Background: Proper cleaning and shaping of the whole root canal space have been recognized as a real challenge, particularly in oval-shaped canals.This in vitro study was conducted to evaluate and compare the efficiency of different instrumentation systems in removing of dentin debris at three thirds of oval-shaped root canals and to compare the percentage of remaining dentin debris among the three thirds for each instrumentation system. Materials and methods: Fifty freshly extracted human mandibular molars with single straight oval-shaped distal root canals were randomly divided into five groups of ten teeth each. Group One: instrumentation with ProTaper Universal hand instruments, Group Two: instrumentation with ProTaper Universal rotary instruments, Group Three: instrumentation with Revo-Srotary instruments, Group Four: instrumentation withTwisted rotary files and Group Five: instrumentation with Self-Adjusting Files (SAF). Sodium hypochlorite (3%) was used as an irrigant for all groups. After canals preparation, the roots were split longitudinally and photographed with a professional digital camera. The images of root sections were then magnified to 100x and the percentage of remaining dentin debris calculated for the apical, middle and coronal thirds by dividing the pixels occupied by debris at each third by the total pixels representing the entire area of the canal using Adobe Photoshop CS6. Data were analyzed statistically by ANOVA and LSD at 1% and 5% significant levels. Results: Both ProTaper hand and ProTaper rotary files resulted in significantly cleaner canals than Revo-S and Twisted rotary files at the middle and coronal thirds. The Self-Adjusting Files produced significantly cleaner canals at the three thirds than all the other groups. The coronal and middle thirds showed a greater amount of remaining dentin debris than the apical third for all groups except a non-significant difference found between the apical and middle thirds in SAF group. Conclusion: The Self-Adjusting Files allowed more efficient cleaning of oval-shaped root canals than hand and rotary instruments
EMS in accordance with ISO 14001: 2015 is considered an entry point to reduce environmental impacts, especially the effects resulting from the oil industry, which is the main source of environmental pollution and waste of natural resources, since the second revision of the standard took place in September 2015. The problem of the research was manifested in the weakness in understanding the correct guidelines that must be followed in order to obtain and maintain the standard. The purpose of this research was to give a general picture of what is behind ISO14001:2015 and how it is possible to create a comprehensive base for understanding its application by seeking the gap between the actually achieved reality, standards requirements
... Show MoreThe compound [K1] was synthesized from the reaction of dichloromethane with linear alkyl benzene (Lab9) using ethanol as a solvent, and from(chloro methyl)-4-nonylbenzene) [K1] it was possible to synthesize the compound Z(4-(nonan-3-yl)phenyl) methane amine) [K2] containing the amine group by synthesized from [K2] reaction with appropriate phenolic aldehydes and using Ethanol as a solvent in the preparation of vinyl chloride4-(((4-nonylbenzyl)imino)methyl)phenol-4-(((4-nonylbenzyl)imino methyl)benzene-1,3diol) [K3-K4] bases has been used. Preparation of a number of Phenolic polymers4-(2- hydroxy-3.5-dimethylbenzyl)-2-methyl-6-(((4-4-(2hyroxy-3, 5-dimethylbenzyl)-2-methyl-6(((4 nonylbenzyl) imino) methyl) benzene-phenolnonylbenzyl) imino) me
... Show MoreBackground: Thermocycling simulates the temperature dynamics in the oral environment. This in vitro study done to measure and compare the effect of thermocycling on the shear bond strength of stainless steel and sapphire brackets bonded to human enamel teeth using light cured orthodontic adhesive and debonded at various time, and to measure adhesive remnant index after debonding. Materials and Methods: one-hundred-twenty extracted upper first premolars for orthodontic reason were used in this study; depending on weather thermocycled or not, the sample was divided into two main groups, then within each group 30 teeth were used for stainless-steel brackets (Bionic®) and for sapphire brackets (Pure®). Both groups were subdivided into three
... Show MoreThe study of the dynamic behavior of packed distillation column was studied by frequency response analysis using Matlab program. A packed distillation column (80 mm diameter) (2000 mm height) filled with glass packing (Raschig Rings 10mm), packing height (1500 mm) has been modified for separation of methanol-water mixture (60 vol%). The column dynamic behavior was studied experimentally under different step changes in, feed rate (±30%), reflux rate (±22%), and reboiler heat duty (±150%), the top and bottom concentration of methanol were measured. A frequency response analysis for the above step response was carried out using Bode diagram, the log modulus and the phase angle were used to analyze the process model. A Matlab progra
... Show MoreThis research aims to develop transdermal patches of Ondansetron hydrochloride (OSH) with different types of polymers, ethyl cellulose and, polyvinyl pyrrolidone k30 in a ratio (3:0.5,3:1,3:2,2:1,1:1) with propylene glycol 20%w/w as a plasticizer. Prepared transdermal patches were evaluated for physical properties. The compatibility between the drug and excipients was studied by Differential scanning calorimetry (DSC), where there is no interaction between the drug and polymers. From the statistical study, there is a statistical difference between all the prepared formulations p<0.05. In-vitro Release study of transdermal patches was performed by using a paddle over the disc. The release profile of OSH follow
... Show MoreMefenamic acid was esterified with starchwith[1:1] Molar ratio, as drug substituted with natural polymer, to prolongthe period of hydrolysis of drug polymer with other advantages. The new prodrug starch was characterized by FT-IR and UV-Visible and 1H-NMR spectroscopies. The physical properties were studied and controlled drug release was studied in different pH values at 37oC. The stability of drug was carried out by measuring the absorbance of mefenamic starch which hydrolyzed in HCl solution of pH 1.1 (artificial gastric fluid) and phosphate buffer of pH 7.4 (simulating intestinal fluid SIF) at 37oC for several days. The thermal analysis such as DSC was studied.
Began the process of re-engineering processes in the private sector as a way to assist organizations in re-thinking how to run the business in order to improve production processes and reduce operational cost, to get to compete on a global level. That was a major restructuring by further evolution in the use of technology to support innovative operations.
Entered the technology in all areas of life and different regulations, This led to use as a change in all aspects The companies achieved success and progress today through the use of resources so as to ensure the wishes of the customers and their needs, and the requirements of the market primarily, Which is reflected on the basis of building strate
... Show MoreWhile the impact of the fourth Industrial Revolution on the economy keeps accelerating, the signs of the fifth industrial revolution, whose key is innovation and creativity started to evolve. However, the challenge of achieving sustainable development and its goals remains faced by the global organizations; In this situation, Islamic banks are exposed to many challenges among which is the challenge of keeping themselves abreast of the latest developments in the modern technology which in turn is a tool for continuity and competition. On the flip side, to avoid the negative impact that these changes can have such as an increased gap between financial innovations and the requirements of sustainable development. Islamic banks in the
... Show MoreA variety of single-engine driven files and inematics have been introduced to improve the clinical performance of NiTi rotary files. The purpose of this in vitro study was to measure and compare the incidence of dentinal defects after root canal preparation with different single file systems.
