Background: Tooth wear is one of the most concerning problems of the current dental practice especially among older subjects. The aim of this study is to determine the severity of tooth wear and its relation with selected salivary variables (salivary pH and vitamin C level) among a group of older adults in Mosul city/Iraq. Materials and methods: All subjects (30 subjects) of both gender tookpart in the current study; sixteen of them were older adults (55-65 years) and compared with fourteen middle-aged adults (30-40 years) at Textile factory in Mosul city/Iraq. Unstimulated salivary samples were collected and salivary pH was immediately measured. Salivary vitamin C level was determined colormetrically. Severity of tooth wear was determined according to Hansson and Nilner (1975) classification. Results: Results showed that all severity scores of tooth wear revealed higher percentage among older adults than middle-aged adults. Also all tooth segment types revealed higher percentage of tooth wear among older adults than middle-aged adults. Moreover regarding the highest score of tooth wear by subjects, higher percentage of tooth wear was found among older adults than middle-aged adults. Concerning the total sample results disclosed that wear of enamel only revealed higher percentage than one or more teeth worn into dentine and one or more teeth worn up to 1/3 of the crown. Also in the total sample the incisor region showed higher percentage of tooth wear while the least tooth wear percentage was found in the molar region. In both age groups no significant correlations were found between salivary pH and vitamin C with the highest score of tooth wear. Conclusion: Tooth wear is more severe among older subjects. Further study is needed with larger sample size and more precise index that measure the etiology of tooth wear.
The increased applications of technology in the field of architecture, especially digital technology and aspects of automation, have made a major impact on various aspects of local architecture, especially the traditional ones. As these technologies have succeeded in integrating many technological applications in many traditional and heritage buildings and taking them to more complex uses. And included in it characteristics that were not contained, therefore the research problem was concentrated in the absence of a holistic view of the role of the aspects of automation as a technological and design effect and its mutual effects on traditional buildings (especially the traditional Bagh
The current research deals with the argument of delusion and interpretation in the direction structure and its reflected impact in the reception activity and the amount of conceptual displacement it is subjected to in an aesthetic approach to abstract conceptual definitions of the reception activity , by the effect of this dialectic in the direction structure, which can be summed up by the following question: (What are the characteristics of the direction structure of the imaginary and what is the argument of interpretation in the theatre reception activity?) in order to stand on the aesthetic framework and conceptual definition of the direction structure in the controversy of interpretation and imagination, and its impact on the concept
... Show MoreThis study proposes a mathematical approach and numerical experiment for a simple solution of cardiac blood flow to the heart's blood vessels. A mathematical model of human blood flow through arterial branches was studied and calculated using the Navier-Stokes partial differential equation with finite element analysis (FEA) approach. Furthermore, FEA is applied to the steady flow of two-dimensional viscous liquids through different geometries. The validity of the computational method is determined by comparing numerical experiments with the results of the analysis of different functions. Numerical analysis showed that the highest blood flow velocity of 1.22 cm/s occurred in the center of the vessel which tends to be laminar and is influe
... Show MoreBackground: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc
... Show MoreThere is no doubt that each of the arts has a material from which the aesthetic achievement is built, so the researcher found that the art of theater, especially the show, whose artistic achievement is based on the body of the actor who emits the formal language (body language), is the focus of interest and active presence, because the body possesses its spiritual qualities that made him and the ability to The formation of things by (his body language), so the researcher studied this theatrical phenomenon and divided it into four chapters. In the first chapter, the research problem included the following question: (Is there a phenomenon of body language in the contemporary theatrical show "Imagine that" as a model) so It is of cognitive
... Show More