Background: Information concerning the maximum bite force in human population is important to clinical orthodontics. Additionally, the influence of bite force on the vertical stability of any treatment result is important. The new position of the dentition should be compatible with the dynamics of the muscular and occlusal forces in all planes. This study was conducted to 1) to measure and compare maximum bite force, body height and weight among normal occlusion and malocclusion groups (cl I,cl II,cl III) in both gender 2) to evaluate the correlation between bite force and craniofacial morphology, body height and weight. Materials and Methods: The sample consists of 100 Iraqi adult subjects aged 18-25 years. It was classified in to four groups: cl I normal occlusion, cl I malocclusion, cl II malocclusion, and cl III malocclusion according to(skeletal) the value of ANB angle and (dental)the Angle classification. Each group consist of 25 (13 male, 12 female), Maximum bite force was measured by a digital device (GM10, Naganokeiki, Japan) by putting the sensor part of occlusal force meter on first molar region, body height and weight were measured by using the Length and Weight Measuring Standard (Tanita, 2008) and craniofacial measurements were achieved by analysis of lateral cephalometric radiograph Results: The highest mean value of maximum bite force was found in normal occlusion followed by class II malocclusion and then class I malocclusion and the lowest value was found in class III malocclusion, class I skeletal relationship (cl I normal occlusion & cl I malocclusion group) had larger values of body weight when compared with skeletal class II& class III .Regarding the gender, mean values of maximum bite force and body height are higher in male than female in normal occlusion and malocclusion groups, There is a positive correlation between maximum bite force and body height and weight in normal occlusion and class I malocclusion ,there is a positive correlation between maximum bite force and palatal plane, Ramus plane, mandibular plane, posterior facial height, cranial base, dentoalveolar height, while there is a negative correlation with anterior facial height, Gonial angle, SN-Mp?,PP-MP&SN-PP? angles. Conclusion: The normal occlusion group had larger values of bite force than malocclusion group,the maximum bite force, body height is gender related, larger body build up was usually associated with larger bite force in class I skeletal relationship, Individuals with characteristics of larger maxilla ,larger mandible, larger cranial base ,short anterior facial height long posterior facial height, flat mandibular plane had the largest value of bite force.
This study showed that the lens in baloot muluki fish Chondrostoma regium is transparent, spherical shape, and solid in textures, while in the tree frog Hyla arborea savignyi, freshwater turtles Clemmys caspia caspia, white–eared bulbul Pycnonotus leucotis and brown rat Rattus norvegicus are transparent, soft and biconvex, it is very soft in white–eared bulbul. There are many significant differences have been recorded between the average weight lens and the total concentration of the protein in the lens all studied animals. Electrical migration process for lens proteins showed that there is one bundle of crystalline –? and one bundle also crystalline–? in all studied species, either crystalline–? may represent one bundle character
... Show MoreBackground: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl
... Show MoreA method was developed that offers a rapid, simple and accurate technique for the determination of chlorophenols at trace levels in aqueous samples with very limited volumes of organic solvents. These compounds were acetylated, then preliminarily extracted with n-hexane. The enriched chlorophenols were directly analyzed using gas chromatography with an electron-capture detector. The detection limits were in the range of 0.001–0.005 mg/L, except for 2-chlorophenol, which was always above 0.013 mg/L. Relative standard deviation for the spiked water samples ranged from 2.2 to 6.1%, while relative recoveries were in the range of 67.1 to 101.3%.
Mixed convection heat transfer to air inside an enclosure is investigated experimentally. The bottom wall of the enclosure is maintained at higher temperature than that of the top wall which keeps in oscillation motion, whereas the left and right walls are well insulated. The differential temperature of the bottom and top walls changed several times in order to accurately characterize the temperature distribution over a considerable range of Richardson number. Adjustable aspect ratio box was built as a test rig to determine the effects of Richardson number and aspect ratio on the flow behavior of the air inside the enclosure. The flow fields and the average Nusselt number profiles were presented in this wo
... Show MoreBackground: The etiology of Systemic lupus erythematosus seems to be multifactorial including environmental as well as genetic factors. The genetic predisposition was supported by the occurrence of Systemic lupus erythematosus in more than one member of a family as well as in identical twins.
Aim of the study: To determine the human leukocyte antigen typing class I (A and B) in patients with Systemic Lupus Erythematousus disease.
Methods: Patients group consisted of 44 Iraqi Arab Muslims patients with Systemic lupus erythematosus disease who presented to Baghdad Medical City from January 2010 to January 2012 from Baghdad Province. The second control group consisted from 80 Iraqi Arab Muslims volunteers from hospital employees and t
In this paper, we established a mathematical model of an SI1I2R epidemic disease with saturated incidence and general recovery functions of the first disease I1. Considering the basic reproduction number, we obtained conditions for both disease-free and co-existing cases. The equilibrium points local stability is verified by using the Routh-Hurwitz criterion, while for the global stability, we used a suitable Lyapunov function to analyze the endemic spread of the positive equilibrium point. Moreover, we carried out the local bifurcation around both equilibrium points (disease-free and co-existing), where we obtained that the disease-free equilibrium point undergoes a transcritical bifurcation. We conduct numerical simulations that suppo
... Show MoreCost estimation is considered one of the important tasks in the construction projects management. The precise estimation of the construction cost affect on the success and quality of a construction project. Elemental estimation is considered a very important stage to the project team because it represents one of the key project elements. It helps in formulating the basis to strategies and execution plans for construction and engineering. Elemental estimation, which in the early stage, estimates the construction costs depending on . minimum details of the project so that it gives an indication for the initial design stage of a project. This paper studies the factors that affect the elemental cost estimation as well as the rela
... Show MoreBackground: Nickel-titanium (NiTi) archwires have become increasingly popular because of their ability to release constant light forces, which are especially useful during initial alignment and leveling phase. The aim of the present study was to investigate and compare the load–deflection characteristics of four commercially available NiTi archwires. Materials and methods: 200 NiTi 0.014, 0.016, 0.018, 0.016x0.022 and 0.019x0.025-inch nickel–titanium archwires from four different manufacturers (3M, Ortho Technology, Jiscop and Astar) were tested. The load-deflection properties of these archwires were evaluated by a full arch bending test in both palatal and gingival directionsat 37°C temperature using a universal material t
... Show MoreBackground: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show More