bonding agent (groups B and B+). Concerning the anatomical variation, there were no significant changes in most groups regarding the microleakage rate. Conclusions: Results had shown that the microleakage can be prevented by using of flowable composite containing nanofillers that treated with bonding agent after etching of enamel with 35% phosphoric acid gel.
Chemical pollution is a very important issue that people suffer from and it often affects the nature of health of society and the future of the health of future generations. Consequently, it must be considered in order to discover suitable models and find descriptions to predict the performance of it in the forthcoming years. Chemical pollution data in Iraq take a great scope and manifold sources and kinds, which brands it as Big Data that need to be studied using novel statistical methods. The research object on using Proposed Nonparametric Procedure NP Method to develop an (OCMT) test procedure to estimate parameters of linear regression model with large size of data (Big Data) which comprises many indicators associated with chemi
... Show MoreBackground: The skin functions as a barrier to the external environment, damage to this barrier following a burn disrupts the innate immune system and increases susceptibility to bacterial infection. Objective: This study was carried out to determine the bacterial isolates and study their antimicrobial susceptibility in burned wound infections at one burn's hospital in Baghdad.Type of study:Cross-sectional study.Methods: The bacteria were identified at species level by using Analytic Profile Index (API) system and The antimicrobial susceptibility test was performed according to Kirby-Bauer (disk diffusion) technique.Results: Over a period of one year (from October 2014 to October 2015). Out of 848 patients with different degrees of burns
... Show MoreBackground : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesisMethods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and
... Show MoreIn this work, we have examined the spectral response of (p-CuAlSe2/n-Si) detector, (CAS) thin films deposited by thermal evaporation at RT with a thickness (450) nm, and annealing temperature at (473K) for 2 h. Optical transmission measurements displayed reasonably slight transmission besides higher absorbance trendy the visible region, energy gaps were observed by annealing, were found to be direct, and decreased with the effect of annealing. The extreme responsivity value arises at wavelength 459 nm, with improvement value of specific detectivity and quantum efficiency the annealing films be situated originate as greatest suitable aimed at numerous device application.
This research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.
A progressive increase in the desire for environmentally friendly lubricants by users and strict government regulations for the use of these lubricants has provided an opportunity to use plant oils as biodegradable lubricants, therefore vegetable oils have been investigated to replace oil lubricants because of their maintaining the conditions of nature (environment) properties. In this paper, the influences of the blending ratio of mustard seeds oil with commercial mineral oil (SAE40) on the tribological characteristics were investigated and compared with mineral oil using the four-ball tribotester. Mustard seeds oil was blended with mineral oil at a volumetric ratio ranging from 22.5 to 90%. All experimental works were
... Show MoreFast dissolving film can be defined as a dosage form, which when placed in the oral cavity. It will rapidly disintegrate and dissolves to release the medication for oral mucosal absorption or allow for the gastrointestinal absorption to be achieved when swallowed.
Flurbiprofen is non-steroidal anti-inflammatory agent with antipyretic and analgesic properties and can be used in low doses 8.75 mg as analgesic and anti inflammatory agent in sore throat infection. This study aims to formulate flurbiprofen as oral dissolving films, to improve the effective relief of pain with severe sore throats with little or no adverse effect.
Nine formulas were prepared using solvent-casting method, and t
... Show More