Background: Mini implant stability is primarily related to local bone density; no studies have evaluated bone density related to mini implant placement for orthodontic anchorage between different age groups in the maxilla and the mandible. The present research aims to evaluate side, gender, age, and regional differences in bone density of the alveolar bone at various orthodontic implant sites. Materials and method: Fifty three individuals who were divided into two groups according to their age into: group I (ages 16-20 years) and group II (ages 21-29 years) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 102 points (51 in the maxilla and 51 in the mandible), and mean alveolar bone density was calculated at each site in the CT axial plane. Results: No significant differences in bone density between the sides and gender were found. Generally, the bone density measurements of group I and II were not statistically different at almost most sites. The mean bone density of the alveolar cortical bone was greater in the mandible than in the maxilla and showed a progressive increase from the anterior to the posterior area, while in the maxilla the highest bone density was at the premolars region. The maxillary tuberosity was the region with lowest bone density. Cancellous bone had almost comparable densities between the mandible and the maxilla and its density was less than those of cortical sites. Conclusion: When mini implants are indicated, no gender and side differences affect the success rate regarding bone density; while age and area should be considered when selecting and placing mini implants for orthodontic anchorage.
In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.
The concept of TQM is based on one of the concepts that combine administrative and innovative methods. The aim of the research is to demonstrate the dimensions of TQM in enhancing the satisfaction of the taxpayers through a survey of a sample of officials in the General Authority for Taxation and 50 officials. In the collection of data and information, and the results were analyzed using the SPSS program to find the most important compounds and factors in he method of analysis.
The research problem was represented by the non-application of the General Authority for Taxation to the entrances and modern practices in the administrative work. The results of some of the complications that accompany the tax accounting process, which af
... Show MoreIn this study, the amounts of activity concentrations of naturally occurring in 10 soil samples of the Tigris river and surrounding areas collected from deferent city of Baghdad have been investigated. Tigris river is an important water source for irrigation and drinking in Iraq. This study was done during 2018 in Protection Center of the Iraqi Ministry of Health and Environment using a high purity germanium detector. The resolution of (HPGe) at 2keV and 30% efficiency. The results of soil sample obtained showed that the effective activity concentration of 40K are ranged from 181.4 Bq/kg in sample S6 to 286.4 Bq/kg in S7. For Raeq values are ranged from 6 Bq/m3 in sample S5 to 17 Bq/m3 in sample S3. The obtained data revealed that the me
... Show MoreA rapid high sensitive and inexpensive economic method has been developed for the Determination of phenoxazine by using molecular spectrophotometry. The method is based on the oxidation of phenoxazine by potassium (meta)periodate in acidic medium. The oxidation conditions were selected to enhance the sensitivity and the stability of the pink colored species which shows an absorption maximum at 530 nm. The Beer’s law was obeyed for phenoxazine concentration range from 1 to 6 µg mL-1 with 0.003 µg mL-1 detection limit and provided variation coefficients between 0.4 to 1.7 %. This method was successfully applied for the determination of phenoxazine in aqueous samples
Background: Disc battery ingestion is a common
serious problem in Iraq. It increase in the last years
because of the increase in number of electronic toys
that uses these batteries. These batteries contains
many types of irritant chemicals that increases the
risk of it's ingestion.
Methods:We reviewed the medical records of
children aged between 1year and 7 years
old admitted to Surgical Specialty Hospital/Baghdad
Medical City due to disc battery ingestion from
January 2007 through December 2010). The diagnosis
of disc battery ingestion was based upon history,
clinical symptoms, and results of imaging studies.
The clinical data reviewed included sex, age, clinical
manifestation and duration of sy
We studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show MoreThe electron correlation effect for inter-shell have been analysed in terms of Fermi hole and partial Fermi hole for Li-atom in the excited states (1s2 3p) and (1s2 3d) using Hartree-Fock approximation (HF). Fermi hole Δf(r12) and partial Fermi hole Δg(r12 ,r1) were determined in position space. Each plot of the physical properties in this work is normalized to unity. The calculation was performed using Mathcad 14 program.