Background: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different brand configurations: closed loop and open (short filament) chains under effect of time at (zero time, 24hr., 7, 14 , 21 and 28 days) in artificial saliva. Results: Statistical analysis showed that there was a highly significant difference in the mean percentage force decay for the three different mechanisms (P? 0.001).For all the three types, the 6-3 mechanism had the smallest mean percentage force decay. There was a highly significant difference in the mean percentage force decay for the different types (P? 0.001). For all three mechanisms, extreme silver elastomeric chains had the smallest percentage force decay while maximum silver elastomeric chains had the highest percentage force decay. Conclusion: This study illustrated that for all the three types of elastomeric chains, the (6-3) mechanism had the smallest mean percentage force decay. This finding suggests that it may be most efficient to retract a canine utilizing elastomeric chain directly from the molar hook to the canine bracket. The chain loop mechanism may not be indicated for space closure in vivo due to the excessive physiological force values involved with this mechanism.
Background: The need of the patient for a more reasonable esthetic orthodontic intervention has risen nowadays. Thus, orthodontists make use of esthetic orthodontic materials like brackets, ligature elastics, and arch wires. The esthetic brackets come as different forms of materials, such as ceramic brackets, which have their stainability remaining as the most important consideration for the patients and the orthodontists. This study aimed to compare the staining effects of various staining materials, including black tea, cigarette smoke and Pepsi, as well as the time effect on the color stability of sapphire ceramic brackets bonded with three kinds of light cure orthodontic adhesives: Transbond, Resilience and Enlight. Materials and Met
... Show MoreThe study aims to elucidation Difference distribution of the labor force by occupation in Sulaymaniyah governorate for the year 2013 by result field study to governorate and explain different Spatially for labor force by career. and The study reaches That Executive staff and Scribes and who join their high ratio from Total the labor force And the second Grade to Specialists and Technicians and who join their While Occupied career Production workers and who join their and Operators Transport Equipment and Engaged the third Grade from the total labor force and Continued Height in career Executive staff and who join their on the male labor force too . while Production workers in second Grade for male labor force , while the female labor for
... Show MoreThe aim of this paper is to construct cyclic subgroups of the projective general linear group over from the companion matrix, and then form caps of various degrees in . Geometric properties of these caps as secant distributions and index distributions are given and determined if they are complete. Also, partitioned of into disjoint lines is discussed.
In this paper, an adaptive integral Sliding Mode Control (SMC) is employed to control the speed of Three-Phase Induction Motor. The strategy used is the field oriented control as ac drive system. The SMC is used to estimate the frequency that required to generates three phase voltage of Space Vector Pulse Width Modulation (SVPWM) invertor . When the SMC is used with current controller, the quadratic component of stator current is estimated by the controller. Instead of using current controller, this paper proposed estimating the frequency of stator voltage since that the slip speed is function of the quadratic current . The simulation results of using the SMC showed that a good dynamic response can be obtained under load
... Show MoreBackground: Impacted teeth are frequent problem and one of the most affected teeth is the maxillary canine. The early diagnosis of impacted canines by radiographic evaluation is imperative. The aim of this study was to determine the prevalence of impacted maxillary canines in patients attending the Oral diagnosis and Radiology clinic in College of Dentistry, University of Al-Basrah. Materials and Methods: 1280 patients attending the Oral Diagnosis and Radiology clinic in College of Dentistry University of Al-Basrah, between October 2013 and March 2015 were examined for the study. The age of the patients ranged from 15 to 55 years, with a mean age of 22.2 years. Results: The prevalence for maxillary impacted canines in all the cases was fo
... Show MoreThe main factors that make it possible to get the corrosion of reinforcing steel in concrete are chloride ions and the absorption of carbon dioxide from the environment, and each of them works with a mechanism which destroys the stable immunity of rebar in the concrete. In this work the effect of carbon dioxide content in the artificial concrete solution on the corrosion behavior of carbon steel reinforcing bar (CSRB) was studied, potentiostatically using CO2 stream gas at 6 level of concentrations; 0.03 to 2.0 weight percent, and the effect of rising electrolyte temperature was also followed in the range 20 to 50ᴼ C. Tafel plots and cyclic polarization procedures were obeyed to investigate the c
... Show MoreAbstract Objectives: Malocclusion was and remains one of the most common problems which affects the psyche and social status of the individual, so the estimation of the malocclusion severity and needs a percentage of orthodontic treatment of Iraqi patients is the aim of this study. Method: A randomly selected 150 pairs of study models (48 male and 102 female) were involved in this study for patients attending an orthodontic clinic at College of Dentistry/ University of Baghdad seeking for treatment. The DAI scores were collected according to WHO guidelines directly from the study model with a digital caliper, score was calculated using the regression equation of 10 occlusal traits. The dental casts were classified into four groups to determ
... Show MoreChoosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show MoreBackground: The aim of this study was to evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic adhesive systems after exposure to aging media (water storage and acid challenge). Materials and methods: Eighty human upper premolar teeth were extracted for orthodontic purposes and randomly divided into two groups (40 teeth each): the first group in which the bonded teeth were stored in distilled water for 30 days at 37°C, and the second group in which the bonded teeth were subjected to acid challenge. Each group was further subdivided into four subgroups (10 teeth each) according to the type of adhesive system that would be bonded to metal brackets: either non-fluoride releasing adhesive (NFRA),
... Show MoreABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of
... Show More