Background: Mini implant stability is primarily related to local bone density; no studies have evaluated bone density related to mini implant placement for orthodontic anchorage between different age groups in the maxilla and the mandible. The present research aims to evaluate side, gender, age, and regional differences in bone density of the alveolar bone at various orthodontic implant sites. Materials and method: Fifty three individuals who were divided into two groups according to their age into: group I (ages 16-20 years) and group II (ages 21-29 years) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 102 points (51 in the maxilla and 51 in the mandible), and mean alveolar bone density was calculated at each site in the CT axial plane. Results: No significant differences in bone density between the sides and gender were found. Generally, the bone density measurements of group I and II were not statistically different at almost most sites. The mean bone density of the alveolar cortical bone was greater in the mandible than in the maxilla and showed a progressive increase from the anterior to the posterior area, while in the maxilla the highest bone density was at the premolars region. The maxillary tuberosity was the region with lowest bone density. Cancellous bone had almost comparable densities between the mandible and the maxilla and its density was less than those of cortical sites. Conclusion: When mini implants are indicated, no gender and side differences affect the success rate regarding bone density; while age and area should be considered when selecting and placing mini implants for orthodontic anchorage.
Introduction to Medical Physics for Pharmacy Students and Medical Groups - ISBNiraq.org
We found that 4,5- diphenyl- 3(2- propynyl) thio- 1??-triazole [1? forms a complex with Pd (11) ion of ratio 1:1 which absorbs light in CH2CI2 at 400 nm, and 4,5- diphenyl- 3(2- propenyl) thio- 1,2,4- triazole [II] forms complexes with Pd (II) ion of ratio 1:1 which absorbs light at 390 nm, and of ratio 2:1 which absorbs light at 435 nm. On the other hand, we found that the new derivative 4- phenyl- 5( p- amino phenyl) -3- mercapto- 1,2,4- triazole ?111? forms complexes with Cu (II) ion of the ratio 1:1 which absorbs light at 380 nm, with Ni (II) ion of the ratio 3:1 which absorbs light at 358 nm; and with Co (11) ion of the ratio 3.2:1 which absorbs light at 588 nm. The ratio of the complexes were determined by measuring the electronic spe
... Show MoreDensity Functional Theory at the generalized-gradient approximation level coupled with large unit cell method is used to simulate the electronic structure of (II-VI) zinc-blende cadmium sulfide nanocrystals that have dimensions 2-2.5 nm. The calculated properties include lattice constant, conduction and valence bands width, energy of the highest occupied orbital, energy of the lowest unoccupied orbital, energy gap, density of states etc. Results show that lattice constant and energy gap converge to definite values. However, highest occupied orbital, lowest unoccupied orbital fluctuates indefinitely depending on the shape of the nanocrystal.
Eprospective study undertaken between January 2007 and January 2011, 58 consecutive cases with compound tibial shaft fractures. All fractures were stabilized by external fixator device AO/ASIF type after failed the manipulation under anesthesia (MUA) to restore the osseous alignment. In 32 patients cancellous bone graft were used from the upper part of the tibia to enhance healing process, all these patients were followed for an average of 8–12 months. Our findings showed that stabilization of the fracture shaft tibia by external fixation with cancellous bone graft had significantly better result, than external fixation alone. We conclude that unilateral, uniplanar external fixation with early bone grafting from upper part of the tibia is
... Show MoreAge, hypertension, and diabetes can cause significant alterations in arterial structure and function, including changes in lumen diameter (LD), intimal-medial thickness (IMT), flow velocities, and arterial compliance. These are also considered risk markers of atherosclerosis and cerebrovascular disease. A difference between right and left carotid artery blood flow and IMT has been reported by some researchers, and a difference in the incidence of nonlacunar stroke has been reported between the right and left brain hemispheres. The aim of this study was to determine whether there are differences between the right and left common carotid arteries and internal carotid arteries in patient
The integration of decision-making will lead to the robust of its decisions, and then determination optimum inventory level to the required materials to produce and reduce the total cost by the cooperation of purchasing department with inventory department and also with other company,s departments. Two models are suggested to determine Optimum Inventory Level (OIL), the first model (OIL-model 1) assumed that the inventory level for materials quantities equal to the required materials, while the second model (OIL-model 2) assumed that the inventory level for materials quantities more than the required materials for the next period. &nb
... Show More