Preferred Language
Articles
/
jbcd-1441
Comparison of Shear Bond Strength of Three Different Brackets Bonded on Zirconium Surfaces (In Vitro Study)
...Show More Authors

Background: With the increased in the demands of adult orthodontics, the challenge of direct bonding to non-enamel surface (zirconium) had been increased. The present study was carried out to compare the shear bond strength of three different brackets (stainless steel, sapphire and composite) bonded to zirconium surface and study the mode of bond failure. Materials and methods: The sample was comprised of 30 models (8mm *6mm*1.5mm) of full contour zirconium veneers. They were divided into three groups according to the brackets type; all samples were treated first by sandblast with aluminum oxide particle 50 µm then coated by z-prime plus primer. A central incisor bracket of each group was bonded to the prepared zirconium surface with light cure adhesive resin (Transbond TM XT, 3M Unitek, USA). Shear bond strength was measured by using Tinius Olsen universal testing machine at crosshead speed of 0.5\min. After debonding, each bracket and zirconium surface were examined using magnifying lens and adhesive remnant index was recorded. The difference in shear bond strength between main groups was analyzed by using ANOVA at p≤0.05. Results: The results revealed high significant difference among all tested groups and the highest value was for sapphire brackets (7.49±1.45 Mpa) of all groups followed by stainless steel brackets (6.46±1.43Mpa) and composite brackets had the least value (4.35±0.72). Non-significant difference in the site of bond failure among all groups of brackets and zirconium-adhesive interface failure (score III) was the predominant. Conclusion: the new zirconium prime plus primer can be successfully used in bonding stainless steel and sapphire brackets to zirconium surface.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation, In-vitro, and Ex-vivo Evaluation of Ondansetron Loaded Invasomes for Transdermal Delivery
...Show More Authors

Invasomes are newly developed types of nanovesicles. A vesicular drug delivery system is considered one of the approaches for transdermal delivery to enhance permeation and improve drug bioavailability. Ondansetron is a serotonin receptor antagonist used for treating vomiting associated with different clinical cases. The study aimed to prepare invasomal dispersions for improving permeation of ondansetron across the skin with a controlled release pattern. Twenty-seven formulas of ondansetron-loaded invasomes were prepared by a modified mechanical dispersion method. These formulas were optimized by studying the effect of variables on entrapment efficiency. Vesicle size, polydispersity, zeta potential, in-vitro release and ex-vivo perm

... Show More
Preview PDF
Scopus (8)
Crossref (8)
Scopus Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Effect of Recirculation Ratio on the Uniformity Flow in a High Area Ratio of Outlets Pipe at Different Entrance flow rates
...Show More Authors

The uniform flow distrbiution in the multi-outlets pipe highly depends on the several parameters act togather. Therefor, there is no general method to achieve this goal. The  goal of this study is to investigate the proposed approach that can provide significant relief of the maldistribution. The method is based on re-circulating portion of flow from the end of the header to reduce pressure at this region . The physical model consists of main manifold with uniform longitudinal section having diameter of 152.4 mm (6 in), five laterals with diameter of 76.2 mm (3 in), and spacing of 300 mm. At first, The experiment is carried out with conventional manifold, which is a closed-end. Then, small amount of water is allowed

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 01 2021
Journal Name
International Journal Of Drug Delivery Technology
Formulation and In-vitro Evaluation of Thermosensitive Ciprofloxacin HCL In-situ Gel for Local Nasal Infection
...Show More Authors

Scopus (9)
Scopus
Publication Date
Sun Jun 21 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation, in vitro and ex-vivo Evaluation of Mirtazapine Nanosuspension and Nanoparticles Incorporated in Orodispersible Tablets
...Show More Authors

          The objective of the present investigation was to enhance the solubility of practically insoluble mirtazapine by preparing nanosuspension, prepared by using solvent anti solvent technology. Mirtazapine is practically insoluble in water which act as antidepressant .It was prepared as nano particles in order to improve its solubility and dissolution rate. Twenty formulas were prepared and different stabilizing agents were used with different concentrations such as poly vinyl pyrrolidone (PVPK-90), poly vinyl alcohol (PVA), poloxamer 188 and poloxamer 407. The ratios of drug to stabilizers used to prepare the nanoparticles were 1: 1 and 1:2. The prepared nanoparticles were evaluated for

... Show More
View Publication Preview PDF
Scopus (24)
Crossref (12)
Scopus Crossref
Publication Date
Thu Jul 04 2024
Journal Name
Pharmaceutics
Formulation Development of Meloxicam Binary Ethosomal Hydrogel for Topical Delivery: In Vitro and In Vivo Assessment
...Show More Authors

Abstract: The article aimed to formulate an MLX binary ethosome hydrogel for topical delivery to escalate MLX solubility, facilitate dermal permeation, avoid systemic adverse events, and compare the permeation flux and efficacy with the classical type. MLX ethosomes were prepared using the hot method according to the Box–Behnken experimental design. The formulation was implemented according to 16 design formulas with four center points. Independent variables were (soya lecithin, ethanol, and propylene glycol concentrations) and dependent variables (vesicle size, dispersity index, encapsulation efficiency, and zeta potential). The design suggested the optimized formula (MLX−Ethos−OF) with the highest desirability to perform the

... Show More
Preview PDF
Scopus (9)
Scopus
Publication Date
Fri Dec 07 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Phytochemical Investigation of Corchorus olitorius L. Leaves Cultivated in Iraq and it’s In Vitro Antiviral Activity
...Show More Authors

The aim of our study was to investigate the antiviral activity of the Corchorus olitorius family Tiliaceae cultivated in Iraq against measles virus, and to demonstrate an overview about chemical constituents and pharmacological activity of Corchorus olitorius L.

About150 gm Leaves of Corchorus. olitorius were defatted by maceration in hexane for 24 hrs. The defatted plant materials were subjected for extraction after filtration using Soxhlet apparatus, with aqueous methanol 85% as a solvent extraction for 24 hours, the extract was filtered, and the solvent was evaporated under reduced pressure using a rotary evaporator to get a dry extract of about 12 gm. About 4 gm from the residue was suspended in 100

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Al-kindy College Medical Journal
Ultrasound of the Rotator Cuff: A Comparison of Ultrasonographic and Physical Examination Finding in SeventyCases
...Show More Authors

Background : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome. Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ultrasonogr

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Safety Profile of Single Daily Dose of Aminoglycosides in Comparison with Multiple Daily Dose
...Show More Authors

To overcome  the  problems  which  associated  with  the standard  multiple  daily  doses (MDD)

of aminoglycosides (AGs) like high incidence of toxicity(nephrotoxicity, ototoxicity)(5-25%) and high cost, an alternative approach was developed which was single daily dose (SDD).This new regimen was designed to maximize bacterial killing by optimizing the peak concentration/minimum inhibitory concentration(MIC)ratio and to reduce the potential for toxicity. The study includes 75 patients selected randomly, 50 of them received SDD regimen of age range of 17-79 years and the remaining received MDD regimen of age range of 13-71 years. The study was designed to evaluate the safety of SDD regim

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2024
Journal Name
Journal Of Obstetrics Gynecology And Cancer Research
Comparison of Levels of Activin A and Follistatin in Ectopic Pregnancies and Missed Abortions Patients
...Show More Authors

Scopus
Publication Date
Thu May 31 2012
Journal Name
Journal Of Baghdad College Dentistry
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill

... Show More