Background: Chronic periodontitis defined as “an infectious inflammatory disease within supporting tissues of the teeth, progressive attachment loss and bone loss". Aggressive periodontitis is rare which in most cases manifest themselves clinically during youth. It characterized by rapid rate of disease progression .Pro-inflammatory chemokines organized inflammatory responses. Granulocyte chemotactic protein 2 is involved in neutrophil gathering and movement. The purpose of the study is to detect serum of Granulocyte Chemotactic Protein 2 and correlate to periodontal condition in patients with chronic periodontitis, Aggressive periodontitis and Healthy Control subjects and measurement the count of neutrophils for the studied groups. Subjects and methods: Eighty four male and female were enrolled in this study .They were divided into three groups (18) patients with Aggressive periodontitis with age range (20-45) years, (33) chronic periodontitis patients and (33) Healthy control with an age range (30-50). Clinical periodontal parameters were recorded for each group. The concentration of granulocyte chemotactic protein- 2 in serum was quantified by a high-sensitivity enzyme linked immunosorbent assay. Blood neutrophils count were detect for five subjects from each group using light microscope Result: ANOVA analysis revealed high significant differences in Granulocyte chemotactic protein 2 means between aggressive, chronic and controls. Neutrophils count in aggressive periodontitis is higher than chronic and controls .No significant difference in neutrophils count between aggressive and chronic periodontitis, while significant difference when correlate them with controls Conclusion The concentration of granulocyte chemotactic protein 2 increased with the increase in severity of periodontitis. Higher neutrophils count was found in aggressive periodontitis than chronic and controls. As higher granulocyte chemotactic protein 2 that chemoattract more neutrophils recruitment to the site of inflammation
Fibroblast growth factor-23, play an important role in atherosclerosis, endothelial dysfunction and vascular calcification. Sevelamer can improve vascular calcification, serum uric acid, low-density lipoprotein-cholesterol and Fibroblast growth factor-23. Aim of study Assessment the effect of sevelamer as phosphate binder against calcium carbonate on Fibroblast growth factor-23. Methods A prospective open-labelled study that included patients on hemodialysis. A total of 72 patients were screened, only 53 patients completed the 10 week period. Adults patients with serum phosphate as> 5.5 mg/dl were included. There were Group1: Includes 28 patients (19 males and 9 females receiving sevelamer carbonate (Renvela) tablet. Group 2: Include 25pati
... Show MoreThe study objective was to conduct Pharmacoeconomics study (cost-effective analysis) between infliximab reference (Remicade) and its biosimilar (Remsima) in patients with rheumatoid arthritis (RA) in Iraqi hospitals.
This is a retrospective multicenter pharmacoeconomic analysis conducted at two large teaching governmental hospitals in Baghdad, Iraq which provided infliximab to patients with RA. Data were collected from patient’s medical records and face-to-face interviews with the patients from December 2021 to April 2022.
The study included 57 patients with rheumatoid arthritis (RA). The patients were categorized into two groups according to the type of infliximab they received over 30 weeks: 27 patients received
... Show MoreIrinotecan (CPT-11) is a semisynthetic derivative of the antineoplastic agent camptothecin used in a wide range as an anti-cancer agent in many solid tumors because of its cytotoxic effect through the interaction with the topoisomerase I enzyme. The major limiting factors for irinotecan treatment are its association with potentially life-threatening toxicities including neutropenia and acute or delayed-type diarrhea, results from distinct interindividual and interethnic variability due to gene polymorphism.
This is a cross sectional pharmacogentics study was conducted on 25 cancer patients to estimate the prevalence of UGT1A1*93 and ABCC5 allele single nucleotide polymorphism (SNP) in Iraqi cancer patients treated with irinotecan
... Show MoreBreast cancer is the most common malignancy in female and the most registered cause of women’s mortality worldwide. BI-RADS 4 breast lesions are associated with an exceptionally high rate of benign breast pathology and breast cancer, so BI-RADS 4 is subdivided into 4A, 4B and 4C to standardize the risk estimation of breast lesions. The aim of the study: to evaluate the correlation between BI-RADS 4 subdivisions 4A, 4B & 4C and the categories of reporting FNA cytology results. A case series study was conducted in the Oncology Teaching Hospital in Baghdad from September 2018 to September 2019. Included patients had suspicious breast findings and given BI-RADS 4 (4A, 4B, or 4C) in the radiological report accordingly. Fine needle aspirati
... Show MoreBackground: Hair loss is a common distressing disease and challenging problem for many dermatologist. Telogen effluvium is the most common hair loss disease in which nutritional deficiencies may precipitate the disease through their effect on hair structure and growth.
Study Aim : Validating role of serum ferritin level and body mass index in Chronic Telogen Effluvium and analyzing association between these factors with socioeconomic, demographic, gynecological factors and weight loss effect. Establishing a nutritional preventive advice to improve treatment successfulness and decrease the disease occurrence.
... Show More
Detecting and subtracting the Motion objects from backgrounds is one of the most important areas. The development of cameras and their widespread use in most areas of security, surveillance, and others made face this problem. The difficulty of this area is unstable in the classification of the pixels (foreground or background). This paper proposed a suggested background subtraction algorithm based on the histogram. The classification threshold is adaptively calculated according to many tests. The performance of the proposed algorithms was compared with state-of-the-art methods in complex dynamic scenes.
A nonlinear filter for smoothing color and gray images
corrupted by Gaussian noise is presented in this paper. The proposed
filter designed to reduce the noise in the R,G, and B bands of the
color images and preserving the edges. This filter applied in order to
prepare images for further processing such as edge detection and
image segmentation.
The results of computer simulations show that the proposed
filter gave satisfactory results when compared with the results of
conventional filters such as Gaussian low pass filter and median filter
by using Cross Correlation Coefficient (ccc) criteria.
Atmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geom
... Show MoreI
In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2)
... Show More